57 Comparison of Upgraded Versus de-novo Cardiac Resynchronisation Therapy (CRT) Devices on Cardiovascular Outcomes and Response. (6th June 2015)
- Record Type:
- Journal Article
- Title:
- 57 Comparison of Upgraded Versus de-novo Cardiac Resynchronisation Therapy (CRT) Devices on Cardiovascular Outcomes and Response. (6th June 2015)
- Main Title:
- 57 Comparison of Upgraded Versus de-novo Cardiac Resynchronisation Therapy (CRT) Devices on Cardiovascular Outcomes and Response
- Authors:
- McAloon, Christopher
Heining, Domonic
Barker, Jethro
Atherton, Gavin
Anderson, Benjamin
Osman, Faizel - Abstract:
- Abstract : Background: CRT is an effective therapy in HF. Pacemakers and defibrillators are implanted for arrhythmogenic indications. Pacing dependency can induce HF and is an established CRT upgrade criterion [LVEF <35% and ventricular pacing >40%]. We aimed to compare cardiovascular outcomes between upgraded and de-novo CRT's. Methodology: A retrospective study of all consecutive CRT implants over five years (Jan 2009 – Dec 2013) in a UK tertiary centre. Data was collected on baseline demographics, co-morbidities and indications (NYHA class, ECG, echocardiogram). Comparisons were made for these outcomes: acute response [<2 mths], long-term response [>2 mths], all-cause mortality and first hospitalisation. CRT response was defined as >1 NYHA class increase. Results: 373 CRT implants were performed (79 upgrades). Upgrade and de-novo patients were matched for all comorbidities. Table 1 demonstrates baseline demographics, indications and CRT response. A Kaplan-Meier analysis was performed on all-cause mortality and time to first hospitalisation, with three year rates demonstrated in the table. A significantly worse long-term response (p 0.002) and all-cause mortality (p 0.043) was demonstrated for upgrade patients. Conclusion: Upgraded CRT patients have a worse long-term response and higher all-cause mortality. The potential worse outcome for upgrade patients should be considered before implant.
- Is Part Of:
- Heart. Volume 101(2015)Supplement 4
- Journal:
- Heart
- Issue:
- Volume 101(2015)Supplement 4
- Issue Display:
- Volume 101, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 101
- Issue:
- 4
- Issue Sort Value:
- 2015-0101-0004-0000
- Page Start:
- A31
- Page End:
- A32
- Publication Date:
- 2015-06-06
- Subjects:
- Cardiac Resynchronisation Therapy -- Heart Failure -- Arrhythmia
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2015-308066.57 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19883.xml