P159 Validation of the VitaloJAK™ 24 Hour Ambulatory Cough Monitor. (19th November 2012)
- Record Type:
- Journal Article
- Title:
- P159 Validation of the VitaloJAK™ 24 Hour Ambulatory Cough Monitor. (19th November 2012)
- Main Title:
- P159 Validation of the VitaloJAK™ 24 Hour Ambulatory Cough Monitor
- Authors:
- McGuinness, K
Holt, K
Dockry, R
Smith, J - Abstract:
- Abstract : Introduction: Development of novel treatments for cough and its management are hampered by the lack of well validated objective cough frequency methodologies. Previous validations have been performed over limited time periods or in laboratory conditions not always representative of typical usage. We describe the rigorous validation of a semi-automated 24 hour ambulatory cough monitoring system (Vitalojak; Vitalograph; Buckinghamshire, England) operating in a manner which completely replicates routine practise. Methods: In total 10 (4 female) patients (mean age 60.4 years [SD ±14.1] including 6 chronic cough, 2 asthma, 1 COPD and 1 healthy control underwent full 24 Hour ambulatory monitoring (VitaloJAK™). These recordings were manually counted by trained cough counters who also recorded the time at which each cough occurred. These 24 hour recordings were then compressed using custom designed compression software and the sensitivity to cough and the reduced file times were determined. Importantly in each case we confirmed that cough sounds identified in the compressed files were the same sounds identified by the trained manual cough counters in the full 24 hour recording. We tested the software algorithm using three distinct compression levels (1, 2 and 3). Results: All results are presented as median (IQR). Sensitivities to cough (%) for compression levels 1, 2 and 3 are 100(100, 100), 100(99.53, 100) and 99.92(99.33, 100) and for reduced file times (minutes) 65.89Abstract : Introduction: Development of novel treatments for cough and its management are hampered by the lack of well validated objective cough frequency methodologies. Previous validations have been performed over limited time periods or in laboratory conditions not always representative of typical usage. We describe the rigorous validation of a semi-automated 24 hour ambulatory cough monitoring system (Vitalojak; Vitalograph; Buckinghamshire, England) operating in a manner which completely replicates routine practise. Methods: In total 10 (4 female) patients (mean age 60.4 years [SD ±14.1] including 6 chronic cough, 2 asthma, 1 COPD and 1 healthy control underwent full 24 Hour ambulatory monitoring (VitaloJAK™). These recordings were manually counted by trained cough counters who also recorded the time at which each cough occurred. These 24 hour recordings were then compressed using custom designed compression software and the sensitivity to cough and the reduced file times were determined. Importantly in each case we confirmed that cough sounds identified in the compressed files were the same sounds identified by the trained manual cough counters in the full 24 hour recording. We tested the software algorithm using three distinct compression levels (1, 2 and 3). Results: All results are presented as median (IQR). Sensitivities to cough (%) for compression levels 1, 2 and 3 are 100(100, 100), 100(99.53, 100) and 99.92(99.33, 100) and for reduced file times (minutes) 65.89 (62.40, 83.07), 43.21 (35.94, 57.23) and 26.30 (25.07, 46.81) respectively (Table 1 ). Conclusions: The vitaloJAK™ is a reliable, robust and efficient tool for the objective measurement of cough frequency. Importantly it reduces 24 hour recordings by up to 98% whilst preserving close to 100% of recorded cough sounds. This development facilitates efficient and speedy manual cough counting and the level of compression achieved represents significant progress towards fully automated cough monitoring. … (more)
- Is Part Of:
- Thorax. Volume 67(2012)Supplement 2
- Journal:
- Thorax
- Issue:
- Volume 67(2012)Supplement 2
- Issue Display:
- Volume 67, Issue 2 (2012)
- Year:
- 2012
- Volume:
- 67
- Issue:
- 2
- Issue Sort Value:
- 2012-0067-0002-0000
- Page Start:
- A131
- Page End:
- A131
- Publication Date:
- 2012-11-19
- Subjects:
- Chest -- Diseases -- Periodicals
Thorax
Chest -- Diseases
Periodicals
Periodicals
617.54 - Journal URLs:
- http://thorax.bmjjournals.com/contents-by-date.0.shtml ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/thoraxjnl-2012-202678.220 ↗
- Languages:
- English
- ISSNs:
- 0040-6376
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19882.xml