Assessment of occupational exposure from shielded and unshielded syringes for clinically relevant positron emission tomography (PET) isotopes—a Monte Carlo approach using EGSnrc. (11th November 2021)
- Record Type:
- Journal Article
- Title:
- Assessment of occupational exposure from shielded and unshielded syringes for clinically relevant positron emission tomography (PET) isotopes—a Monte Carlo approach using EGSnrc. (11th November 2021)
- Main Title:
- Assessment of occupational exposure from shielded and unshielded syringes for clinically relevant positron emission tomography (PET) isotopes—a Monte Carlo approach using EGSnrc
- Authors:
- McCann, Ann
León Vintró, Luis
Cournane, Seán
Lucey, Julie - Abstract:
- Abstract: 18 F has been the most widely used radionuclide in positron emission tomography (PET) facilities over the last few decades. However, increased interest in novel PET tracers, theranostics and immuno-PET has led to significant growth in clinically used positron-emitting radionuclides. The decay schemes of each of these radioisotopes are markedly different from 18 F, with different endpoint energies for the emitted positrons and, in some cases, additional high energy gamma radiation. This has implications for the occupational exposure of personnel involved in the manipulation and dispensing of PET radiopharmaceuticals. The EGSnrc Monte Carlo simulation software was used to estimate the doses to extremities in contact with unshielded and shielded syringes containing 64 Cu, 18 F, 11 C, 13 N, 15 O, 68 Ga and 89 Zr, respectively. Dose rates at various distances from the syringe were also modelled, with dose rates reported in terms of eye (Hp(3)), skin equivalent (Hp(0.07)) and deep (Hp(10)) doses. The composition and geometry of the simulated syringe shields were based on a selection of commercially available PET shields. Experimental dose rate measurements were performed for validation purposes where possible. Contact skin dose rates for all isotopes, except for 64 Cu, were found to be higher than 18 F for the unshielded syringe. The addition of a shield resulted in approximately equal contact skin dose rates for nearly all isotopes, for each shield type, with theAbstract: 18 F has been the most widely used radionuclide in positron emission tomography (PET) facilities over the last few decades. However, increased interest in novel PET tracers, theranostics and immuno-PET has led to significant growth in clinically used positron-emitting radionuclides. The decay schemes of each of these radioisotopes are markedly different from 18 F, with different endpoint energies for the emitted positrons and, in some cases, additional high energy gamma radiation. This has implications for the occupational exposure of personnel involved in the manipulation and dispensing of PET radiopharmaceuticals. The EGSnrc Monte Carlo simulation software was used to estimate the doses to extremities in contact with unshielded and shielded syringes containing 64 Cu, 18 F, 11 C, 13 N, 15 O, 68 Ga and 89 Zr, respectively. Dose rates at various distances from the syringe were also modelled, with dose rates reported in terms of eye (Hp(3)), skin equivalent (Hp(0.07)) and deep (Hp(10)) doses. The composition and geometry of the simulated syringe shields were based on a selection of commercially available PET shields. Experimental dose rate measurements were performed for validation purposes where possible. Contact skin dose rates for all isotopes, except for 64 Cu, were found to be higher than 18 F for the unshielded syringe. The addition of a shield resulted in approximately equal contact skin dose rates for nearly all isotopes, for each shield type, with the exception of 89 Zr which was notably higher. Dose rate constants ( µ Gy/MBq.hr) for a range of PET isotopes and shields are presented and their significance discussed. … (more)
- Is Part Of:
- Journal of radiological protection. Volume 41:Number 4(2021)
- Journal:
- Journal of radiological protection
- Issue:
- Volume 41:Number 4(2021)
- Issue Display:
- Volume 41, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 41
- Issue:
- 4
- Issue Sort Value:
- 2021-0041-0004-0000
- Page Start:
- 1060
- Page End:
- 1074
- Publication Date:
- 2021-11-11
- Subjects:
- Hp(10) -- Hp(0.07) -- Hp(3) -- radiation protection -- syringe shield -- occupational exposure -- EGSnrc
Radiation -- Safety measures -- Periodicals
Health Physics -- Periodicals
Radiation Monitoring -- Periodicals
Radiation Protection -- Periodicals
Rayonnement -- Sécurité -- Mesures -- Périodiques
Electronic journals
Fulltext
Internet Resource
Periodical
363.179905 - Journal URLs:
- http://www.iop.org/EJ/journal/JRP ↗
http://iopscience.iop.org/0952-4746/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6498/ac0df5 ↗
- Languages:
- English
- ISSNs:
- 0952-4746
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19851.xml