P028 The Nox A1 ambulatory system is reliable when self-applied. (7th October 2021)
- Record Type:
- Journal Article
- Title:
- P028 The Nox A1 ambulatory system is reliable when self-applied. (7th October 2021)
- Main Title:
- P028 The Nox A1 ambulatory system is reliable when self-applied
- Authors:
- Cuesta, R
Roebuck, T
Ho, S
Naughton, M
McDermott, E
VanBraak, E
Beranek, R
Davis, S
Spiteri, M
Dabscheck, E
Miller, B
Yu, C - Abstract:
- Abstract: Background: Home Sleep Apnea Tests (HSAT) increases access to SDB diagnostic testing (Safadi, 2014). A previous study defined a reliable HSAT if: ≥4hours total recording time, an intelligible position signal and respiratory effort, airflow and oximetry for at least 80% of the night were recorded, however, admits no standardized criteria in the literature (Domingo, 2010). Aim: To test the reliability of a self-applied HSAT using the Nox-A1 ambulatory system (NOX Medical, Iceland). Method: Patients self-applied the HSAT guided by industry produced video and written instructions. Signals for the HSAT included; two electro-occulagrams (EOG), two sub-mental electromyograms (EMG), a single modified frontal encephalogram (EEG), a lead I ECG, single leg anterior tibialis EMG, chest and abdominal inductance respiratory effort, nasal pressure airflow, WristOx 2 3150 SpO2 (Nonin Medical, Inc., USA) and 3-D accelerometer and body position sensor. Analysed with ProFusion PSG 4 (Compumedics Limited, Australia) after importing data into Nexus. 33 consecutive studies were recorded during lock-down. Recording satisfactory if SpO2 signal and EEG present >80% of study, it was considered a failure if doctor requested test repeat. Results: 33 subjects, age 43.1 ± 13.7 years, BMI 27.4 ± 6.0 kg/m2, 66.6% male. 81.8% of studies satisfactory. 6% of studies needed a repeat in-lab PSG due to 1) loss of oximetry & EEG and 2) loss of EEG Discussion: 6% doctor request repeat in-lab PSG isAbstract: Background: Home Sleep Apnea Tests (HSAT) increases access to SDB diagnostic testing (Safadi, 2014). A previous study defined a reliable HSAT if: ≥4hours total recording time, an intelligible position signal and respiratory effort, airflow and oximetry for at least 80% of the night were recorded, however, admits no standardized criteria in the literature (Domingo, 2010). Aim: To test the reliability of a self-applied HSAT using the Nox-A1 ambulatory system (NOX Medical, Iceland). Method: Patients self-applied the HSAT guided by industry produced video and written instructions. Signals for the HSAT included; two electro-occulagrams (EOG), two sub-mental electromyograms (EMG), a single modified frontal encephalogram (EEG), a lead I ECG, single leg anterior tibialis EMG, chest and abdominal inductance respiratory effort, nasal pressure airflow, WristOx 2 3150 SpO2 (Nonin Medical, Inc., USA) and 3-D accelerometer and body position sensor. Analysed with ProFusion PSG 4 (Compumedics Limited, Australia) after importing data into Nexus. 33 consecutive studies were recorded during lock-down. Recording satisfactory if SpO2 signal and EEG present >80% of study, it was considered a failure if doctor requested test repeat. Results: 33 subjects, age 43.1 ± 13.7 years, BMI 27.4 ± 6.0 kg/m2, 66.6% male. 81.8% of studies satisfactory. 6% of studies needed a repeat in-lab PSG due to 1) loss of oximetry & EEG and 2) loss of EEG Discussion: 6% doctor request repeat in-lab PSG is comparable to a study (Lloberes, 2001) of partially self-applied HSAT. Demonstrated good reliability with this self-applied COVID-safe method of HSAT. … (more)
- Is Part Of:
- Sleep advances. Volume 2:Supplement 1(2021)
- Journal:
- Sleep advances
- Issue:
- Volume 2:Supplement 1(2021)
- Issue Display:
- Volume 2, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 2
- Issue:
- 1
- Issue Sort Value:
- 2021-0002-0001-0000
- Page Start:
- A30
- Page End:
- A30
- Publication Date:
- 2021-10-07
- Subjects:
- Sleep disorders -- Periodicals
Circadian rhythms -- Periodicals
616.8498 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/sleepadvances/issue ↗ - DOI:
- 10.1093/sleepadvances/zpab014.076 ↗
- Languages:
- English
- ISSNs:
- 2632-5012
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19858.xml