Screening for paroxysmal atrial fibrillation in primary care using Holter monitoring and intermittent, ambulatory single-lead electrocardiography. (15th December 2021)
- Record Type:
- Journal Article
- Title:
- Screening for paroxysmal atrial fibrillation in primary care using Holter monitoring and intermittent, ambulatory single-lead electrocardiography. (15th December 2021)
- Main Title:
- Screening for paroxysmal atrial fibrillation in primary care using Holter monitoring and intermittent, ambulatory single-lead electrocardiography
- Authors:
- Karregat, Evert P.M.
Gurp, Nicole Verbiest-van
Bouwman, Anne C.
Uittenbogaart, Steven B.
Himmelreich, Jelle C.L.
Lucassen, Wim A.M.
Krul, Sébastien P.J.
van Kesteren, Henri A.M.
Luermans, Justin G.L.M.
van Weert, Henk C.P.M.
Stoffers, Henri E.J.H. - Abstract:
- Abstract: Background : Timely detection of atrial fibrillation (AF) is important because of its increased risk of thrombo-embolic events. Single time point screening interventions fall short in detection of paroxysmal AF, which requires prolonged electrocardiographic monitoring, usually using a Holter. However, traditional 24-48 h Holter monitoring is less appropriate for screening purposes because of its low diagnostic yield. Intermittent, ambulatory screening using a single-lead electrocardiogram (1 L-ECG) device can offer a more efficient alternative. Methods : Primary care patients of ≥65 years participated in an opportunistic screening study for AF. We invited patients with a negative 12 L-ECG to wear a Holter monitor for two weeks and to use a MyDiagnostick 1 L-ECG device thrice daily. We report the yield of paroxysmal AF found by Holter monitoring and calculate the diagnostic accuracy of the 1 L-ECG device's built-in AF detection algorithm with the Holter monitor as reference standard. Results : We included 270 patients, of whom four had AF in a median of 8.0 days of Holter monitoring, a diagnostic yield of 1.5% (95%-CI: 0.4–3.8%). In 205 patients we performed simultaneous 1 L-ECG screening. For diagnosing AF based on the 1 L-ECG device's AF detection algorithm, sensitivity was 66.7% (95%-CI: 9.4–99.2%), specificity 68.8% (95%-CI: 61.9–75.1%), positive predictive value 3.1% (95%-CI: 1.4–6.8%) and negative predictive value 99.3% (95%-CI: 96.6–99.9%). Conclusion : WeAbstract: Background : Timely detection of atrial fibrillation (AF) is important because of its increased risk of thrombo-embolic events. Single time point screening interventions fall short in detection of paroxysmal AF, which requires prolonged electrocardiographic monitoring, usually using a Holter. However, traditional 24-48 h Holter monitoring is less appropriate for screening purposes because of its low diagnostic yield. Intermittent, ambulatory screening using a single-lead electrocardiogram (1 L-ECG) device can offer a more efficient alternative. Methods : Primary care patients of ≥65 years participated in an opportunistic screening study for AF. We invited patients with a negative 12 L-ECG to wear a Holter monitor for two weeks and to use a MyDiagnostick 1 L-ECG device thrice daily. We report the yield of paroxysmal AF found by Holter monitoring and calculate the diagnostic accuracy of the 1 L-ECG device's built-in AF detection algorithm with the Holter monitor as reference standard. Results : We included 270 patients, of whom four had AF in a median of 8.0 days of Holter monitoring, a diagnostic yield of 1.5% (95%-CI: 0.4–3.8%). In 205 patients we performed simultaneous 1 L-ECG screening. For diagnosing AF based on the 1 L-ECG device's AF detection algorithm, sensitivity was 66.7% (95%-CI: 9.4–99.2%), specificity 68.8% (95%-CI: 61.9–75.1%), positive predictive value 3.1% (95%-CI: 1.4–6.8%) and negative predictive value 99.3% (95%-CI: 96.6–99.9%). Conclusion : We found a low diagnostic yield of paroxysmal AF using Holter monitoring in elderly primary care patients with a negative 12 L-ECG. The diagnostic accuracy of an intermittently, ambulatory used MyDiagnostick 1 L-ECG device as interpreted by its built-in AF detection algorithm is limited. Highlights: The diagnostic yield of Holter monitoring in screening for paroxysmal AF is low. The diagnostic accuracy of ambulatory MyDiagnostick 1 L-ECG recordings is limited. Cardiologists cannot reliably diagnose AF on ambulatory MyDiagnostick 1 L-ECG's. Algorithm-positive ambulatory MyDiagnostick 1 L-ECG's are often uninterpretable. … (more)
- Is Part Of:
- International journal of cardiology. Volume 345(2021)
- Journal:
- International journal of cardiology
- Issue:
- Volume 345(2021)
- Issue Display:
- Volume 345, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 345
- Issue:
- 2021
- Issue Sort Value:
- 2021-0345-2021-0000
- Page Start:
- 41
- Page End:
- 46
- Publication Date:
- 2021-12-15
- Subjects:
- Atrial fibrillation -- Screening -- Electrocardiography -- Prevalence -- Holter monitoring -- Diagnostic accuracy
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2021.10.021 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19867.xml