The IAEA remote and automated quality control methodology for radiography and mammography. Issue 11 (8th October 2021)
- Record Type:
- Journal Article
- Title:
- The IAEA remote and automated quality control methodology for radiography and mammography. Issue 11 (8th October 2021)
- Main Title:
- The IAEA remote and automated quality control methodology for radiography and mammography
- Authors:
- Mora, Patricia
Pfeiffer, Douglas
Zhang, Gouzhi
Bosmans, Hilde
Delis, Harry
Razi, Zahra
Arreola, Manuel
Tsapaki, Virginia - Abstract:
- Abstract: Radiography remains the most widely used imaging modality throughout the world. Additionally, while it has been demonstrated that a quality control (QC) program, especially in mammography, improves image quality, weekly technologist QC testing might be lacking even where there is clinical qualified medical physicist (CQMP) support. Therefore, the International Atomic Energy Agency (IAEA) developed simple QC phantoms that can easily be used on a regular basis (daily/weekly) for radiography and mammography. These are simple in design and use materials that are easily accessible in most parts of the world. A software application is also developed that automatically analyzes images and Digital Imaging and Communications in Medicine (DICOM) header information. It exports data to a comma‐separated values (CSV) file that is read by a Microsoft Excel® spreadsheet for documentation and graphical analysis. The phantom and the software were tested in four institutions (in Costa Rica and the United States of America) both on computed radiography and direct digital mammography and radiography systems. Data were collected over a 3‐year period. No corrective actions were taken on the data, but service was performed on two of the units. Results demonstrated noise that could be attributed to suboptimal placement of the phantom and incorrect data being put into the DICOM header. Preliminary evaluation of the IAEA methodology has demonstrated that it can provide meaningful QC dataAbstract: Radiography remains the most widely used imaging modality throughout the world. Additionally, while it has been demonstrated that a quality control (QC) program, especially in mammography, improves image quality, weekly technologist QC testing might be lacking even where there is clinical qualified medical physicist (CQMP) support. Therefore, the International Atomic Energy Agency (IAEA) developed simple QC phantoms that can easily be used on a regular basis (daily/weekly) for radiography and mammography. These are simple in design and use materials that are easily accessible in most parts of the world. A software application is also developed that automatically analyzes images and Digital Imaging and Communications in Medicine (DICOM) header information. It exports data to a comma‐separated values (CSV) file that is read by a Microsoft Excel® spreadsheet for documentation and graphical analysis. The phantom and the software were tested in four institutions (in Costa Rica and the United States of America) both on computed radiography and direct digital mammography and radiography systems. Data were collected over a 3‐year period. No corrective actions were taken on the data, but service was performed on two of the units. Results demonstrated noise that could be attributed to suboptimal placement of the phantom and incorrect data being put into the DICOM header. Preliminary evaluation of the IAEA methodology has demonstrated that it can provide meaningful QC data that are sensitive to changes in the imaging systems. Care must be taken at implementation to properly train personnel and ensure that the image data, including the DICOM header, are being correctly transmitted. The methodology gives the opportunity for a single CQMP to provide QC services even to remote sites where travel is prohibitive, and it is feasible and easy to implement. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 22:Issue 11(2021)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 22:Issue 11(2021)
- Issue Display:
- Volume 22, Issue 11 (2021)
- Year:
- 2021
- Volume:
- 22
- Issue:
- 11
- Issue Sort Value:
- 2021-0022-0011-0000
- Page Start:
- 126
- Page End:
- 142
- Publication Date:
- 2021-10-08
- Subjects:
- automatic -- detectability index -- quality control -- remote support
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13431 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19861.xml