A randomized crossover pilot study comparing the efficacy of an auto-demand oxygen delivery system with that of a conventional demand oxygen delivery system in patients with chronic respiratory failure. Issue 37 (17th September 2021)
- Record Type:
- Journal Article
- Title:
- A randomized crossover pilot study comparing the efficacy of an auto-demand oxygen delivery system with that of a conventional demand oxygen delivery system in patients with chronic respiratory failure. Issue 37 (17th September 2021)
- Main Title:
- A randomized crossover pilot study comparing the efficacy of an auto-demand oxygen delivery system with that of a conventional demand oxygen delivery system in patients with chronic respiratory failure
- Authors:
- Otoshi, Takehiro
Nagano, Tatsuya
Murakami, Sae
Omori, Takashi
Hazama, Daisuke
Katsurada, Naoko
Yamamoto, Masatsugu
Tachihara, Motoko
Nishimura, Yoshihiro
Kobayashi, Kazuyuki - Other Names:
- Fröhlich. Eleonore section editor.
- Abstract:
- Abstract: Introduction: : When using portable oxygen, a demand oxygen delivery system (DODS), which senses the beginning of inhalation and delivers a bolus of oxygen, is often used. However, conventional DODS may not supply sufficient oxygen when reduced tidal flow fails to trigger the flow sensor. Recently, "auto-DODS, " which detects the negative pressure of inhalation and switches among 3 trigger sensitivity levels ( standard, high, and extra high ), has been developed to improve the efficacy of oxygenation. An auto-DODS can also supply pulsed-flow oxygen when it detects apnea, whereas a conventional DODS has only standard sensitivity. This randomized, open-label, crossover pilot study compared the performance of an auto-DODS with that of a conventional DODS. Methods: : We recruited patients with chronic obstructive pulmonary disease (COPD) or interstitial pneumonia receiving long-term oxygen therapy. Interventions were performed on 2 different days for each participant. On each day, an auto-DODS or a conventional DODS were tested at rest for 30 minutes and during the 6-minute walk test. The primary outcome was mean oxygen saturation (SpO2). Secondary outcomes were the ratios of time for each sensitivity level and pulsed-flow oxygen when using the auto-DODS, total time desaturated below SpO2 90%, percentage of time desaturated below SpO2 90%, minimum SpO2, mean and maximum pulse rate, six-minute walk distance, recovery time after 6-minute walk test, modified Borg scale,Abstract: Introduction: : When using portable oxygen, a demand oxygen delivery system (DODS), which senses the beginning of inhalation and delivers a bolus of oxygen, is often used. However, conventional DODS may not supply sufficient oxygen when reduced tidal flow fails to trigger the flow sensor. Recently, "auto-DODS, " which detects the negative pressure of inhalation and switches among 3 trigger sensitivity levels ( standard, high, and extra high ), has been developed to improve the efficacy of oxygenation. An auto-DODS can also supply pulsed-flow oxygen when it detects apnea, whereas a conventional DODS has only standard sensitivity. This randomized, open-label, crossover pilot study compared the performance of an auto-DODS with that of a conventional DODS. Methods: : We recruited patients with chronic obstructive pulmonary disease (COPD) or interstitial pneumonia receiving long-term oxygen therapy. Interventions were performed on 2 different days for each participant. On each day, an auto-DODS or a conventional DODS were tested at rest for 30 minutes and during the 6-minute walk test. The primary outcome was mean oxygen saturation (SpO2). Secondary outcomes were the ratios of time for each sensitivity level and pulsed-flow oxygen when using the auto-DODS, total time desaturated below SpO2 90%, percentage of time desaturated below SpO2 90%, minimum SpO2, mean and maximum pulse rate, six-minute walk distance, recovery time after 6-minute walk test, modified Borg scale, comfort, and discomfort index. Results: : When using the auto-DODS at rest, a high or extra high sensitivity level was observed in addition to standard sensitivity in 6 of 8 participants. During the 6-minute walk test, only standard sensitivity was observed in 6 participants. Mean SpO2 differences between the auto-DODS and conventional DODS at rest and during the 6-minute walk test were −0.6 [−4.5, 3.4] and 0.0 [−2.5, 2.5] ([95% confidence interval]), respectively, neither of which were significant ( P = .73 and P = .99). There were no significant differences in secondary outcomes. There were no adverse events when using the auto-DODS. Conclusions: : This study showed that the auto-DODS did not show superiority in oxygenation either at rest or during exercise compared to a conventional DODS. The auto-DODS was shown to supply oxygen safely and detect inhalations with various trigger sensitivities. Abstract : Supplemental Digital Content is available in the text … (more)
- Is Part Of:
- Medicine. Volume 100:Issue 37(2021)
- Journal:
- Medicine
- Issue:
- Volume 100:Issue 37(2021)
- Issue Display:
- Volume 100, Issue 37 (2021)
- Year:
- 2021
- Volume:
- 100
- Issue:
- 37
- Issue Sort Value:
- 2021-0100-0037-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-09-17
- Subjects:
- chronic respiratory failure -- demand oxygen delivery system -- portable oxygen concentrator -- trigger sensitivity
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000027191 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19844.xml