A highly sensitive multiplex immunoassay for inflammatory cytokines in dried blood spots. Issue 6 (31st December 2020)
- Record Type:
- Journal Article
- Title:
- A highly sensitive multiplex immunoassay for inflammatory cytokines in dried blood spots. Issue 6 (31st December 2020)
- Main Title:
- A highly sensitive multiplex immunoassay for inflammatory cytokines in dried blood spots
- Authors:
- McDade, Thomas W.
Miller, Aaron
Tran, Tina T.
Borders, Ann E. B.
Miller, Greg - Abstract:
- Abstract: Objectives: Inflammatory cytokines are key regulators of inflammation, but current measurement approaches require venous blood to quantify low circulating concentrations associated with chronic, low‐grade inflammation. This article describes a highly sensitive multiplex immunoassay protocol for the measurement of IL6, IL8, IL10, and TNFα in finger stick dried blood spot (DBS) samples. Methods: The protocol uses a multiplex electrochemiluminescent immunoassay platform. The following measures of assay performance were evaluated: reliability (inter‐assay percent coefficient of variation; %CV), precision (intra‐assay %CV), lower limit of detection (LLD), linearity of dilution, and agreement with results from matched plasma samples. Results: Analysis of three control samples across the assay range indicated an acceptable level of precision and reliability for each cytokine. Linearity of dilution returned average values that ranged from 104.1 to 127.6% of expected. Lower limits of detection for IL6, IL8, and IL10 were <0.5, and <1.0 pg/ml for TNFα. Level of agreement in results between matched DBS and plasma samples was high for all cytokines except for IL8. Conclusions: Finger stick DBS sampling provides a viable alternative to venipuncture for the quantification of IL6, IL10, and TNFα at low concentrations associated with chronic inflammation. The presence of red blood cells may interfere with the quantification of IL8 in DBS. In facilitating blood collection inAbstract: Objectives: Inflammatory cytokines are key regulators of inflammation, but current measurement approaches require venous blood to quantify low circulating concentrations associated with chronic, low‐grade inflammation. This article describes a highly sensitive multiplex immunoassay protocol for the measurement of IL6, IL8, IL10, and TNFα in finger stick dried blood spot (DBS) samples. Methods: The protocol uses a multiplex electrochemiluminescent immunoassay platform. The following measures of assay performance were evaluated: reliability (inter‐assay percent coefficient of variation; %CV), precision (intra‐assay %CV), lower limit of detection (LLD), linearity of dilution, and agreement with results from matched plasma samples. Results: Analysis of three control samples across the assay range indicated an acceptable level of precision and reliability for each cytokine. Linearity of dilution returned average values that ranged from 104.1 to 127.6% of expected. Lower limits of detection for IL6, IL8, and IL10 were <0.5, and <1.0 pg/ml for TNFα. Level of agreement in results between matched DBS and plasma samples was high for all cytokines except for IL8. Conclusions: Finger stick DBS sampling provides a viable alternative to venipuncture for the quantification of IL6, IL10, and TNFα at low concentrations associated with chronic inflammation. The presence of red blood cells may interfere with the quantification of IL8 in DBS. In facilitating blood collection in nonclinical settings this method can advance scientific understandings of how social and ecological contexts shape immune function and health over the life course. … (more)
- Is Part Of:
- American journal of human biology. Volume 33:Issue 6(2021)
- Journal:
- American journal of human biology
- Issue:
- Volume 33:Issue 6(2021)
- Issue Display:
- Volume 33, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 33
- Issue:
- 6
- Issue Sort Value:
- 2021-0033-0006-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2020-12-31
- Subjects:
- Human biology -- Periodicals
Physical anthropology -- Periodicals
Biologie humaine -- Périodiques
Anthropologie physique -- Périodiques
612 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1520-6300 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ajhb.23558 ↗
- Languages:
- English
- ISSNs:
- 1042-0533
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0824.900000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19827.xml