Radiomics analysis of EPID measurements for patient positioning error detection in thyroid associated ophthalmopathy radiotherapy. (October 2021)
- Record Type:
- Journal Article
- Title:
- Radiomics analysis of EPID measurements for patient positioning error detection in thyroid associated ophthalmopathy radiotherapy. (October 2021)
- Main Title:
- Radiomics analysis of EPID measurements for patient positioning error detection in thyroid associated ophthalmopathy radiotherapy
- Authors:
- Zhang, Xiangbin
Dai, Guyu
Zhong, Renming
Zhou, Li
Xiao, Qing
Wang, Xuetao
Lai, Jialu
Zhao, Jianling
Li, Guangjun
Bai, Sen - Abstract:
- Highlights: Radiomics analysis of EPID measurements can classify the magnitude and directions of positioning errors. AUCs of the detection of positioning errors and directions classification were above 0.90 and 0.76, respectively. Positioning errors are detectable from EPID measurements with multifactorial error sources. High performance is achievable using a small-size sample for patients with thyroid-associated ophthalmopathy. This study is a further step toward machine learning-based positioning error detection via EPID measurements. Abstract: Purpose: Electronic portal imaging detector (EPID)-based patient positioning verification is an important component of safe radiotherapy treatment delivery. In computer simulation studies, learning-based approaches have proven to be superior to conventional gamma analysis in the detection of positioning errors. To approximate a clinical scenario, the detectability of positioning errors via EPID measurements was assessed using radiomics analysis for patients with thyroid-associated ophthalmopathy. Methods: Treatment plans of 40 patients with thyroid-associated ophthalmopathy were delivered to a solid anthropomorphic head phantom. To simulate positioning errors, combinations of 0-, 2-, and 4-mm translation errors in the left–right (LR), superior-inferior (SI), and anterior-posterior (AP) directions were introduced to the phantom. The positioning errors-induced dose differences between measured portal dose images were used to predictHighlights: Radiomics analysis of EPID measurements can classify the magnitude and directions of positioning errors. AUCs of the detection of positioning errors and directions classification were above 0.90 and 0.76, respectively. Positioning errors are detectable from EPID measurements with multifactorial error sources. High performance is achievable using a small-size sample for patients with thyroid-associated ophthalmopathy. This study is a further step toward machine learning-based positioning error detection via EPID measurements. Abstract: Purpose: Electronic portal imaging detector (EPID)-based patient positioning verification is an important component of safe radiotherapy treatment delivery. In computer simulation studies, learning-based approaches have proven to be superior to conventional gamma analysis in the detection of positioning errors. To approximate a clinical scenario, the detectability of positioning errors via EPID measurements was assessed using radiomics analysis for patients with thyroid-associated ophthalmopathy. Methods: Treatment plans of 40 patients with thyroid-associated ophthalmopathy were delivered to a solid anthropomorphic head phantom. To simulate positioning errors, combinations of 0-, 2-, and 4-mm translation errors in the left–right (LR), superior-inferior (SI), and anterior-posterior (AP) directions were introduced to the phantom. The positioning errors-induced dose differences between measured portal dose images were used to predict the magnitude and direction of positioning errors. The detectability of positioning errors was assessed via radiomics analysis of the dose differences. Three classification models—support vector machine (SVM), k-nearest neighbors (KNN), and XGBoost—were used for the detection of positioning errors (positioning errors larger or smaller than 3 mm in an arbitrary direction) and direction classification (positioning errors larger or smaller than 3 mm in a specific direction). The receiver operating characteristic curve and the area under the ROC curve (AUC) were used to evaluate the performance of classification models. Results: For the detection of positioning errors, the AUC values of SVM, KNN, and XGBoost models were all above 0.90. For LR, SI, and AP direction classification, the highest AUC values were 0.76, 0.91, and 0.80, respectively. Conclusions: Combined radiomics and machine learning approaches are capable of detecting the magnitude and direction of positioning errors from EPID measurements. This study is a further step toward machine learning-based positioning error detection during treatment delivery with EPID measurements. … (more)
- Is Part Of:
- Physica medica. Volume 90(2021)
- Journal:
- Physica medica
- Issue:
- Volume 90(2021)
- Issue Display:
- Volume 90, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 90
- Issue:
- 2021
- Issue Sort Value:
- 2021-0090-2021-0000
- Page Start:
- 1
- Page End:
- 5
- Publication Date:
- 2021-10
- Subjects:
- EPID dosimetry -- Positioning error detection -- Multifactorial error sources -- Radiomics analysis -- Machine learning
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2021.08.014 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19836.xml