Diagnostic performance of a colorimetric RT -LAMP for the identification of SARS-CoV-2: A multicenter prospective clinical evaluation in sub-Saharan Africa. (October 2021)
- Record Type:
- Journal Article
- Title:
- Diagnostic performance of a colorimetric RT -LAMP for the identification of SARS-CoV-2: A multicenter prospective clinical evaluation in sub-Saharan Africa. (October 2021)
- Main Title:
- Diagnostic performance of a colorimetric RT -LAMP for the identification of SARS-CoV-2: A multicenter prospective clinical evaluation in sub-Saharan Africa
- Authors:
- Baba, Marycelin Mandu
Bitew, Molalegne
Fokam, Joseph
Lelo, Eric Agola
Ahidjo, Ahmed
Asmamaw, Kominist
Beloumou, Grace Angong
Bulimo, Wallace Dimbuson
Buratti, Emanuele
Chenwi, Collins
Dadi, Hailu
D'Agaro, Pierlanfranco
De Conti, Laura
Fainguem, Nadine
Gadzama, Galadima
Maiuri, Paolo
Majanja, Janet
Meshack, Wadegu
Ndjolo, Alexis
Nkenfou, Celine
Oderinde, Bamidele Soji
Opanda, Silvanos Mukunzi
Segat, Ludovica
Stuani, Cristiana
Symekher, Samwel L.
Takou, Desire
Tesfaye, Kassahun
Triolo, Gianluca
Tuki, Keyru
Zacchigna, Serena
Marcello, Alessandro
… (more) - Abstract:
- Abstract : Background: Management and control of the COVID-19 pandemic caused by the severe acute respiratory syndrome coronavirus SARS-CoV-2 is critically dependent on quick and reliable identification of the virus in clinical specimens. Detection of viral RNA by a colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) is a simple, reliable and cost-effective assay, deployable in resource-limited settings (RLS). Our objective was to evaluate the intrinsic and extrinsic performances of RT-LAMP in RLS. Methods: This is a multicenter prospective observational study of diagnostic accuracy, conducted from October 2020 to February 2021 in four African Countries: Cameroon, Ethiopia, Kenya and Nigeria; and in Italy. We enroled 1657 individuals who were either COVID-19 suspect cases, or asymptomatic and presented for screening. RNA extracted from pharyngeal swabs was tested in parallel by a colorimetric RT-LAMP and by a standard real time polymerase chain reaction (RT-PCR). Findings: The sensitivity and specificity of index RT LAMP compared to standard RT-PCR on 1657 prospective specimens from infected individuals was determined. For a subset of 1292 specimens, which underwent exactly the same procedures in different countries, we obtained very high specificity (98%) and positive predictive value (PPV = 99%), while the sensitivity was 87%, with a negative predictive value NPV = 70%, Stratification of RT-PCR data showed superior sensitivity achieved withAbstract : Background: Management and control of the COVID-19 pandemic caused by the severe acute respiratory syndrome coronavirus SARS-CoV-2 is critically dependent on quick and reliable identification of the virus in clinical specimens. Detection of viral RNA by a colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) is a simple, reliable and cost-effective assay, deployable in resource-limited settings (RLS). Our objective was to evaluate the intrinsic and extrinsic performances of RT-LAMP in RLS. Methods: This is a multicenter prospective observational study of diagnostic accuracy, conducted from October 2020 to February 2021 in four African Countries: Cameroon, Ethiopia, Kenya and Nigeria; and in Italy. We enroled 1657 individuals who were either COVID-19 suspect cases, or asymptomatic and presented for screening. RNA extracted from pharyngeal swabs was tested in parallel by a colorimetric RT-LAMP and by a standard real time polymerase chain reaction (RT-PCR). Findings: The sensitivity and specificity of index RT LAMP compared to standard RT-PCR on 1657 prospective specimens from infected individuals was determined. For a subset of 1292 specimens, which underwent exactly the same procedures in different countries, we obtained very high specificity (98%) and positive predictive value (PPV = 99%), while the sensitivity was 87%, with a negative predictive value NPV = 70%, Stratification of RT-PCR data showed superior sensitivity achieved with an RT-PCR cycle threshold (Ct) below 35 (97%), which decreased to 60% above 35. Interpretation: In this field trial, RT-LAMP appears to be a reliable assay, comparable to RT-PCR, particularly with medium-high viral loads (Ct < 35). Hence, RT-LAMP can be deployed in RLS for timely management and prevention of COVID-19, without compromising the quality of output. Funding: Bill & Melinda Gates Foundation [Grant No. INV-022, 816]. … (more)
- Is Part Of:
- EClinicalMedicine. Volume 40(2021)
- Journal:
- EClinicalMedicine
- Issue:
- Volume 40(2021)
- Issue Display:
- Volume 40, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 40
- Issue:
- 2021
- Issue Sort Value:
- 2021-0040-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10
- Subjects:
- SARS-CoV-2 -- COVID-19 -- coronavirus -- reverse transcription loop-mediated isothermal amplification -- RT LAMP -- multicentre -- prospective -- Observational study -- diagnostic accuracy -- Sub-Saharan Africa -- Cameroon -- Ethiopia -- Kenya -- Nigeria -- Italy
Medicine -- Research -- Periodicals
Medical policy -- Periodicals
Clinical Medicine
Health Policy
Public Health
Medical policy
Medicine -- Research
Periodical
Electronic journals
Periodicals
613 - Journal URLs:
- https://www.sciencedirect.com/science/journal/25895370 ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.eclinm.2021.101101 ↗
- Languages:
- English
- ISSNs:
- 2589-5370
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19814.xml