Surgical Technique for Pars Plana Ahmed Glaucoma Valve Implantation in Advanced Glaucoma: The Upside-Down Technique. Issue 6 (13th June 2021)
- Record Type:
- Journal Article
- Title:
- Surgical Technique for Pars Plana Ahmed Glaucoma Valve Implantation in Advanced Glaucoma: The Upside-Down Technique. Issue 6 (13th June 2021)
- Main Title:
- Surgical Technique for Pars Plana Ahmed Glaucoma Valve Implantation in Advanced Glaucoma: The Upside-Down Technique
- Authors:
- Masuda, Yoichiro
Saito, Yuka
Oki, Tetsutaro
Hayashi, Takaaki
Takahashi, Genichiro
Nakano, Tadashi - Abstract:
- Abstract : Supplemental Digital Content is available in the text. Abstract : Précis: Ahmed glaucoma valve (AGV) implantation using the upside-down technique resulted in an aqueous humor outflow pathway, occurring primarily on the scleral side and secondarily on the conjunctival side, and was effective in treating refractory glaucoma. Purpose: To describe the AGV surgical technique, which results in changes in the primary aqueous humor outflow pathway to the scleral side (upside-down technique), and to evaluate the clinical effects and distribution of bleb fluid after surgery in patients with refractory glaucoma. Patients and Methods: In this retrospective study, the upside-down technique was used for pars plana AGV implantation in 10 eyes of 10 patients with refractory glaucoma. Surgical success was defined by complications, intraocular pressure (IOP), the glaucoma medication score, and bleb fluid distribution determined by magnetic resonance imaging. Results: Postoperatively, there were significant reductions in the IOP and medication score at 23 and 27 months, respectively ( P< 0.05). Although a transient hypertensive phase was observed in 7 patients, it was controlled without ocular massage and additional surgery. A patient who had suprachoroidal hemorrhage during surgery lost light perception 7 months after the surgery, and another patient developed hypotony at 3 and 4 months after surgery, which spontaneously improved during subsequent examinations. Magnetic resonanceAbstract : Supplemental Digital Content is available in the text. Abstract : Précis: Ahmed glaucoma valve (AGV) implantation using the upside-down technique resulted in an aqueous humor outflow pathway, occurring primarily on the scleral side and secondarily on the conjunctival side, and was effective in treating refractory glaucoma. Purpose: To describe the AGV surgical technique, which results in changes in the primary aqueous humor outflow pathway to the scleral side (upside-down technique), and to evaluate the clinical effects and distribution of bleb fluid after surgery in patients with refractory glaucoma. Patients and Methods: In this retrospective study, the upside-down technique was used for pars plana AGV implantation in 10 eyes of 10 patients with refractory glaucoma. Surgical success was defined by complications, intraocular pressure (IOP), the glaucoma medication score, and bleb fluid distribution determined by magnetic resonance imaging. Results: Postoperatively, there were significant reductions in the IOP and medication score at 23 and 27 months, respectively ( P< 0.05). Although a transient hypertensive phase was observed in 7 patients, it was controlled without ocular massage and additional surgery. A patient who had suprachoroidal hemorrhage during surgery lost light perception 7 months after the surgery, and another patient developed hypotony at 3 and 4 months after surgery, which spontaneously improved during subsequent examinations. Magnetic resonance imaging showed that the double bleb layer adjacent to the endplate tended to have more bleb fluid on the conjunctival side than on the scleral side facing the outlet (n=8; 1 to 29 mo after surgery). Conclusions: Pars plana AGV implantation using the upside-down technique was a relatively effective alternative to manage inadequate IOP control in patients with refractory glaucoma. … (more)
- Is Part Of:
- Journal of glaucoma. Volume 30:Issue 6(2021)
- Journal:
- Journal of glaucoma
- Issue:
- Volume 30:Issue 6(2021)
- Issue Display:
- Volume 30, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 30
- Issue:
- 6
- Issue Sort Value:
- 2021-0030-0006-0000
- Page Start:
- 489
- Page End:
- 496
- Publication Date:
- 2021-06-13
- Subjects:
- Ahmed glaucoma valve -- glaucoma drainage device -- refractory glaucoma -- neovascular glaucoma -- tube shunt surgery
Glaucoma -- Periodicals
617.741005 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00061198-000000000-00000 ↗
http://www.glaucomajournal.com ↗
http://journals.lww.com/glaucomajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IJG.0000000000001791 ↗
- Languages:
- English
- ISSNs:
- 1057-0829
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4996.230000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19800.xml