Head Rotation Reduces Oropharyngeal Leak Pressure of the i-gel and LMA® Supreme™ in Paralyzed, Anesthetized Patients: A Randomized Trial. (1st September 2020)
- Record Type:
- Journal Article
- Title:
- Head Rotation Reduces Oropharyngeal Leak Pressure of the i-gel and LMA® Supreme™ in Paralyzed, Anesthetized Patients: A Randomized Trial. (1st September 2020)
- Main Title:
- Head Rotation Reduces Oropharyngeal Leak Pressure of the i-gel and LMA® Supreme™ in Paralyzed, Anesthetized Patients: A Randomized Trial
- Authors:
- Chaki, Tomohiro
Tachibana, Shunsuke
Kumita, Sho
Sato, Honami
Hamada, Kosuke
Tokinaga, Yasuyuki
Yamakage, Michiaki - Abstract:
- Abstract : BACKGROUND: Second-generation supraglottic airway (SGA) devices are useful for airway management during positive pressure ventilation in general anesthesia and emergency medicine. In some clinical settings, such as the anesthetic management of awake craniotomy, SGAs are used in the head-rotated position, which is required for exposure of the surgical field, although this position sometimes worsens the efficiency of mechanical ventilation with SGAs. In this study, we investigated and compared the influence of head rotation on oropharyngeal leak pressures (OPLP) of the i-gel and LMA® Supreme™, which are second-generation SGA devices. METHODS: Patients who underwent elective surgery under general anesthesia were enrolled in this study and randomly divided into i-gel or LMA Supreme groups. After induction of anesthesia with muscle relaxation, the i-gel or LMA Supreme was inserted according to computerized randomization. The primary outcome was the OPLP at 0°, 30°, and 60° head rotation. The secondary outcomes were the maximum airway pressure and expiratory tidal volume when patients were mechanically ventilated using a volume-controlled ventilation mode with a tidal volume of 10 mL/kg (ideal body weight), ventilation score, and fiber-optic views of vocal cords. RESULTS: Thirty-four and 36 participants were included in the i-gel and LMA Supreme groups, respectively. The OPLPs of the i-gel and LMA Supreme significantly decreased as the head rotation angle increasedAbstract : BACKGROUND: Second-generation supraglottic airway (SGA) devices are useful for airway management during positive pressure ventilation in general anesthesia and emergency medicine. In some clinical settings, such as the anesthetic management of awake craniotomy, SGAs are used in the head-rotated position, which is required for exposure of the surgical field, although this position sometimes worsens the efficiency of mechanical ventilation with SGAs. In this study, we investigated and compared the influence of head rotation on oropharyngeal leak pressures (OPLP) of the i-gel and LMA® Supreme™, which are second-generation SGA devices. METHODS: Patients who underwent elective surgery under general anesthesia were enrolled in this study and randomly divided into i-gel or LMA Supreme groups. After induction of anesthesia with muscle relaxation, the i-gel or LMA Supreme was inserted according to computerized randomization. The primary outcome was the OPLP at 0°, 30°, and 60° head rotation. The secondary outcomes were the maximum airway pressure and expiratory tidal volume when patients were mechanically ventilated using a volume-controlled ventilation mode with a tidal volume of 10 mL/kg (ideal body weight), ventilation score, and fiber-optic views of vocal cords. RESULTS: Thirty-four and 36 participants were included in the i-gel and LMA Supreme groups, respectively. The OPLPs of the i-gel and LMA Supreme significantly decreased as the head rotation angle increased (mean difference [95% confidence interval], P value: i-gel; 0° vs 30°: 3.5 [2.2–4.8], P < .001; 30° vs 60°: 2.0 [0.6–3.5], P = .002; 0° vs 60°: 5.5 [3.3–7.8], P < .001, LMA Supreme; 0° vs 30°: 4.1 [2.6–5.5], P < .001; 30° vs 60°: 2.4 [1.1–3.7], P < .001; 0° vs 60°: 6.5 [5.1–8.0], P < .001). There were statistically significant differences in expiratory tidal volume and ventilation score between 0° and 60° in the i-gel group and in ventilation score between 30° and 60° in the LMA Supreme group. There was no statistically significant difference between the 2 devices in all outcome measures. The incidences of adverse events, such as hoarseness or sore throat, were not significantly different between i-gel and LMA Supreme. CONCLUSIONS: Head rotation to 30° and 60° reduces OPLP with both i-gel and LMA Supreme. There is no difference in OPLP between i-gel and LMA Supreme in the 3 head rotation positions. … (more)
- Is Part Of:
- Anesthesia & analgesia. Volume 132:Number 3(2021)
- Journal:
- Anesthesia & analgesia
- Issue:
- Volume 132:Number 3(2021)
- Issue Display:
- Volume 132, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 132
- Issue:
- 3
- Issue Sort Value:
- 2021-0132-0003-0000
- Page Start:
- 818
- Page End:
- 826
- Publication Date:
- 2020-09-01
- Subjects:
- Anesthesiology -- Periodicals
Anesthesia
Anesthesiology
Analgesia
Analgesics
Anesthesiology -- Periodicals
617.9605 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00000539-000000000-00000 ↗
http://journals.lww.com/anesthesia-analgesia/Pages/default.aspx ↗
http://www.anesthesia-analgesia.org ↗
http://journals.lww.com ↗ - DOI:
- 10.1213/ANE.0000000000005150 ↗
- Languages:
- English
- ISSNs:
- 0003-2999
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0900.500000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19809.xml