Stent strut thickness and acute vessel injury during percutaneous coronary interventions: an optical coherence tomography randomized clinical trial. Issue 5 (19th August 2020)
- Record Type:
- Journal Article
- Title:
- Stent strut thickness and acute vessel injury during percutaneous coronary interventions: an optical coherence tomography randomized clinical trial. Issue 5 (19th August 2020)
- Main Title:
- Stent strut thickness and acute vessel injury during percutaneous coronary interventions: an optical coherence tomography randomized clinical trial
- Authors:
- Vilchez-Tschischke, Jean Paul
Salazar, Carlos
Gil-Romero, Jorge
Mori, Ricardo
Nuñez-Gil, Ivan
Quirós, Alicia
Nombela, Luis
del Trigo, Maria
Jimenez-Quevedo, Pilar
Salinas, Pablo
Escaned, Javier
Macaya, Carlos
Gonzalo, Nieves - Abstract:
- Abstract : Aims: Compare the degree of acute vascular injury caused by a polymer-free, thin-strut drug-eluting stent (DES) to that caused by a bioresorbable polymer, thick-strut DES using optical coherence tomography (OCT). Methods and results: Fifty patients requiring nonurgent PCI were randomized to receive either a thin or a thick-strut DES. OCT was performed before and after stent implantation. OCT-based injury score (IS) after implantation was numerically higher within thick-strut stents 0.32 vs. 0.23, but the difference was NS ( P = 0.61). Edge dissections were present in 36% of the patients without differences between groups. Tissue prolapse (TP) area was larger with thin-strut stents (2.26 vs. 1.83 mm 2, P = 0.04). Stent expansion and symmetry index were similar between the two platforms (85% vs. 94%, P = 0.08; and 0.82 vs. 0.80, P = 0.25). No differences were observed in total malapposition area (1.85 mm 2 in thin-strut stents vs. 1.47 mm 2, P = 0.48). Regarding the influence of plaque-type, IS tended to be higher (non-significant) with thick strut DES in fibrocalcific plaques. Stent malapposition area was smaller in fibrous plaques, especially with thin strut stents ( P = 0.03). Conclusion: There was no difference in the extent of OCT-based vessel injury associated with thin and thick-strut DES platforms. TP was larger with the thin strut DES, potentially reflecting a deeper stent embedment in the vessel wall.
- Is Part Of:
- Coronary artery disease. Volume 32:Issue 5(2021)
- Journal:
- Coronary artery disease
- Issue:
- Volume 32:Issue 5(2021)
- Issue Display:
- Volume 32, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 32
- Issue:
- 5
- Issue Sort Value:
- 2021-0032-0005-0000
- Page Start:
- 382
- Page End:
- 390
- Publication Date:
- 2020-08-19
- Subjects:
- coronary artery disease -- drug-eluting stents -- optical coherence tomography
Coronary heart disease -- Periodicals
Coronary Disease -- Indexes
Coronary Disease -- Periodicals
616.123005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00019501-000000000-00000 ↗
http://www.coronary-artery.com/ ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1097/MCA.0000000000000943 ↗
- Languages:
- English
- ISSNs:
- 0954-6928
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3472.049000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19782.xml