Performances of NeuMoDx™, a random-access system for hepatitis B virus DNA and hepatitis C virus RNA quantification. (November 2021)
- Record Type:
- Journal Article
- Title:
- Performances of NeuMoDx™, a random-access system for hepatitis B virus DNA and hepatitis C virus RNA quantification. (November 2021)
- Main Title:
- Performances of NeuMoDx™, a random-access system for hepatitis B virus DNA and hepatitis C virus RNA quantification
- Authors:
- Besombes, Juliette
Pronier, Charlotte
Lefevre, Charles
Lagathu, Gisèle
Maillard, Anne
Grolhier, Claire
Thibault, Vincent - Abstract:
- Abstract: Objective: Monitoring of viral loads (VL) for hepatitis B and C viruses (HBV; HCV) is essential to evaluate disease progression and treatment response. Automated, random-access rapid systems are becoming standard to provide clinicians with reliable VL. The aim of this study was to evaluate the analytical performances of the recently launched NeuMoDx™ for HBV-DNA and HCV-RNA quantification. Methods: Clinical samples routinely quantified on the Beckman–Veris system were either retrospectively (frozen samples; HBV n = 178, HCV n = 249), or in parallel (fresh primary tubes; HBV n = 103, HCV n = 117) tested using NeuMoDx™. Linearity range was assessed on serial dilutions of high-titre plasmas containing different genotypes for HBV (A–E, n = 9) and HCV (1a, 1b, 2–5, n = 12). Results: Overall test failure, mostly internal control amplification failure, was 2.3% and was not influenced by matrix types (fresh or frozen). For HBV VL, κ agreement was 74%, with 27 (12.6%) discrepancies. Correlation between HBV assays on 72 quantified samples by both methods was excellent ( r = 0.963) with a mean bias (NeuMoDx™–Veris) of 0.21 log IU/mL. For HCV VL, κ agreement reached 94%, with 9 (2.8%) discrepancies. The r correlation factor between assays on 104 samples was 0.960 with a mean bias of –0.14 log IU/mL (NeuMoDx™–Veris). Serial dilutions confirmed the claimed linear ranges for all analysed HBV and HCV genotypes. The mean turnaround time was 72 minutes (range 55–101 minutes)Abstract: Objective: Monitoring of viral loads (VL) for hepatitis B and C viruses (HBV; HCV) is essential to evaluate disease progression and treatment response. Automated, random-access rapid systems are becoming standard to provide clinicians with reliable VL. The aim of this study was to evaluate the analytical performances of the recently launched NeuMoDx™ for HBV-DNA and HCV-RNA quantification. Methods: Clinical samples routinely quantified on the Beckman–Veris system were either retrospectively (frozen samples; HBV n = 178, HCV n = 249), or in parallel (fresh primary tubes; HBV n = 103, HCV n = 117) tested using NeuMoDx™. Linearity range was assessed on serial dilutions of high-titre plasmas containing different genotypes for HBV (A–E, n = 9) and HCV (1a, 1b, 2–5, n = 12). Results: Overall test failure, mostly internal control amplification failure, was 2.3% and was not influenced by matrix types (fresh or frozen). For HBV VL, κ agreement was 74%, with 27 (12.6%) discrepancies. Correlation between HBV assays on 72 quantified samples by both methods was excellent ( r = 0.963) with a mean bias (NeuMoDx™–Veris) of 0.21 log IU/mL. For HCV VL, κ agreement reached 94%, with 9 (2.8%) discrepancies. The r correlation factor between assays on 104 samples was 0.960 with a mean bias of –0.14 log IU/mL (NeuMoDx™–Veris). Serial dilutions confirmed the claimed linear ranges for all analysed HBV and HCV genotypes. The mean turnaround time was 72 minutes (range 55–101 minutes) for HBV and 96 minutes (range 78–133 minutes) for HCV. Conclusion: Results obtained on the NeuMoDx™ confirmed the overall good functionality of the system with a short turn-around-time, full traceability and easy handling. These results on HBV and HCV VL look promising and should be challenged with further comparisons. … (more)
- Is Part Of:
- Clinical microbiology and infection. Volume 27:Number 11(2021)
- Journal:
- Clinical microbiology and infection
- Issue:
- Volume 27:Number 11(2021)
- Issue Display:
- Volume 27, Issue 11 (2021)
- Year:
- 2021
- Volume:
- 27
- Issue:
- 11
- Issue Sort Value:
- 2021-0027-0011-0000
- Page Start:
- 1693.e9
- Page End:
- 1693.e15
- Publication Date:
- 2021-11
- Subjects:
- Correlation analysis -- Hepatitis -- Molecular biology -- Viral load
Medical microbiology -- Periodicals
Diagnostic microbiology -- Periodicals
Communicable diseases -- Periodicals
Infection -- Periodicals
616.01 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1469-0691 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1016/j.cmi.2021.02.023 ↗
- Languages:
- English
- ISSNs:
- 1198-743X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.305520
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19776.xml