Automated Left Ventricular Dimension Assessment Using Artificial Intelligence Developed and Validated by a UK-Wide Collaborative. (17th May 2021)
- Record Type:
- Journal Article
- Title:
- Automated Left Ventricular Dimension Assessment Using Artificial Intelligence Developed and Validated by a UK-Wide Collaborative. (17th May 2021)
- Main Title:
- Automated Left Ventricular Dimension Assessment Using Artificial Intelligence Developed and Validated by a UK-Wide Collaborative
- Authors:
- Howard, James P.
Stowell, Catherine C.
Cole, Graham D.
Ananthan, Kajaluxy
Demetrescu, Camelia D.
Pearce, Keith
Rajani, Ronak
Sehmi, Jobanpreet
Vimalesvaran, Kavitha
Kanaganayagam, G. Sunthar
McPhail, Eleanor
Ghosh, Arjun K.
Chambers, John B.
Singh, Amar P.
Zolgharni, Massoud
Rana, Bushra
Francis, Darrel P.
Shun-Shin, Matthew J. - Abstract:
- Abstract : Supplemental Digital Content is available in the text. Abstract : Background: requires training and validation to standards expected of humans. We developed an online platform and established the Unity Collaborative to build a dataset of expertise from 17 hospitals for training, validation, and standardization of such techniques. Methods: The training dataset consisted of 2056 individual frames drawn at random from 1265 parasternal long-axis video-loops of patients undergoing clinical echocardiography in 2015 to 2016. Nine experts labeled these images using our online platform. From this, we trained a convolutional neural network to identify keypoints. Subsequently, 13 experts labeled a validation dataset of the end-systolic and end-diastolic frame from 100 new video-loops, twice each. The 26-opinion consensus was used as the reference standard. The primary outcome was precision SD, the SD of the differences between AI measurement and expert consensus. Results: In the validation dataset, the AI's precision SD for left ventricular internal dimension was 3.5 mm. For context, precision SD of individual expert measurements against the expert consensus was 4.4 mm. Intraclass correlation coefficient between AI and expert consensus was 0.926 (95% CI, 0.904–0.944), compared with 0.817 (0.778–0.954) between individual experts and expert consensus. For interventricular septum thickness, precision SD was 1.8 mm for AI (intraclass correlation coefficient, 0.809; 0.729–0.967),Abstract : Supplemental Digital Content is available in the text. Abstract : Background: requires training and validation to standards expected of humans. We developed an online platform and established the Unity Collaborative to build a dataset of expertise from 17 hospitals for training, validation, and standardization of such techniques. Methods: The training dataset consisted of 2056 individual frames drawn at random from 1265 parasternal long-axis video-loops of patients undergoing clinical echocardiography in 2015 to 2016. Nine experts labeled these images using our online platform. From this, we trained a convolutional neural network to identify keypoints. Subsequently, 13 experts labeled a validation dataset of the end-systolic and end-diastolic frame from 100 new video-loops, twice each. The 26-opinion consensus was used as the reference standard. The primary outcome was precision SD, the SD of the differences between AI measurement and expert consensus. Results: In the validation dataset, the AI's precision SD for left ventricular internal dimension was 3.5 mm. For context, precision SD of individual expert measurements against the expert consensus was 4.4 mm. Intraclass correlation coefficient between AI and expert consensus was 0.926 (95% CI, 0.904–0.944), compared with 0.817 (0.778–0.954) between individual experts and expert consensus. For interventricular septum thickness, precision SD was 1.8 mm for AI (intraclass correlation coefficient, 0.809; 0.729–0.967), versus 2.0 mm for individuals (intraclass correlation coefficient, 0.641; 0.568–0.716). For posterior wall thickness, precision SD was 1.4 mm for AI (intraclass correlation coefficient, 0.535 [95% CI, 0.379–0.661]), versus 2.2 mm for individuals (0.366 [0.288–0.462]). We present all images and annotations. This highlights challenging cases, including poor image quality and tapered ventricles. Conclusions: Experts at multiple institutions successfully cooperated to build a collaborative AI. This performed as well as individual experts. Future echocardiographic AI research should use a consensus of experts as a reference. Our collaborative welcomes new partners who share our commitment to publish all methods, code, annotations, and results openly. … (more)
- Is Part Of:
- Circulation. Volume 14:Number 5(2021)
- Journal:
- Circulation
- Issue:
- Volume 14:Number 5(2021)
- Issue Display:
- Volume 14, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 14
- Issue:
- 5
- Issue Sort Value:
- 2021-0014-0005-0000
- Page Start:
- e011951
- Page End:
- Publication Date:
- 2021-05-17
- Subjects:
- consensus -- echocardiography -- hospital -- left ventricle -- machine learning
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.1075405 - Journal URLs:
- http://circimaging.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCIMAGING.120.011951 ↗
- Languages:
- English
- ISSNs:
- 1941-9651
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262750
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19762.xml