Printing a static progressive orthosis for hand rehabilitation. Issue 8 (17th June 2021)
- Record Type:
- Journal Article
- Title:
- Printing a static progressive orthosis for hand rehabilitation. Issue 8 (17th June 2021)
- Main Title:
- Printing a static progressive orthosis for hand rehabilitation
- Authors:
- Huang, Li-Ying
Wang, Tien-Hsiang
Chang, Bao-Chi
Huang, Chia-I
Chou, Li-Wei
Wang, Shyh-Jen
Chen, Wei-Ming - Abstract:
- Abstract : Background: Static progressive orthosis is used for the treatment of severe joint contracture after trauma and/or surgery. However, a custom-fabricated static progressive splint would be expensive and labor intensive. Especially, owing to very limited payment under the current Taiwanese National Health Insurance, the incentives to fabricate a patient-specific splint are insufficient for a therapist. To ease splint construction, we introduced three-dimensional (3D)-printed "shark fin"-shaped device works as a static progressive orthosis for the hand rehabilitation. The aim of this study was to describe and demonstrate the newly designed device. Methods: This study included a 46-year male suffered from a left distal radius fracture and underwent open reduction internal fixation and a 23-year male with the right thumb flexor pollicis longus rupture, requiring tendon repair. Both subjects used this "shark fin"-shaped device to stretch for increasing range of motion (ROM) of wrist extension and the thumb. Results: The patient receiving ulnar shortening surgery used this device to stretch for increasing ROM of wrist extension. The active ROM of wrist extension improved from 30° to 50°. The other patient with the right thumb flexor pollicis longus rupture suffered from thumb contracture; the ROMs of the metacarpophalangeal (MCP) joint and interphalangeal (IP) joint were 40°–55° and 20°–25°, respectively. After tenolysis surgery, his ROMs of the MCP and IP joints wereAbstract : Background: Static progressive orthosis is used for the treatment of severe joint contracture after trauma and/or surgery. However, a custom-fabricated static progressive splint would be expensive and labor intensive. Especially, owing to very limited payment under the current Taiwanese National Health Insurance, the incentives to fabricate a patient-specific splint are insufficient for a therapist. To ease splint construction, we introduced three-dimensional (3D)-printed "shark fin"-shaped device works as a static progressive orthosis for the hand rehabilitation. The aim of this study was to describe and demonstrate the newly designed device. Methods: This study included a 46-year male suffered from a left distal radius fracture and underwent open reduction internal fixation and a 23-year male with the right thumb flexor pollicis longus rupture, requiring tendon repair. Both subjects used this "shark fin"-shaped device to stretch for increasing range of motion (ROM) of wrist extension and the thumb. Results: The patient receiving ulnar shortening surgery used this device to stretch for increasing ROM of wrist extension. The active ROM of wrist extension improved from 30° to 50°. The other patient with the right thumb flexor pollicis longus rupture suffered from thumb contracture; the ROMs of the metacarpophalangeal (MCP) joint and interphalangeal (IP) joint were 40°–55° and 20°–25°, respectively. After tenolysis surgery, his ROMs of the MCP and IP joints were improved to 10°–35° and 40°–65°, respectively. Following physical therapy by applying the device, his ROMs of the MCP and IP joints were further increased to 0°–40° and 25°–70°, respectively. Conclusion: Incorporating the "shark fin"-shaped orthosis into hand rehabilitation increased the ROM of wrist extension for a patient with distal radius fracture and improved the ROM of the MCP and IP joints in another patient after tenolysis surgery. … (more)
- Is Part Of:
- Journal of the Chinese Medical Association. Volume 84:Issue 8(2021)
- Journal:
- Journal of the Chinese Medical Association
- Issue:
- Volume 84:Issue 8(2021)
- Issue Display:
- Volume 84, Issue 8 (2021)
- Year:
- 2021
- Volume:
- 84
- Issue:
- 8
- Issue Sort Value:
- 2021-0084-0008-0000
- Page Start:
- 795
- Page End:
- 798
- Publication Date:
- 2021-06-17
- Subjects:
- 3D printing -- Hand rehabilitation -- Interphalangeal joint -- Joint contracture -- Metacarpophalangeal joint -- Radius fracture -- Static progressive orthosis -- Tenolysis
Medicine -- Periodicals
610.5 - Journal URLs:
- https://journals.lww.com/jcma/pages/default.aspx ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1097/JCMA.0000000000000568 ↗
- Languages:
- English
- ISSNs:
- 1726-4901
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4729.330050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19774.xml