Treatment of Fecal Incontinence With a Rechargeable Sacral Neuromodulation System: Efficacy, Clinical Outcome, and Ease of Use—Six‐Month Follow‐Up. Issue 7 (27th October 2020)
- Record Type:
- Journal Article
- Title:
- Treatment of Fecal Incontinence With a Rechargeable Sacral Neuromodulation System: Efficacy, Clinical Outcome, and Ease of Use—Six‐Month Follow‐Up. Issue 7 (27th October 2020)
- Main Title:
- Treatment of Fecal Incontinence With a Rechargeable Sacral Neuromodulation System: Efficacy, Clinical Outcome, and Ease of Use—Six‐Month Follow‐Up
- Authors:
- Jottard, Katleen
Van den Broeck, Sylvie
Komen, Niels
Bruyninx, Luc
De Wachter, Stefan - Abstract:
- Abstract: Objective: Sacral neuromodulation is an effective treatment for fecal incontinence (FI) after conservative treatments have failed. A new rechargeable sacral neuromodulation system (r‐SNM) includes a rechargeable implantable neurostimulator (INS). No data is available of the use of this technology in patients with fecal incontinence. Materials and Methods: Fifteen patients with FI were implanted with the Axonics rechargeable SNM system in a single‐stage implant procedure and prospectively followed. Primary outcome was fecal incontinence episodes at four weeks and six months measured with stools diary. Success was defined as at least 50% improvement of fecal incontinence episodes. Additionally, quality of life and ease of use were evaluated. Results: At four weeks, 13 participants (87%) were test responders based on ≥50% reduction in FI episodes as documented on their bowel diary. Weekly FI episodes decreased from a median (25%–75% range) of 8 (5.8–20.3) at baseline to a median of 1.5 (0.4–4.5) at four weeks ( p = 0.001), and 1.5 (0–2.6) at six months ( p = 0.001), corresponding to 75% and 79% reduction in weekly FI episodes. Of the 13 subjects having ≥50% reduction in FI episodes at four weeks, 12 (PP = 92%) were therapy responders at six months. There were no unanticipated device or procedure‐related adverse events. Mean time to recharge the system was 37 ± 3 min once or twice per week. All patients were moderately or very satisfied with the system and itsAbstract: Objective: Sacral neuromodulation is an effective treatment for fecal incontinence (FI) after conservative treatments have failed. A new rechargeable sacral neuromodulation system (r‐SNM) includes a rechargeable implantable neurostimulator (INS). No data is available of the use of this technology in patients with fecal incontinence. Materials and Methods: Fifteen patients with FI were implanted with the Axonics rechargeable SNM system in a single‐stage implant procedure and prospectively followed. Primary outcome was fecal incontinence episodes at four weeks and six months measured with stools diary. Success was defined as at least 50% improvement of fecal incontinence episodes. Additionally, quality of life and ease of use were evaluated. Results: At four weeks, 13 participants (87%) were test responders based on ≥50% reduction in FI episodes as documented on their bowel diary. Weekly FI episodes decreased from a median (25%–75% range) of 8 (5.8–20.3) at baseline to a median of 1.5 (0.4–4.5) at four weeks ( p = 0.001), and 1.5 (0–2.6) at six months ( p = 0.001), corresponding to 75% and 79% reduction in weekly FI episodes. Of the 13 subjects having ≥50% reduction in FI episodes at four weeks, 12 (PP = 92%) were therapy responders at six months. There were no unanticipated device or procedure‐related adverse events. Mean time to recharge the system was 37 ± 3 min once or twice per week. All patients were moderately or very satisfied with the system and its effect. Conclusions: The r‐SNM system provides safe and effective therapy in patients with FI at six months. … (more)
- Is Part Of:
- Neuromodulaton. Volume 24:Issue 7(2021)
- Journal:
- Neuromodulaton
- Issue:
- Volume 24:Issue 7(2021)
- Issue Display:
- Volume 24, Issue 7 (2021)
- Year:
- 2021
- Volume:
- 24
- Issue:
- 7
- Issue Sort Value:
- 2021-0024-0007-0000
- Page Start:
- 1284
- Page End:
- 1288
- Publication Date:
- 2020-10-27
- Subjects:
- Neuromodulation -- fecal incontinence -- rechargeable -- sacral
Central nervous system -- Physiology -- Periodicals
Central nervous system -- Diseases -- Periodicals
616.8 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1525-1403 ↗
https://www.sciencedirect.com/journal/neuromodulation-technology-at-the-neural-interface ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ner.13298 ↗
- Languages:
- English
- ISSNs:
- 1094-7159
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.504100
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: