Endovascular treatment of intracranial aneurysms with the LVIS device: a systematic review. (20th May 2016)
- Record Type:
- Journal Article
- Title:
- Endovascular treatment of intracranial aneurysms with the LVIS device: a systematic review. (20th May 2016)
- Main Title:
- Endovascular treatment of intracranial aneurysms with the LVIS device: a systematic review
- Authors:
- Zhang, Xiaoguang
Zhong, Junjie
Gao, Heng
Xu, Feng
Bambakidis, Nicholas C - Abstract:
- Abstract : Objective: Despite promising initial results, current knowledge regarding the use of the Low-profile Visualized Intraluminal Support (LVIS) device to treat wide-necked intracranial aneurysms is still limited. Our aim is to evaluate the feasibility, efficacy, and safety of the LVIS device in stent-assisted coiling of intracranial aneurysms. Methods: We conducted a systematic review by searching PubMed, EMBASE, and Cochrane Library for all published studies on the treatment of intracranial aneurysms with the LVIS device up to March 2016. Feasibility was evaluated by the technical success rate during the procedure, efficacy was evaluated by the rate of complete aneurysm occlusion at follow-up angiography, and safety was assessed by procedure-related morbidity and mortality. Results: A total of nine studies were included in the analysis, including 384 patients with 390 aneurysms. The overall technical success rate was 96.8% (95% CI 94.4% to 99.1%). The aneurysmal complete occlusion rate was 54.6% (95% CI 31.8% to 77.4%) on immediate control and 84.3% (95% CI 78.9% to 89.7%) at follow-up angiography. Procedural-related morbidity and mortality were 1.4% (95% CI 0.2% to 2.6%) and 0% (95% CI 0%), respectively. The thromboembolic event rate was 4.9% (95% CI 1.9% to 7.9%) and the hemorrhagic event rate was 2.1% (95% CI 0.7% to 3.5%), with 0.9% (95% CI 0% to 1.8%) experiencing neurologic hemorrhagic complications and 1.9% (95% CI 0.5% to 3.2%) experiencing non-neurologicAbstract : Objective: Despite promising initial results, current knowledge regarding the use of the Low-profile Visualized Intraluminal Support (LVIS) device to treat wide-necked intracranial aneurysms is still limited. Our aim is to evaluate the feasibility, efficacy, and safety of the LVIS device in stent-assisted coiling of intracranial aneurysms. Methods: We conducted a systematic review by searching PubMed, EMBASE, and Cochrane Library for all published studies on the treatment of intracranial aneurysms with the LVIS device up to March 2016. Feasibility was evaluated by the technical success rate during the procedure, efficacy was evaluated by the rate of complete aneurysm occlusion at follow-up angiography, and safety was assessed by procedure-related morbidity and mortality. Results: A total of nine studies were included in the analysis, including 384 patients with 390 aneurysms. The overall technical success rate was 96.8% (95% CI 94.4% to 99.1%). The aneurysmal complete occlusion rate was 54.6% (95% CI 31.8% to 77.4%) on immediate control and 84.3% (95% CI 78.9% to 89.7%) at follow-up angiography. Procedural-related morbidity and mortality were 1.4% (95% CI 0.2% to 2.6%) and 0% (95% CI 0%), respectively. The thromboembolic event rate was 4.9% (95% CI 1.9% to 7.9%) and the hemorrhagic event rate was 2.1% (95% CI 0.7% to 3.5%), with 0.9% (95% CI 0% to 1.8%) experiencing neurologic hemorrhagic complications and 1.9% (95% CI 0.5% to 3.2%) experiencing non-neurologic hemorrhagic complications. Conclusions: Our systematic review suggests that endovascular treatment of intracranial aneurysms with the LVIS device is feasible, safe, and effective in the short term. However, the rate of thromboembolic complications is not negligible. Further prospective studies are needed to evaluate the long-term efficacy and safety of the LVIS device. … (more)
- Is Part Of:
- Journal of neurointerventional surgery. Volume 9:Number 6(2017)
- Journal:
- Journal of neurointerventional surgery
- Issue:
- Volume 9:Number 6(2017)
- Issue Display:
- Volume 9, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 9
- Issue:
- 6
- Issue Sort Value:
- 2017-0009-0006-0000
- Page Start:
- 553
- Page End:
- 557
- Publication Date:
- 2016-05-20
- Subjects:
- Aneurysm -- Coil -- Stent
Nervous system -- Surgery -- Periodicals
Cerebrovascular disease -- Surgery -- Periodicals
617.48 - Journal URLs:
- http://www.bmj.com/archive ↗
http://jnis.bmj.com/ ↗ - DOI:
- 10.1136/neurintsurg-2016-012403 ↗
- Languages:
- English
- ISSNs:
- 1759-8478
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19753.xml