E-059 Calculation of mean arterial blood flow rate from digital subtraction angiography: effect of injection conditions. (22nd July 2018)
- Record Type:
- Journal Article
- Title:
- E-059 Calculation of mean arterial blood flow rate from digital subtraction angiography: effect of injection conditions. (22nd July 2018)
- Main Title:
- E-059 Calculation of mean arterial blood flow rate from digital subtraction angiography: effect of injection conditions
- Authors:
- Gross, M
Kovarovic, B
Woo, H
Fiorella, D
Sadasivan, C - Abstract:
- Abstract : Introduction: Several methods of extracting arterial blood flow rates from angiography have been attempted over the past decades. 1 However, such methods are not used clinically, primarily because catheter-based contrast injections in arteries can result in substantial pressure and flow disturbances during the injection. 2 We hypothesize that injections which cause minimal hemodynamic disturbance in the vessel of interest would result in greater accuracy of angiographically calculated mean flow rates. We conducted an in vitro study under various injection conditions to evaluate this hypothesis. Methods: Angiography at 15 FPS was acquired in a Circle of Willis silicone replica assembled on a pulsatile flow simulator (figure 1, Vascular Simulations, Stony Brook, NY). Injection conditions included (total n=72): catheter-tip position (right carotid, ascending aorta), catheter type (6F end-hole, 6F side-holes), baseline internal carotid flow (4.3, 5.3, 8.3 cc/s), injection rate (carotid: 2, 6 cc/s; aorta: 10, 20 cc/s). Contrast concentration-time curves were recorded at proximal and distal locations on the right internal carotid artery (figure 1) and the bolus transit-time between these two locations was calculated using three different methods (Mean Transit Time, Time to Peak, Cross Correlation). Then, arterial mean flow rate (ml/s)=arterial segment volume(ml)/transit-time(s). Actual flow in the vessel was measured with a flow meter. Results: Statistically significantAbstract : Introduction: Several methods of extracting arterial blood flow rates from angiography have been attempted over the past decades. 1 However, such methods are not used clinically, primarily because catheter-based contrast injections in arteries can result in substantial pressure and flow disturbances during the injection. 2 We hypothesize that injections which cause minimal hemodynamic disturbance in the vessel of interest would result in greater accuracy of angiographically calculated mean flow rates. We conducted an in vitro study under various injection conditions to evaluate this hypothesis. Methods: Angiography at 15 FPS was acquired in a Circle of Willis silicone replica assembled on a pulsatile flow simulator (figure 1, Vascular Simulations, Stony Brook, NY). Injection conditions included (total n=72): catheter-tip position (right carotid, ascending aorta), catheter type (6F end-hole, 6F side-holes), baseline internal carotid flow (4.3, 5.3, 8.3 cc/s), injection rate (carotid: 2, 6 cc/s; aorta: 10, 20 cc/s). Contrast concentration-time curves were recorded at proximal and distal locations on the right internal carotid artery (figure 1) and the bolus transit-time between these two locations was calculated using three different methods (Mean Transit Time, Time to Peak, Cross Correlation). Then, arterial mean flow rate (ml/s)=arterial segment volume(ml)/transit-time(s). Actual flow in the vessel was measured with a flow meter. Results: Statistically significant linear correlations were observed between measured and angiographically calculated flow rates under nearly all injection conditions. Cross correlation was substantially superior to the other two methods (p<0.0001). The error between measured and calculated flows was significantly (p=0.001) lower with the side-hole catheter (11%±11%) as compared to the end-hole catheter (22%±15%). Similarly, the aortic injections showed lower error (13%±11%) than the carotid injections (20%±17%), but without statistical significance (p=0.64). Conclusions: Calculation of mean arterial flow rates by angiography is feasible. The accuracy is higher when the injection causes the least hemodynamic disturbance (side-hole catheter, aortic injection). Improvements to the technique need to be made in order to achieve reliable accuracy in patients, especially under standard (˜4 FPS) frame rate acquisitions. References: Lieber BB, et al. Crit Rev Biomed Eng. 2005;33(1):1–1022. Kovarovic B, et al. Cardiovasc Eng Technol. 2018. doi:10.1007/s13239-018-0344-3 Disclosures: M. Gross: None. B. Kovarovic: None. H. Woo: 4; C; Vascular Simulations. 6; C; Cerenovus, JnJ. D. Fiorella: 2; C; Penumbra, Microvention, Medtronic. 4; C; Vascular Simulations. 6; C; Cerenovus JnJ. C. Sadasivan: 4; C; Vascular Simulations. … (more)
- Is Part Of:
- Journal of neurointerventional surgery. Volume 10(2018)Supplement 2
- Journal:
- Journal of neurointerventional surgery
- Issue:
- Volume 10(2018)Supplement 2
- Issue Display:
- Volume 10, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 10
- Issue:
- 2
- Issue Sort Value:
- 2018-0010-0002-0000
- Page Start:
- A77
- Page End:
- A78
- Publication Date:
- 2018-07-22
- Subjects:
- Nervous system -- Surgery -- Periodicals
Cerebrovascular disease -- Surgery -- Periodicals
617.48 - Journal URLs:
- http://www.bmj.com/archive ↗
http://jnis.bmj.com/ ↗ - DOI:
- 10.1136/neurintsurg-2018-SNIS.135 ↗
- Languages:
- English
- ISSNs:
- 1759-8478
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19716.xml