A 10 J shock impedance in sinus rhythm correlates with a 65 J defibrillation impedance during subcutaneous defibrillator implantation using an intermuscular technique. (28th September 2021)
- Record Type:
- Journal Article
- Title:
- A 10 J shock impedance in sinus rhythm correlates with a 65 J defibrillation impedance during subcutaneous defibrillator implantation using an intermuscular technique. (28th September 2021)
- Main Title:
- A 10 J shock impedance in sinus rhythm correlates with a 65 J defibrillation impedance during subcutaneous defibrillator implantation using an intermuscular technique
- Authors:
- Okabe, Toshimasa
Savona, Salvatore J.
Matto, Faisal
Ward, Chad
Singh, Prabhpreet
Afzal, Muhammad R.
Kalbfleisch, Steven J.
Weiss, Raul
Houmsse, Mahmoud
Augostini, Ralph S.
Hummel, John D.
Daoud, Emile G. - Abstract:
- Abstract: Introduction: Defibrillation testing (DT) is recommended during the subcutaneous defibrillator (S‐ICD) placement. We sought to compare 10 J shock impedance in sinus rhythm (SR) with 65 J defibrillation impedance and evaluate device position on a postimplant chest X‐ray (CXR) using an intermuscular (IM) technique. Methods: Consecutive S‐ICD implantations between 12/2019 and 12/2020 at The Ohio State University were reviewed. All implantations were performed using a two‐incision IM technique. Standard DT with 65 J shock and 10 J shock in SR were performed unless contraindicated. The PRAETORIAN score was calculated based on CXR. Results: A total of 37 patients (age: 47.2 ± 15.8 years old, male: n = 26 [70.3%], body mass index: 30.1 ± 6.7 kg/m 2 ) underwent IM S‐ICD implantation, and of those, 27 (73%) underwent both 65 J shock and 10 J shock in SR. The coefficient of determination ( R 2 ) between 10 J shock impedance and 65 J shock impedance was 0.84. The mean of an impedance difference was 1.6 ± 4.8 Ω (minimum – 11 and maximum 8). Postimplant CXR was available for 33 out of 37 patients (89.2%). The PRAETORIAN score was less than 90 in all patients and the mean score was 32.7 ± 8.8. Conclusion: We demonstrated that 10 J shock impedance in SR correlated well with 65 J defibrillation impedance during IM S‐ICD implantation. An IM implantation technique provides excellent generator location on postimplant CXR. The IM technique combined with 10 J shock in SR may beAbstract: Introduction: Defibrillation testing (DT) is recommended during the subcutaneous defibrillator (S‐ICD) placement. We sought to compare 10 J shock impedance in sinus rhythm (SR) with 65 J defibrillation impedance and evaluate device position on a postimplant chest X‐ray (CXR) using an intermuscular (IM) technique. Methods: Consecutive S‐ICD implantations between 12/2019 and 12/2020 at The Ohio State University were reviewed. All implantations were performed using a two‐incision IM technique. Standard DT with 65 J shock and 10 J shock in SR were performed unless contraindicated. The PRAETORIAN score was calculated based on CXR. Results: A total of 37 patients (age: 47.2 ± 15.8 years old, male: n = 26 [70.3%], body mass index: 30.1 ± 6.7 kg/m 2 ) underwent IM S‐ICD implantation, and of those, 27 (73%) underwent both 65 J shock and 10 J shock in SR. The coefficient of determination ( R 2 ) between 10 J shock impedance and 65 J shock impedance was 0.84. The mean of an impedance difference was 1.6 ± 4.8 Ω (minimum – 11 and maximum 8). Postimplant CXR was available for 33 out of 37 patients (89.2%). The PRAETORIAN score was less than 90 in all patients and the mean score was 32.7 ± 8.8. Conclusion: We demonstrated that 10 J shock impedance in SR correlated well with 65 J defibrillation impedance during IM S‐ICD implantation. An IM implantation technique provides excellent generator location on postimplant CXR. The IM technique combined with 10 J shock in SR may be sufficient to predict and ensure the defibrillation efficacy of the S‐ICD. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 32:Number 11(2021)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 32:Number 11(2021)
- Issue Display:
- Volume 32, Issue 11 (2021)
- Year:
- 2021
- Volume:
- 32
- Issue:
- 11
- Issue Sort Value:
- 2021-0032-0011-0000
- Page Start:
- 3027
- Page End:
- 3034
- Publication Date:
- 2021-09-28
- Subjects:
- anesthesia -- defibrillation testing -- impedance -- intermuscular -- subcutaneous defibrillator
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.15249 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19723.xml