Dynamic effect of three locking plates fixated to humeral fracture based on multibody musculoskeletal model. Issue 6 (2nd September 2021)
- Record Type:
- Journal Article
- Title:
- Dynamic effect of three locking plates fixated to humeral fracture based on multibody musculoskeletal model. Issue 6 (2nd September 2021)
- Main Title:
- Dynamic effect of three locking plates fixated to humeral fracture based on multibody musculoskeletal model
- Authors:
- Jian‐Qiao Peng, Matthew
Chen, Chin‐Tu
MA, LiMin
JU, Xiangyang
Khambay, Balvinder - Abstract:
- Abstract: Objective: This study attempts to analyse the biomechanical effect of internal fixation (plated in parallel or plated vertically) on the basis of distal humeral fractures on musculoskeletal multibody dynamics using AnyBody in Finite Element Method. Method: Humeral 3D models were reconstructed by MIMICS after volunteers' CT image input in *.dicom format, and processed by Geomagic Studio for surfaces, while locking plates and screws were then designed by Pro‐E. A humeral model of T‐type fracture was created and assembled in Hypermesh, to integrate fixtures (e.g., MPL/PML/ML), to grid the mesh and then assign materials. A musculoskeletal model of the upper limb was established by AnyBody to simulate elbow flexion and extension. They were finally imported to Abaqus for boundary conditions and dynamic analysis. Result: In terms of Von Mises stress, its maximum increased and then decreased gradually during the joint motion, but p > 0.05 in SPSS suggests no significant difference for all three fixtures. In terms of displacement, when the elbow was at 90°, each motional pattern reached its peak as follows: ML180° = 0.28 mm, MPL90° = 0.49 mm & PML90° = 0.54 mm during flexion; ML180° = 0.073 mm, MPL90° = 0.10 mm & PML90° = 0.12 mm during extension. p < 0.05 suggests a significant difference for the displacements of all three fixations. p = 0.007 < 0.01667 suggests the significant difference between the two fixations, for example, PML90° and ML180°, indicating that theAbstract: Objective: This study attempts to analyse the biomechanical effect of internal fixation (plated in parallel or plated vertically) on the basis of distal humeral fractures on musculoskeletal multibody dynamics using AnyBody in Finite Element Method. Method: Humeral 3D models were reconstructed by MIMICS after volunteers' CT image input in *.dicom format, and processed by Geomagic Studio for surfaces, while locking plates and screws were then designed by Pro‐E. A humeral model of T‐type fracture was created and assembled in Hypermesh, to integrate fixtures (e.g., MPL/PML/ML), to grid the mesh and then assign materials. A musculoskeletal model of the upper limb was established by AnyBody to simulate elbow flexion and extension. They were finally imported to Abaqus for boundary conditions and dynamic analysis. Result: In terms of Von Mises stress, its maximum increased and then decreased gradually during the joint motion, but p > 0.05 in SPSS suggests no significant difference for all three fixtures. In terms of displacement, when the elbow was at 90°, each motional pattern reached its peak as follows: ML180° = 0.28 mm, MPL90° = 0.49 mm & PML90° = 0.54 mm during flexion; ML180° = 0.073 mm, MPL90° = 0.10 mm & PML90° = 0.12 mm during extension. p < 0.05 suggests a significant difference for the displacements of all three fixations. p = 0.007 < 0.01667 suggests the significant difference between the two fixations, for example, PML90° and ML180°, indicating that the peak displacement of ML180° is less than that of PML90°. Conclusion: After generally analysed in musculoskeletal dynamics, the biomechanical property of the fixtures was presented as follows: the displacement of the parallel plate was less than that of the vertical, and the parallel plate may optimise the clinical reduction anatomically. … (more)
- Is Part Of:
- International journal of medical robotics and computer assisted surgery. Volume 17:Issue 6(2021)
- Journal:
- International journal of medical robotics and computer assisted surgery
- Issue:
- Volume 17:Issue 6(2021)
- Issue Display:
- Volume 17, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 17
- Issue:
- 6
- Issue Sort Value:
- 2021-0017-0006-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2021-09-02
- Subjects:
- AnyBody -- double plates -- multibody -- musculoskeletal -- T‐fracture
Robotics in medicine -- Periodicals
Surgery -- Technological innovations -- Periodicals
Imaging systems in medicine -- Periodicals
617.90285 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1478-596X ↗
http://www.roboticpublications.com ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/rcs.2323 ↗
- Languages:
- English
- ISSNs:
- 1478-5951
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.347800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19683.xml