Simulation of the mechanical behavior of osteons using artificial gravity devices in microgravity. Issue 14 (10th November 2021)
- Record Type:
- Journal Article
- Title:
- Simulation of the mechanical behavior of osteons using artificial gravity devices in microgravity. Issue 14 (10th November 2021)
- Main Title:
- Simulation of the mechanical behavior of osteons using artificial gravity devices in microgravity
- Authors:
- Zhang, Hao
Liu, Hai-Ying
Zhang, Chun-Qiu
Liu, Zhen-Zhong
Wang, Wei - Abstract:
- Abstract: Aviation medical research shows that disuse osteoporosis will occur after long-term space flight. Even with countermeasures such as exercise and drug treatments, this outcome cannot be avoided in flight. In recent years, the application of artificial gravity devices that change the mechanical microenvironment of bone in microgravity have shown promise in mitigating the risk of disuse osteoporosis. Considering the existence of osteocytes, a fluid-solid coupling finite element model for osteons with two-stage pore structure (Haversian canal, lacunar-canalicular system) was established. In order to study the changes in the mechanical behavior of osteocytes under the action of various artificial gravity (AG) devices, including long-arm centrifuge (LAC), short-arm centrifuge (SAC), and a lower body negative pressure (LBNP) chamber. In addition, the difference in pulsating pressure and static pressure stress caused by the gravity gradient under the AG devices was examined. The simulation results showed that the AG devices could effectively improve the stress level of osteocytes in microgravity. The mechanical microenvironment of osteocytes that was provided by the LAC was closest to that of the Earth' s gravitational field. The mechanical stimulation on osteocytes was not significantly improved by the SAC, but from a practical viewpoint, it occupied less space than the LAC. The LBNP chamber created a higher level of stress for osteocytes. Therefore, the LAC was an idealAbstract: Aviation medical research shows that disuse osteoporosis will occur after long-term space flight. Even with countermeasures such as exercise and drug treatments, this outcome cannot be avoided in flight. In recent years, the application of artificial gravity devices that change the mechanical microenvironment of bone in microgravity have shown promise in mitigating the risk of disuse osteoporosis. Considering the existence of osteocytes, a fluid-solid coupling finite element model for osteons with two-stage pore structure (Haversian canal, lacunar-canalicular system) was established. In order to study the changes in the mechanical behavior of osteocytes under the action of various artificial gravity (AG) devices, including long-arm centrifuge (LAC), short-arm centrifuge (SAC), and a lower body negative pressure (LBNP) chamber. In addition, the difference in pulsating pressure and static pressure stress caused by the gravity gradient under the AG devices was examined. The simulation results showed that the AG devices could effectively improve the stress level of osteocytes in microgravity. The mechanical microenvironment of osteocytes that was provided by the LAC was closest to that of the Earth' s gravitational field. The mechanical stimulation on osteocytes was not significantly improved by the SAC, but from a practical viewpoint, it occupied less space than the LAC. The LBNP chamber created a higher level of stress for osteocytes. Therefore, the LAC was an ideal device for replacing Earth' s gravitational field, except for the practical limitations of its physical size. In contrast, the LBNP device had the greatest application potential in training for its expansibility and convenience. … (more)
- Is Part Of:
- Computer methods in biomechanics and biomedical engineering. Volume 24:Issue 14(2021)
- Journal:
- Computer methods in biomechanics and biomedical engineering
- Issue:
- Volume 24:Issue 14(2021)
- Issue Display:
- Volume 24, Issue 14 (2021)
- Year:
- 2021
- Volume:
- 24
- Issue:
- 14
- Issue Sort Value:
- 2021-0024-0014-0000
- Page Start:
- 1578
- Page End:
- 1587
- Publication Date:
- 2021-11-10
- Subjects:
- Microgravity -- artificial gravity -- osteocyte -- lacunar-canalicular system -- numerical simulation
Biomechanics -- Data processing -- Periodicals
Biomedical engineering -- Periodicals
Biomechanics -- Periodicals
Biomedical Engineering -- methods -- Periodicals
Computing Methodologies -- Periodicals
612.7 - Journal URLs:
- http://www.tandfonline.com/toc/gcmb20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/10255842.2021.1901086 ↗
- Languages:
- English
- ISSNs:
- 1025-5842
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.100250
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19692.xml