Bicuspid aortic valve repair: outcomes after 17 years of experience. (23rd April 2021)
- Record Type:
- Journal Article
- Title:
- Bicuspid aortic valve repair: outcomes after 17 years of experience. (23rd April 2021)
- Main Title:
- Bicuspid aortic valve repair: outcomes after 17 years of experience
- Authors:
- Jasinski, Marek J
Kosiorowska, Kinga
Gocol, Radoslaw
Jasinski, Jakub
Nowicki, Rafal
Bielicki, Grzegorz
Berezowski, Mikolaj
Przybylski, Roman
Obremska, Marta
Lukaszewski, Marceli
Larysz, Anna
Kansy, Andrzej
Deja, Marek A - Abstract:
- Abstract: : OBJECTIVES: This study presents the results of 17 years of experience with bicuspid aortic valve (BAV) repair and the analysis of factors associated with repair failure and early echocardiographic outcome. METHODS: Between 2003 and 2020, a total of 206 patients [mean age: 44.5 ± 15.2 years; 152 males (74%)] with BAV insufficiency with or without aortic dilatation underwent elective aortic valve repair performed by a single surgeon with a mean follow-up of 5 ± 3.5 years. The transthoracic echocardiography examinations were reported. RESULTS: There were no deaths during the hospital stay, and all but 1 patient survived the follow-up period (99.5%). Overall, 10 patients (5%) developed severe insufficiency and 2 (1%) developed aortic dilatation requiring reoperation. Freedom from reoperation at 7 years reached 91.8%. Type 2 BAV configuration [hazard ratio (HR) 3.9; 95% confidence interval (CI): 1.01–60; P = 0.049], no sinotubular junction remodelling (HR 7; 95% CI: 1.7–23; P = 0.005), no circumferential annuloplasty (HR 3.9; 95% CI: 1.01–64; P = 0.047) and leaflet resection (HR 5.7; 95% CI 1.2–13. P = 0.017) have been identified as a risk factor of redo operation. Parameters of the postoperative left ventricle reverse remodelling improved significantly early after the operation and later at 2 years evaluation. CONCLUSIONS: The repair of BAV offers good short- and mid-term results providing a significant reverse left ventricular remodelling. Type 0 BAVAbstract: : OBJECTIVES: This study presents the results of 17 years of experience with bicuspid aortic valve (BAV) repair and the analysis of factors associated with repair failure and early echocardiographic outcome. METHODS: Between 2003 and 2020, a total of 206 patients [mean age: 44.5 ± 15.2 years; 152 males (74%)] with BAV insufficiency with or without aortic dilatation underwent elective aortic valve repair performed by a single surgeon with a mean follow-up of 5 ± 3.5 years. The transthoracic echocardiography examinations were reported. RESULTS: There were no deaths during the hospital stay, and all but 1 patient survived the follow-up period (99.5%). Overall, 10 patients (5%) developed severe insufficiency and 2 (1%) developed aortic dilatation requiring reoperation. Freedom from reoperation at 7 years reached 91.8%. Type 2 BAV configuration [hazard ratio (HR) 3.9; 95% confidence interval (CI): 1.01–60; P = 0.049], no sinotubular junction remodelling (HR 7; 95% CI: 1.7–23; P = 0.005), no circumferential annuloplasty (HR 3.9; 95% CI: 1.01–64; P = 0.047) and leaflet resection (HR 5.7; 95% CI 1.2–13. P = 0.017) have been identified as a risk factor of redo operation. Parameters of the postoperative left ventricle reverse remodelling improved significantly early after the operation and later at 2 years evaluation. CONCLUSIONS: The repair of BAV offers good short- and mid-term results providing a significant reverse left ventricular remodelling. Type 0 BAV preoperative configuration, circumferential annuloplasty and sinotubular junction remodelling are associated with better repair durability. … (more)
- Is Part Of:
- European journal of cardio-thoracic surgery. Volume 60:Number 5(2021)
- Journal:
- European journal of cardio-thoracic surgery
- Issue:
- Volume 60:Number 5(2021)
- Issue Display:
- Volume 60, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 60
- Issue:
- 5
- Issue Sort Value:
- 2021-0060-0005-0000
- Page Start:
- 1053
- Page End:
- 1061
- Publication Date:
- 2021-04-23
- Subjects:
- Aortic valve repair -- Bicuspid aortic valve -- Repair failure risk factors
Heart -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
617.54 - Journal URLs:
- http://ejcts.oxfordjournals.org/ ↗
http://www.sciencedirect.com/science/journal/10107940 ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ejcts/ezab176 ↗
- Languages:
- English
- ISSNs:
- 1010-7940
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.725620
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19687.xml