90 Invasive acute haemodynamic response to guide LV lead implantation predicts chronic remodelling in patients undergoing cardiac resynchronisation therapy. (9th June 2011)
- Record Type:
- Journal Article
- Title:
- 90 Invasive acute haemodynamic response to guide LV lead implantation predicts chronic remodelling in patients undergoing cardiac resynchronisation therapy. (9th June 2011)
- Main Title:
- 90 Invasive acute haemodynamic response to guide LV lead implantation predicts chronic remodelling in patients undergoing cardiac resynchronisation therapy
- Authors:
- Duckett, S G
Ginks, M
Shetty, A
Bostock, J
Gill, J S
Hamid, S G
Kapetanakis, S
Cunliffe, E
Razavi, R S
Carr-White, G
Rinaldi, C A - Abstract:
- Abstract : Introduction: Cardiac resynchronisation therapy (CRT) reduces mortality and morbidity in heart failure patients, however up to 30% of patients do not derive symptomatic benefit. Higher proportions do not remodel. Multi-centre trials have shown echocardiographic techniques are poor at improving response rates. We hypothesised that the degree of acute haemodynamic response (AHR) at implant can predict which patients remodel. We evaluated the relationship between AHR and reverse remodelling (RR) in CRT. Methods 33 patients undergoing CRT (21 dilated & 12 ischaemic cardiomyopathy) were studied. Left ventricular (LV) volumes were assessed pre and post CRT. AHR (LV-dP/dtmax) was assessed at implant using a pressure wire in the LV cavity. The LV lead was placed in potential target veins and the largest percentage rise in LV-dP/dtmax from baseline (AAI or RV pacing with atrial fibrillation) to DDDLV was used to determine optimal LV lead position. RR was defined as reduction in LV end systolic volume (ESV) ≥15% at 6 months. Results: LV-dP/dtmax increased significantly from baseline (801±194 mm Hg/s to 924±203 mm Hg/s (p<0.001)) with DDDLV pacing for the optimal LV lead position. There was a significant difference in the percentage rise in LV-dP/dtmax between the best and worst LV lead position (Abstract 90 figure 1 ). LVESV decreased from 186±68 ml to 157±68 ml (p<0.001). 18 (56%) patients exhibited RR. There was a significant relationship between percentage rise inAbstract : Introduction: Cardiac resynchronisation therapy (CRT) reduces mortality and morbidity in heart failure patients, however up to 30% of patients do not derive symptomatic benefit. Higher proportions do not remodel. Multi-centre trials have shown echocardiographic techniques are poor at improving response rates. We hypothesised that the degree of acute haemodynamic response (AHR) at implant can predict which patients remodel. We evaluated the relationship between AHR and reverse remodelling (RR) in CRT. Methods 33 patients undergoing CRT (21 dilated & 12 ischaemic cardiomyopathy) were studied. Left ventricular (LV) volumes were assessed pre and post CRT. AHR (LV-dP/dtmax) was assessed at implant using a pressure wire in the LV cavity. The LV lead was placed in potential target veins and the largest percentage rise in LV-dP/dtmax from baseline (AAI or RV pacing with atrial fibrillation) to DDDLV was used to determine optimal LV lead position. RR was defined as reduction in LV end systolic volume (ESV) ≥15% at 6 months. Results: LV-dP/dtmax increased significantly from baseline (801±194 mm Hg/s to 924±203 mm Hg/s (p<0.001)) with DDDLV pacing for the optimal LV lead position. There was a significant difference in the percentage rise in LV-dP/dtmax between the best and worst LV lead position (Abstract 90 figure 1 ). LVESV decreased from 186±68 ml to 157±68 ml (p<0.001). 18 (56%) patients exhibited RR. There was a significant relationship between percentage rise in LV-dP/dtmax and RR for DDDLV pacing (p<0.001) (Abstract 90 figure 2 ). A similar relationship for AHR and RR in DCM and ICM (p=0.01 & p=0.006) was seen. Conclusions: Acute haemodynamic response to LV pacing is useful for predicting which patients are likely to remodel in response to CRT both for DCM and ICM. There is much variation in the rise in LV-dP/dtmax depending on LV lead position. Using acute haemodynamic response measured with a pressure wire during CRT implant has the potential to guide LV lead positioning and improve response rates in the future. … (more)
- Is Part Of:
- Heart. Volume 97(2011)Supplement 1
- Journal:
- Heart
- Issue:
- Volume 97(2011)Supplement 1
- Issue Display:
- Volume 97, Issue 1 (2011)
- Year:
- 2011
- Volume:
- 97
- Issue:
- 1
- Issue Sort Value:
- 2011-0097-0001-0000
- Page Start:
- A52
- Page End:
- A53
- Publication Date:
- 2011-06-09
- Subjects:
- Cardiac resynchronisation therapy -- acute haemodynamic response -- reverse remodelling
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2011-300198.90 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19681.xml