Novel Supreme Drug-Eluting Stents With Early Synchronized Antiproliferative Drug Delivery to Inhibit Smooth Muscle Cell Proliferation After Drug-Eluting Stents Implantation in Coronary Artery Disease: Results of the PIONEER III Randomized Clinical Trial. Issue 22 (6th April 2021)
- Record Type:
- Journal Article
- Title:
- Novel Supreme Drug-Eluting Stents With Early Synchronized Antiproliferative Drug Delivery to Inhibit Smooth Muscle Cell Proliferation After Drug-Eluting Stents Implantation in Coronary Artery Disease: Results of the PIONEER III Randomized Clinical Trial. Issue 22 (6th April 2021)
- Main Title:
- Novel Supreme Drug-Eluting Stents With Early Synchronized Antiproliferative Drug Delivery to Inhibit Smooth Muscle Cell Proliferation After Drug-Eluting Stents Implantation in Coronary Artery Disease
- Authors:
- Lansky, Alexandra J.
Kereiakes, Dean J.
Baumbach, Andreas
Windecker, Stephan
Hussain, Yasin
Pietras, Cody
Dressler, Ovidiu
Issever, Ozgu
Curtis, Michael
Bertolet, Barry
Zidar, James P.
Smits, Pieter C.
Alfonso Jiménez Díaz, Victor
McLaurin, Brent
Hofma, Sjoerd
Cequier, Ángel
Dib, Nabil
Benit, Edouard
Mathur, Anthony
Brogno, David
Berland, Jacques
Wykrzykowska, Joanna
Piegari, Guy
Brugaletta, Salvatore
Saito, Shigeru
Leon, Martin B. - Abstract:
- Abstract : Supplemental Digital Content is available in the text. Abstract : Background: Accelerated endothelial healing after targeted antiproliferative drug delivery may limit the long-term inflammatory response of drug-eluting stents (DESs). The novel Supreme DES is designed to synchronize early drug delivery within 4 to 6 weeks of implantation, leaving behind a prohealing permanent base layer. Whether the Supreme DES is safe and effective in the short term and can improve long-term clinical outcomes is not known. Methods: In an international, 2:1 randomized, single-blind trial, we compared treatment with Supreme DES to durable polymer everolimus-eluting stents (DP-EES) in patients with acute and chronic coronary syndromes. The primary end point was target lesion failure—a composite of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. The trial was designed to demonstrate noninferiority (margin of 3.58%) of the Supreme DES at 12 months compared with DP-EES (URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03168776). Results: From October 2017 to July 2019, a total of 1629 patients were randomly assigned (2:1) to the Supreme DES (N=1086) or DP-EES (N=543). At 12 months, target lesion failure occurred in 57 of 1057 patients (5.4%) in the Supreme DES group and in 27 of 532 patients (5.1%) in the DP-EES group (absolute risk difference, 0.32% [95% CI, −1.87 to 2.5]; P non inferiority =0.002]. There were noAbstract : Supplemental Digital Content is available in the text. Abstract : Background: Accelerated endothelial healing after targeted antiproliferative drug delivery may limit the long-term inflammatory response of drug-eluting stents (DESs). The novel Supreme DES is designed to synchronize early drug delivery within 4 to 6 weeks of implantation, leaving behind a prohealing permanent base layer. Whether the Supreme DES is safe and effective in the short term and can improve long-term clinical outcomes is not known. Methods: In an international, 2:1 randomized, single-blind trial, we compared treatment with Supreme DES to durable polymer everolimus-eluting stents (DP-EES) in patients with acute and chronic coronary syndromes. The primary end point was target lesion failure—a composite of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. The trial was designed to demonstrate noninferiority (margin of 3.58%) of the Supreme DES at 12 months compared with DP-EES (URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03168776). Results: From October 2017 to July 2019, a total of 1629 patients were randomly assigned (2:1) to the Supreme DES (N=1086) or DP-EES (N=543). At 12 months, target lesion failure occurred in 57 of 1057 patients (5.4%) in the Supreme DES group and in 27 of 532 patients (5.1%) in the DP-EES group (absolute risk difference, 0.32% [95% CI, −1.87 to 2.5]; P non inferiority =0.002]. There were no significant differences in rates of device success, clinically driven target lesion revascularization, or stent thrombosis at 12 months, and the safety composite of cardiovascular death and target vessel myocardial infarction was 3.5% versus 4.6% (hazard ratio, 0.76 [95% CI, 0.46–1.25]) with Supreme DES compared with DP-EES, although rates of combined clinically and non–clinically driven target lesion revascularization at 12 months were higher with Supreme DES. Conclusions: Among patients with acute and chronic coronary syndromes undergoing percutaneous coronary intervention, the Supreme DES proved to be noninferior to the standard DP-EES. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03168776. … (more)
- Is Part Of:
- Circulation. Volume 143:Issue 22(2021)
- Journal:
- Circulation
- Issue:
- Volume 143:Issue 22(2021)
- Issue Display:
- Volume 143, Issue 22 (2021)
- Year:
- 2021
- Volume:
- 143
- Issue:
- 22
- Issue Sort Value:
- 2021-0143-0022-0000
- Page Start:
- 2143
- Page End:
- 2154
- Publication Date:
- 2021-04-06
- Subjects:
- acute coronary syndrome -- drug-eluting stents -- single-blind method -- stents
Blood -- Circulation -- Periodicals
Cardiovascular system -- Periodicals
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
Blood Circulation
Cardiovascular System
Vascular Diseases
616.1 - Journal URLs:
- http://ovidsp.tx.ovid.com/sp-3.4.2a/ovidweb.cgi?&S=HFFJFPCLPODDKOLGNCALDCMCIACKAA00&Browse=Toc+Children%7cNO%7cS.sh.1384_1326796138_84.1384_1326796138_96.1384_1326796138_97%7c66%7c50 ↗
http://www.circulationaha.org ↗
http://circ.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCULATIONAHA.120.052482 ↗
- Languages:
- English
- ISSNs:
- 0009-7322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19680.xml