Implantable cardiac defibrillator and mortality in non-ischaemic cardiomyopathy: an updated meta-analysis. Issue 3 (5th August 2017)
- Record Type:
- Journal Article
- Title:
- Implantable cardiac defibrillator and mortality in non-ischaemic cardiomyopathy: an updated meta-analysis. Issue 3 (5th August 2017)
- Main Title:
- Implantable cardiac defibrillator and mortality in non-ischaemic cardiomyopathy: an updated meta-analysis
- Authors:
- Alba, Ana C
Foroutan, Farid
Duero Posada, Juan
Battioni, Luciano
Schofield, Toni
Alhussein, Mosaad
Agoritsas, Thomas
Spencer, Frederick A
Guyatt, Gordon - Abstract:
- Abstract : Objectives: The benefit of implantable cardiac defibrillator (ICD) in symptomatic patients with systolic dysfunction and non-ischaemic cardiomyopathy remains controversial. We conducted a systematic review and meta-analysis to determine the effect of ICD in patients with non-ischaemic cardiomyopathy on (1) all-cause mortality, (2) cardiovascular mortality and (3) sudden cardiac death. Methods: We searched citations in meta-analyses published until 2012, and in MEDLINE, Embase, PubMed and Cochrane databases from 2012 to October 2016. We included randomised controlled trials (RCTs) evaluating the effect of ICD therapy on all-cause and cardiovascular mortality and sudden cardiac death in patients with non-ischaemic cardiomyopathy. Independent reviewers evaluated study eligibility, abstracted data and assessed risk of bias in duplicate. We used random-effect models to meta-analyse relative risks (RR) and hazard ratios (HR) across studies, the Grades of Recommendation, Assessment, Development, and Evaluation system to quantify absolute effects and quality of evidence, and I 2 to evaluate heterogeneity. Results: We identified six RCTs including 1715 patients experiencing 421 deaths. ICD therapy was associated with reduced overall mortality (HR 0.78, 95% CI 0.66 to 0.92, I 2 = 0%, risk difference 4.7%, high quality), cardiovascular mortality (RR 0.77, 95% CI 0.60 to 0.98, I 2 = 39%, risk difference 3.3%, high quality) and sudden cardiac death (RR 0.45, 95% CI 0.29 toAbstract : Objectives: The benefit of implantable cardiac defibrillator (ICD) in symptomatic patients with systolic dysfunction and non-ischaemic cardiomyopathy remains controversial. We conducted a systematic review and meta-analysis to determine the effect of ICD in patients with non-ischaemic cardiomyopathy on (1) all-cause mortality, (2) cardiovascular mortality and (3) sudden cardiac death. Methods: We searched citations in meta-analyses published until 2012, and in MEDLINE, Embase, PubMed and Cochrane databases from 2012 to October 2016. We included randomised controlled trials (RCTs) evaluating the effect of ICD therapy on all-cause and cardiovascular mortality and sudden cardiac death in patients with non-ischaemic cardiomyopathy. Independent reviewers evaluated study eligibility, abstracted data and assessed risk of bias in duplicate. We used random-effect models to meta-analyse relative risks (RR) and hazard ratios (HR) across studies, the Grades of Recommendation, Assessment, Development, and Evaluation system to quantify absolute effects and quality of evidence, and I 2 to evaluate heterogeneity. Results: We identified six RCTs including 1715 patients experiencing 421 deaths. ICD therapy was associated with reduced overall mortality (HR 0.78, 95% CI 0.66 to 0.92, I 2 = 0%, risk difference 4.7%, high quality), cardiovascular mortality (RR 0.77, 95% CI 0.60 to 0.98, I 2 = 39%, risk difference 3.3%, high quality) and sudden cardiac death (RR 0.45, 95% CI 0.29 to 0.70, I 2 = 0%, risk difference 4.1%, high quality). The benefit of ICD was not influenced by the use of amiodarone in the comparison group, the duration of follow-up, by use of β-blockers and ACE inhibitors/angiotensin receptor blocker or cardiac resynchronisation therapy. Conclusion: Primary prevention ICD therapy reduces all-cause and cardiovascular mortality and sudden cardiac death in patients with non-ischaemic cardiomyopathy. … (more)
- Is Part Of:
- Heart. Volume 104:Issue 3(2018)
- Journal:
- Heart
- Issue:
- Volume 104:Issue 3(2018)
- Issue Display:
- Volume 104, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 104
- Issue:
- 3
- Issue Sort Value:
- 2018-0104-0003-0000
- Page Start:
- 230
- Page End:
- 236
- Publication Date:
- 2017-08-05
- Subjects:
- implanted cardiac defibrillator -- heart failure with reduced ejection fraction -- idiopathic dilated cardiomyopathy -- meta-analysis and study design
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2017-311430 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19673.xml