First standardised field sobriety test in Brazil. (7th October 2012)
- Record Type:
- Journal Article
- Title:
- First standardised field sobriety test in Brazil. (7th October 2012)
- Main Title:
- First standardised field sobriety test in Brazil
- Authors:
- Sousa, TRV
Chandran, A
Schmitz, AR
Pasa, GG
Gonçalves, VM
Bastos, TM
Seiffert, BE
Hyder, A
Pechansky, F - Abstract:
- Abstract : Background: In Brazil, drivers are subject to arrest if they are found driving with a blood alcohol concentration (BAC) over 0.06%. At BACs between 0.02% and 0.06%, they have their driver's license withheld. The use of a field sobriety test would be an appropriate alternative in the absence of a breathalyzer or to test for other psychoactive substances. This study reflects the first experience with the Standardised Field Sobriety Test (SFST) in Brazil. Aim: To determine the accuracy of the application of the first Standardised Field Sobriety Test conducted in Brazil. Method: During police roadblocks, self-trained researchers applied the SFST on volunteer drivers (N=718), using the standardised 3-test battery (Horizontal-Gaze-Nystagmus, Walk-and-Turn, One-Leg Stand). A questionnaire on alcohol consumption and driver behaviour was conducted by researchers and the breathalyzer test was conducted by police officers (16.4% refused to perform it). Results: The breathalyzer test confirmed that of the drivers with BAC above 0.08%, 86% failed in the SFST, which resulted in 58% accuracy. However, considering the BAC limit in Brazil (0.06%), we have similar accuracy (57.9%): 70% of the drivers failed at least one of the standardised 3-test. These tests were conducted in two rounds, allowing researchers to hone their skills, which resulted in higher accuracy in the second round (65.1%). Significance: The SFSTs are valid tests that are feasible to use in field situations inAbstract : Background: In Brazil, drivers are subject to arrest if they are found driving with a blood alcohol concentration (BAC) over 0.06%. At BACs between 0.02% and 0.06%, they have their driver's license withheld. The use of a field sobriety test would be an appropriate alternative in the absence of a breathalyzer or to test for other psychoactive substances. This study reflects the first experience with the Standardised Field Sobriety Test (SFST) in Brazil. Aim: To determine the accuracy of the application of the first Standardised Field Sobriety Test conducted in Brazil. Method: During police roadblocks, self-trained researchers applied the SFST on volunteer drivers (N=718), using the standardised 3-test battery (Horizontal-Gaze-Nystagmus, Walk-and-Turn, One-Leg Stand). A questionnaire on alcohol consumption and driver behaviour was conducted by researchers and the breathalyzer test was conducted by police officers (16.4% refused to perform it). Results: The breathalyzer test confirmed that of the drivers with BAC above 0.08%, 86% failed in the SFST, which resulted in 58% accuracy. However, considering the BAC limit in Brazil (0.06%), we have similar accuracy (57.9%): 70% of the drivers failed at least one of the standardised 3-test. These tests were conducted in two rounds, allowing researchers to hone their skills, which resulted in higher accuracy in the second round (65.1%). Significance: The SFSTs are valid tests that are feasible to use in field situations in Brazil, serving as indicators of the presence of alcohol or other substances. The use of the SFST as legal evidence could improve enforcement in Brazil. … (more)
- Is Part Of:
- Injury prevention. Volume 18(2012)Supplement 1
- Journal:
- Injury prevention
- Issue:
- Volume 18(2012)Supplement 1
- Issue Display:
- Volume 18, Issue 1 (2012)
- Year:
- 2012
- Volume:
- 18
- Issue:
- 1
- Issue Sort Value:
- 2012-0018-0001-0000
- Page Start:
- A174
- Page End:
- A174
- Publication Date:
- 2012-10-07
- Subjects:
- Children's accidents -- Prevention -- Periodicals
Accidents -- Prevention -- Periodicals
617.1 - Journal URLs:
- http://ip.bmjjournals.com ↗
http://www.injuryprevention.com ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/injuryprev-2012-040590o.21 ↗
- Languages:
- English
- ISSNs:
- 1353-8047
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19658.xml