107 Enhanced endothelial cell coverage on graphene coated stents. (June 2018)
- Record Type:
- Journal Article
- Title:
- 107 Enhanced endothelial cell coverage on graphene coated stents. (June 2018)
- Main Title:
- 107 Enhanced endothelial cell coverage on graphene coated stents
- Authors:
- Jafarzadeh, Fatemeh
McManus, Daryl
Barbolina, Irina
Kostarelos, Kostas
Malik, Nadim
Casiraghi, Cinzia
Holt, Cathy M - Abstract:
- Abstract : Introduction: Coronary artery disease is the leading cause of death worldwide. Stent implantation is performed widely to revascularise stenosed coronary arteries. Restenosis is a significant complication associated with bare metal stents (BMS). Drug eluting stents with adjunct anti-platelet therapy significantly improved restenosis risk but introduced late in stent thrombosis. Therefore, there remains a need for more effective coronary artery stents and the aim of this study is to improve currently available BMSs. Graphene is a 2D material consisting of a layer of hexagonal structured carbon atoms, exhibiting unique properties, ideal for implantable device coatings: it forms an impermeable membrane, is atomically smooth and has a Daruyhigh surface to volume ratio. We have coated currently available BMSs with graphene-based materials to enhance re-endothelialisation and hinder the formation of intimal hyperplasia resulting from possible aetiologies such as metal leaching or inflammatory reaction to the metal itself. Methods: Graphene-based bare metal stent coatings were optimised by investigating several coating methods. Human coronary artery endothelial cells (HCAECs) were cultured on control and coated stents. Cells were fixed at day 0 and day 8 post-seeding, followed by Hoechst 33 342 and Phalloidin staining for viewing under the fluorescence microscope. Subsequently, HCAEC number per mm2 area of stent was determined at both day 0 and day 8, and the differenceAbstract : Introduction: Coronary artery disease is the leading cause of death worldwide. Stent implantation is performed widely to revascularise stenosed coronary arteries. Restenosis is a significant complication associated with bare metal stents (BMS). Drug eluting stents with adjunct anti-platelet therapy significantly improved restenosis risk but introduced late in stent thrombosis. Therefore, there remains a need for more effective coronary artery stents and the aim of this study is to improve currently available BMSs. Graphene is a 2D material consisting of a layer of hexagonal structured carbon atoms, exhibiting unique properties, ideal for implantable device coatings: it forms an impermeable membrane, is atomically smooth and has a Daruyhigh surface to volume ratio. We have coated currently available BMSs with graphene-based materials to enhance re-endothelialisation and hinder the formation of intimal hyperplasia resulting from possible aetiologies such as metal leaching or inflammatory reaction to the metal itself. Methods: Graphene-based bare metal stent coatings were optimised by investigating several coating methods. Human coronary artery endothelial cells (HCAECs) were cultured on control and coated stents. Cells were fixed at day 0 and day 8 post-seeding, followed by Hoechst 33 342 and Phalloidin staining for viewing under the fluorescence microscope. Subsequently, HCAEC number per mm2 area of stent was determined at both day 0 and day 8, and the difference calculated. One-Way ANOVA with multiple comparison was performed and p<0.05 considered as statistically significance. Results are shown as mean± SEM. Results: A spray coating method was selected for providing optimal coverage of graphene-based coating on BMSs. HCAEC count/mm2 was significantly more on the Graphene-based coating of the bare metal stent (1085±156 HCAEC count/mm2) compared to the uncoated control bare metal stent (486±130 HCAEC count/mm2) p=0.0063, n=3. Conclusion: An optimised prototype of graphene-based BMS coating was produced for preclinical evaluation. Increased HCAEC count per mm2 of graphene-based coated BMS was observed in comparison to the uncoated bare metal stents. These data provide the first indication of the potential feasibility of graphene-based materials as coatings on implantable coronary artery stents. … (more)
- Is Part Of:
- Heart. Volume 104(2018)Supplement 6
- Journal:
- Heart
- Issue:
- Volume 104(2018)Supplement 6
- Issue Display:
- Volume 104, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 104
- Issue:
- 6
- Issue Sort Value:
- 2018-0104-0006-0000
- Page Start:
- A84
- Page End:
- A85
- Publication Date:
- 2018-06
- Subjects:
- Coronary artery disease -- Stents -- Graphene
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2018-BCS.106 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19680.xml