124 Stroke volume determined flow reserve does not predict the true severity of low-flow low-gradient aortic stenosis and is not a robust marker of contractile reserve in patients undergoing low-dose dobutamine echocardiography. (5th June 2017)
- Record Type:
- Journal Article
- Title:
- 124 Stroke volume determined flow reserve does not predict the true severity of low-flow low-gradient aortic stenosis and is not a robust marker of contractile reserve in patients undergoing low-dose dobutamine echocardiography. (5th June 2017)
- Main Title:
- 124 Stroke volume determined flow reserve does not predict the true severity of low-flow low-gradient aortic stenosis and is not a robust marker of contractile reserve in patients undergoing low-dose dobutamine echocardiography
- Authors:
- Vamvakidou, Anastasia
Chahal, Navtej
Hampson, Reinette
Gurunathan, Sothinathan
Karogiannis, Nikos
Li, Wei
Banfield, Ann
Khattar, Rajdeep
Senior, Roxy - Abstract:
- Abstract : Background: During low-dose dobutamine stress echocardiography (LDDSE) in low-flow low-gradient aortic stenosis (LFLGAS), both the aortic stenosis (AS) severity and the presence of contractile reserve (CR) are conventionally assessed based on stroke volume flow reserve (SVFR), which is defined as stroke volume [SV] increase 20%. However frequent exaggerated chronotropic response to dobutamine with shortening left ventricular time result in SV drop. On the contrary, transvalvular flow rate (FR) (SV/ejection time) and left ventricular ejection fraction (LVEF) may increase. We aimed to assess the value of FR 200 ml/s (normal FR) and LVEF change in the identification of true severe AS (TSAS) and the assessment of CR respectively. Methods: Accordingly 74 consecutive patients (mean age 78 years) with LFLGAS referred for LDDSE for determination of AS severity and CR underwent retrospective assessment of SV, FR, LVEF and standard echocardiographic parameters of AS severity (Table 1). The outcome assessed was all-cause mortality censored for aortic valve intervention. Results: SVFR was present in 30 (40.5%) of the 74 patients whereas FR 200 ml/s was achieved in 60 (81.1%) (p<0.001). During the median follow-up of 316.5 days 28 (37.8%) deaths occurred. Amongst all standard echocardiographic predictors of AS severity at peak stress (aortic valve mean and peak gradient, peak velocity and area [AVA]) and clinical prognostic factors, AVA was an independent predictor of deathAbstract : Background: During low-dose dobutamine stress echocardiography (LDDSE) in low-flow low-gradient aortic stenosis (LFLGAS), both the aortic stenosis (AS) severity and the presence of contractile reserve (CR) are conventionally assessed based on stroke volume flow reserve (SVFR), which is defined as stroke volume [SV] increase 20%. However frequent exaggerated chronotropic response to dobutamine with shortening left ventricular time result in SV drop. On the contrary, transvalvular flow rate (FR) (SV/ejection time) and left ventricular ejection fraction (LVEF) may increase. We aimed to assess the value of FR 200 ml/s (normal FR) and LVEF change in the identification of true severe AS (TSAS) and the assessment of CR respectively. Methods: Accordingly 74 consecutive patients (mean age 78 years) with LFLGAS referred for LDDSE for determination of AS severity and CR underwent retrospective assessment of SV, FR, LVEF and standard echocardiographic parameters of AS severity (Table 1). The outcome assessed was all-cause mortality censored for aortic valve intervention. Results: SVFR was present in 30 (40.5%) of the 74 patients whereas FR 200 ml/s was achieved in 60 (81.1%) (p<0.001). During the median follow-up of 316.5 days 28 (37.8%) deaths occurred. Amongst all standard echocardiographic predictors of AS severity at peak stress (aortic valve mean and peak gradient, peak velocity and area [AVA]) and clinical prognostic factors, AVA was an independent predictor of death (HR=0.1, 95%CI=0.02–0.7, p=0.03), and was therefore used to define TSAS (stress AVA 1.01cm 2 ). TSAS was present in 47 (63.5%) patients of whom SVFR correctly identified 17 (36.2%) compared to 34 (72.3%) with FR 200 ml/s (p=0.001). In the 48 patients with LVEF 50%, amongst SV, FR and LVEF changes, only the latter was an independent predictor of death (HR=0.92, 95% CI=0.87–0.98, p=0.02) (Table 2). LVEF change of <5% was the best cut-off for the prediction of death (log rank p=0.004) and therefore for determination of CR (Figures 1-2). Increase in LVEF 5% had a significant impact on survival both on patients that underwent aortic valve intervention (log rank p=0.03) and those who underwent medical management (log rank p=0.01), as opposed to presence of SVFR (log rank p=0.234 and p=0.708 respectively). Conclusions: During LDDSE in LFLGAS normalised FR, not SVFR, is a better determinant of TSAS, whereas assessment of LVEF change instead of SVFR determines CR. … (more)
- Is Part Of:
- Heart. Volume 103(2017)Supplement 5
- Journal:
- Heart
- Issue:
- Volume 103(2017)Supplement 5
- Issue Display:
- Volume 103, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 103
- Issue:
- 5
- Issue Sort Value:
- 2017-0103-0005-0000
- Page Start:
- A94
- Page End:
- A95
- Publication Date:
- 2017-06-05
- Subjects:
- low-flow low-gradient aortic stenosis -- low-dose dobutamine stress echocardiography -- contractile reserve
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2017-311726.123 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19676.xml