123 Doppler assessment of aortic stenosis: reading the peak velocity is superior to velocity time integral. (5th June 2017)
- Record Type:
- Journal Article
- Title:
- 123 Doppler assessment of aortic stenosis: reading the peak velocity is superior to velocity time integral. (5th June 2017)
- Main Title:
- 123 Doppler assessment of aortic stenosis: reading the peak velocity is superior to velocity time integral
- Authors:
- Cole, Graham
Sacchi, Stefania
Dhutia, Niti
Shun-Shin, Matthew
Zolgharni, Massoud
Sutaria, Nilesh
Francis, Darrel - Abstract:
- Abstract : Introduction: Previous studies of the reproducibility of echocardiographic assessment of aortic stenosis have compared only a pair of observers. The aim of this study was to assess reproducibility across a large group of observers and compare the reproducibility of reading the peak versus the velocity time integral. Methods: 25 observers reviewed continuous wave (CW) aortic valve and pulsed wave (PW) LVOT Doppler traces from 20 sequential cases of aortic stenosis in random order. Each operator unknowingly measured the peak velocity and velocity time integral (VTI) twice for each case, with the traces stored for analysis. We undertook a mixed-model analysis of the sources of variance for peak and VTI measurements. Results: Measuring the peak is more reproducible than VTI for both PW (coefficient of variation 9.6% versus 15.9%, p<0.001) and CW traces (coefficient of variation 4.0% versus 9.6%, p<0.001), as shown in Figure 1. VTI is inferior because, compared to the middle, it is difficult to reproducibly trace the steep beginning (standard deviation 3.7x and 1.8x larger for CW and PW respectively) and end (standard deviation 2.4x and 1.5x larger for CW and PW respectively). Dimensionless index reduces the coefficient of variation (19% reduction for VTI, 11% reduction for peak) partly because it cancels correlated errors: an operator who over-measures a CW trace is likely to over-measure the matching PW trace (r=0.39, p<0.001 for VTI, r=0.41, p<0.001 for peak), asAbstract : Introduction: Previous studies of the reproducibility of echocardiographic assessment of aortic stenosis have compared only a pair of observers. The aim of this study was to assess reproducibility across a large group of observers and compare the reproducibility of reading the peak versus the velocity time integral. Methods: 25 observers reviewed continuous wave (CW) aortic valve and pulsed wave (PW) LVOT Doppler traces from 20 sequential cases of aortic stenosis in random order. Each operator unknowingly measured the peak velocity and velocity time integral (VTI) twice for each case, with the traces stored for analysis. We undertook a mixed-model analysis of the sources of variance for peak and VTI measurements. Results: Measuring the peak is more reproducible than VTI for both PW (coefficient of variation 9.6% versus 15.9%, p<0.001) and CW traces (coefficient of variation 4.0% versus 9.6%, p<0.001), as shown in Figure 1. VTI is inferior because, compared to the middle, it is difficult to reproducibly trace the steep beginning (standard deviation 3.7x and 1.8x larger for CW and PW respectively) and end (standard deviation 2.4x and 1.5x larger for CW and PW respectively). Dimensionless index reduces the coefficient of variation (19% reduction for VTI, 11% reduction for peak) partly because it cancels correlated errors: an operator who over-measures a CW trace is likely to over-measure the matching PW trace (r=0.39, p<0.001 for VTI, r=0.41, p<0.001 for peak), as shown in Figure 2. Conclusions: It is more reproducible to measure the peak of a Doppler trace than the VTI, because it is difficult to trace the steep slopes at the beginning and end reproducibly. The difference is non-trivial: an average operator would be 95% confident detecting a 11.1% change in peak velocity but a much larger 27.4% change in VTI. A clinical trial of an intervention for aortic stenosis with a VTI endpoint would need to be 2.4 times larger than one with a peak velocity endpoint. Part of the benefit of dimensionless index in improving reproducibility arises because it cancels individual operators tendency to consistently over- or under-read traces. … (more)
- Is Part Of:
- Heart. Volume 103(2017)Supplement 5
- Journal:
- Heart
- Issue:
- Volume 103(2017)Supplement 5
- Issue Display:
- Volume 103, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 103
- Issue:
- 5
- Issue Sort Value:
- 2017-0103-0005-0000
- Page Start:
- A93
- Page End:
- A93
- Publication Date:
- 2017-06-05
- Subjects:
- Echocardiography -- valvular heart disease -- reproducibility
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2017-311726.122 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19675.xml