113 Novel diagnostic criterion for microvascular ischaemia using cmr perfusion imaging: validation against invasive index of microvascular resistance. (5th June 2017)
- Record Type:
- Journal Article
- Title:
- 113 Novel diagnostic criterion for microvascular ischaemia using cmr perfusion imaging: validation against invasive index of microvascular resistance. (5th June 2017)
- Main Title:
- 113 Novel diagnostic criterion for microvascular ischaemia using cmr perfusion imaging: validation against invasive index of microvascular resistance
- Authors:
- Liu, Alexander
Wijesurendra, Rohan
M Liu, Joanna
C Forfar, John
M Channon, Keith
Neubauer, Stefan
K Piechnik, Stefan
K Kharbanda, Rajesh
M Ferreira, Vanessa - Abstract:
- Abstract : Background: In over 50% of patients with angina, the underlying ischaemia is related to microvascular dysfunction (MVD), rather than epicardial coronary artery disease (CAD). Clinically, MVD remains a major diagnostic challenge, which hinders targeted therapy and confers impaired clinical outcomes. Myocardial perfusion reserve (MPR), as assessed by cardiovascular magnetic resonance (CMR), is impaired in those with microvascular angina. We sought to objectively diagnose microvascular ischaemia using CMR by defining an MPR cut-off, validated against invasive coronary microvascular physiology (Index of Microvascular Resistance, IMR). Methods: 75 subjects (50 patients with angina and suspected CAD; 25 healthy controls) underwent CMR to assess LV function, MPR (adenosine stress/rest first-pass perfusion imaging) and viability (late gadolinium enhancement). All patients underwent invasive coronary angiography with pressure-wire assessment of IMR and fractional flow reserve (FFR). A total of 120 coronary arteries were assessed. CMR images were analysed by observers blinded to clinical and angiographic data. MPR was defined as the ratio of stress/rest myocardial signal intensity upslope gradients during gadolinium first-pass perfusion imaging, normalised to LV blood pool enhancement. Infarcted myocardium was identified using LGE and excluded from analysis. Results: For reference, myocardium downstream of significant epicardial stenosis (FFR<0.8) had lower MPR than healthyAbstract : Background: In over 50% of patients with angina, the underlying ischaemia is related to microvascular dysfunction (MVD), rather than epicardial coronary artery disease (CAD). Clinically, MVD remains a major diagnostic challenge, which hinders targeted therapy and confers impaired clinical outcomes. Myocardial perfusion reserve (MPR), as assessed by cardiovascular magnetic resonance (CMR), is impaired in those with microvascular angina. We sought to objectively diagnose microvascular ischaemia using CMR by defining an MPR cut-off, validated against invasive coronary microvascular physiology (Index of Microvascular Resistance, IMR). Methods: 75 subjects (50 patients with angina and suspected CAD; 25 healthy controls) underwent CMR to assess LV function, MPR (adenosine stress/rest first-pass perfusion imaging) and viability (late gadolinium enhancement). All patients underwent invasive coronary angiography with pressure-wire assessment of IMR and fractional flow reserve (FFR). A total of 120 coronary arteries were assessed. CMR images were analysed by observers blinded to clinical and angiographic data. MPR was defined as the ratio of stress/rest myocardial signal intensity upslope gradients during gadolinium first-pass perfusion imaging, normalised to LV blood pool enhancement. Infarcted myocardium was identified using LGE and excluded from analysis. Results: For reference, myocardium downstream of significant epicardial stenosis (FFR<0.8) had lower MPR than healthy controls (1.3±0.4 vs 1.9±0.4, p<0.001, figure 1). Downstream of unobstructed epicardial coronary arteries (FFR>0.8), non-infarcted myocardium had intermediate MPR: (unobstructed-CAD 1.6±0.4, obstructed-CAD 1.3±0.4; controls: 1.9±0.4, p<0.001 by ANOVA). When further stratified by IMR, myocardium with IMR<20 had comparable MPR to normal controls (1.9±0.5 vs 1.9±0.4, p=0.98); as IMR increased, there was progressive reduction in MPR (IMR<20: 1.9±0.5, IMR20-40: 1.5±0.4, IMR>40: 1.3±0.4; all p<0.01 by ANOVA). Myocardium with high IMR>40 but unobstructed epicardial coronary arteries had equivalent MPR to ischaemic myocardium supplied by significant epicardial stenosis (1.3±0.4 vs 1.3±0.4, p=0.48, figure 1). Downstream of unobstructed epicardial coronary arteries of CAD patients, MPR 1.5 detected microvascular ischaemia (defined by IMR>40) with a sensitivity of 82%, specificity of 83%, and accuracy of 83% on ROC analysis (AUC 0.87±0.06, figure 2). Conclusions: Microvascular ischaemia can be objectively diagnosed using CMR perfusion imaging. Reduced MPR is related to increased microvascular resistance, as validated by invasive IMR. The novel MPR criterion of 1.5, to detect high IMR>40, can confirm the clinical diagnosis of microvascular ischaemia, enabling targeted therapy and disease monitoring. … (more)
- Is Part Of:
- Heart. Volume 103(2017)Supplement 5
- Journal:
- Heart
- Issue:
- Volume 103(2017)Supplement 5
- Issue Display:
- Volume 103, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 103
- Issue:
- 5
- Issue Sort Value:
- 2017-0103-0005-0000
- Page Start:
- A85
- Page End:
- A86
- Publication Date:
- 2017-06-05
- Subjects:
- Microvascular ischaemia -- CMR -- IMR
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2017-311726.112 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19676.xml