53 Virtual (computed) FFR and Virtual Coronary Intervention (VCI) vs angiography for guiding PCI: a virtual study. (May 2019)
- Record Type:
- Journal Article
- Title:
- 53 Virtual (computed) FFR and Virtual Coronary Intervention (VCI) vs angiography for guiding PCI: a virtual study. (May 2019)
- Main Title:
- 53 Virtual (computed) FFR and Virtual Coronary Intervention (VCI) vs angiography for guiding PCI: a virtual study
- Authors:
- Gosling, Rebecca
Morris, Paul
Lawford, Patricia
Hose, Rodney
Gunn, Julian - Abstract:
- Abstract : Introduction: Using fractional flow reserve (FFR) to guide percutaneous coronary intervention (PCI) improves outcomes and reduces costs. In FAME, FFR guidance reduced the total length of stent per patient from 52mm to 38mm and the number from 2.7 to 1.9(1), yet FFR is currently used in <10% of cases (2). Angiography-based virtual (v) FFR solutions permit less invasive physiological assessment and lend themselves to virtual coronary intervention (VCI) (Figure 1 ). VCI has been shown to predict the response to PCI with a high degree of accuracy(3). In this study, we sought to determine the potential impact of vFFR and VCI on real world stenting. Methods: Patients who had undergone PCI without FFR guidance were identified from the Sheffield archive. A 3D reconstruction of the diseased artery was generated from the angiogram. Baseline vFFR was calculated using computational fluid dynamics (CFD) analysis(4). If vFFR was <0.80, VCI was performed(3). Three PCI strategies were modelled. First, the actual PCI procedure was replicated. Second, the FFRmax was determined; the minimal amount of stenting to achieve the best possible FFR(5). Third, the optimal strategy was determined; the minimal amount of stenting to achieve a post VCI FFR >0.90 (6). For each strategy, the total number and length of stent per patient was determined and compared to the actual procedure, which was conducted in the normal way, guided by the angiogram alone. Results: Forty-three patients (56Abstract : Introduction: Using fractional flow reserve (FFR) to guide percutaneous coronary intervention (PCI) improves outcomes and reduces costs. In FAME, FFR guidance reduced the total length of stent per patient from 52mm to 38mm and the number from 2.7 to 1.9(1), yet FFR is currently used in <10% of cases (2). Angiography-based virtual (v) FFR solutions permit less invasive physiological assessment and lend themselves to virtual coronary intervention (VCI) (Figure 1 ). VCI has been shown to predict the response to PCI with a high degree of accuracy(3). In this study, we sought to determine the potential impact of vFFR and VCI on real world stenting. Methods: Patients who had undergone PCI without FFR guidance were identified from the Sheffield archive. A 3D reconstruction of the diseased artery was generated from the angiogram. Baseline vFFR was calculated using computational fluid dynamics (CFD) analysis(4). If vFFR was <0.80, VCI was performed(3). Three PCI strategies were modelled. First, the actual PCI procedure was replicated. Second, the FFRmax was determined; the minimal amount of stenting to achieve the best possible FFR(5). Third, the optimal strategy was determined; the minimal amount of stenting to achieve a post VCI FFR >0.90 (6). For each strategy, the total number and length of stent per patient was determined and compared to the actual procedure, which was conducted in the normal way, guided by the angiogram alone. Results: Forty-three patients (56 vessels) were studied. Mean vFFR pre-PCI was 0.74±0.16. Twenty-four (43%) vessels had a baseline FFR >0.80. For the actual procedure, mean post-PCI vFFR was 0.90±0.09. The number of stents per patient was 1.4±0.6. Total stent length per patient was 29±15mm. Mean FFRmax was 0.92±0.07. FFRmax was 0.02±0.03 higher than the corresponding measured post-PCI FFR. When the virtual procedure was planned to achieve FFRmax, the number of stents per patient was 0.9±1.0 (p=0.003). Total stent length per patient was 22±27mm (p=0.04). When the virtual procedure was planned to achieve a post VCI FFR >0.90, the number of stents per patient was 0.93±1.02 (p=0.002). Total stent length per patient was 20±25mm (p=0.01). Conclusion: In our cohort, 43% of vessels had a vFFR >0.80 suggesting PCI could have been avoided. Using vFFR and VCI to plan PCI led to a significant reduction in the total number and length of stents recommended per patient. Further work on a larger cohort is required to determine if these findings would translate to improved clinical outcomes. Figure 1: The 3D reconstruction of the artery is displayed and the operator marks the location where they wish to deploy a stent identified by the red and the blue markers (A). The operator can adjust the radius of the desired virtual stent in the box labelled 'stent size'. The length can be altered by moving the position of the red and blue dots. In the example shown, a 3.0mmx20mm virtual stent has been inserted. The virtually stented artery is shown overlaying the original vessel in panel B. Reproduced from JACC: Cardiovascular Imaging(3) under creative commons license CC BY 4.0 Conflict of Interest: None … (more)
- Is Part Of:
- Heart. Volume 105(2019)Supplement 6
- Journal:
- Heart
- Issue:
- Volume 105(2019)Supplement 6
- Issue Display:
- Volume 105, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 105
- Issue:
- 6
- Issue Sort Value:
- 2019-0105-0006-0000
- Page Start:
- A45
- Page End:
- A45
- Publication Date:
- 2019-05
- Subjects:
- Computational modeling -- Percutaneous coronary intervention -- Fractional flow reserve
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2019-BCS.51 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19674.xml