The effect of steep Trendelenburg positioning on intraocular pressure and visual function during robotic-assisted radical prostatectomy. Issue 3 (24th September 2013)
- Record Type:
- Journal Article
- Title:
- The effect of steep Trendelenburg positioning on intraocular pressure and visual function during robotic-assisted radical prostatectomy. Issue 3 (24th September 2013)
- Main Title:
- The effect of steep Trendelenburg positioning on intraocular pressure and visual function during robotic-assisted radical prostatectomy
- Authors:
- Hoshikawa, Yuko
Tsutsumi, Noriko
Ohkoshi, Kisiko
Serizawa, Satoshi
Hamada, Masafumi
Inagaki, Keiji
Tsuzuki, Kentaro
Koshimizu, Junko
Echizen, Nariaki
Fujitani, Syuko
Takahashi, Osamu
Deshpande, Gautam A - Abstract:
- Abstract : Background: To evaluate intraocular pressure (IOP) changes in patients undergoing robotic-assisted radical prostatectomy and to evaluate complications from increased IOP. Methods: Thirty-one eyes scheduled for robotic prostatectomy were included. Perioperative IOP measurements were performed as follows: prior to induction of anaesthesia while supine and awake (T1); immediately post-induction while supine (T2); every hour from 0 to 5 h while anaesthetised in a steep Trendelenburg position (T3–T8); prior to awakening while supine (T9); and 30 min after awakening while supine (T10). A complete ophthalmic examination including visual acuity and retinal nerve fibre layer thickness (RNFL) was performed at enrolment and 1 month postoperatively. Results: Average IOP (mm Hg) for each time point was as follows: T1=18.0, T2=9.8, T3=18.9, T4=21.6, T5=22.5, T6=22.3, T7=24.2, T8=24.0, T9=15.7 and T10=17.9. The proportion of eyes with intraoperative IOP ≧30 mm Hg were as follows: T3=0%, T4=3.23%, T5=9.68%, T6=6.45%, T7=22.22%, and T8=25%. Maximum IOP was 36 mm Hg. Mean visual acuity (logarithm of the minimal angle of resolution) and RNFL showed no statistically significant difference before and after operation and no other ocular complications were found at final examination. Conclusions: While IOP increased in a time-dependent fashion in anesthaetised patients undergoing robotic-assisted radical prostatectomy in a steep Trendelenburg position, visual function showed noAbstract : Background: To evaluate intraocular pressure (IOP) changes in patients undergoing robotic-assisted radical prostatectomy and to evaluate complications from increased IOP. Methods: Thirty-one eyes scheduled for robotic prostatectomy were included. Perioperative IOP measurements were performed as follows: prior to induction of anaesthesia while supine and awake (T1); immediately post-induction while supine (T2); every hour from 0 to 5 h while anaesthetised in a steep Trendelenburg position (T3–T8); prior to awakening while supine (T9); and 30 min after awakening while supine (T10). A complete ophthalmic examination including visual acuity and retinal nerve fibre layer thickness (RNFL) was performed at enrolment and 1 month postoperatively. Results: Average IOP (mm Hg) for each time point was as follows: T1=18.0, T2=9.8, T3=18.9, T4=21.6, T5=22.5, T6=22.3, T7=24.2, T8=24.0, T9=15.7 and T10=17.9. The proportion of eyes with intraoperative IOP ≧30 mm Hg were as follows: T3=0%, T4=3.23%, T5=9.68%, T6=6.45%, T7=22.22%, and T8=25%. Maximum IOP was 36 mm Hg. Mean visual acuity (logarithm of the minimal angle of resolution) and RNFL showed no statistically significant difference before and after operation and no other ocular complications were found at final examination. Conclusions: While IOP increased in a time-dependent fashion in anesthaetised patients undergoing robotic-assisted radical prostatectomy in a steep Trendelenburg position, visual function showed no significant change postoperatively and no complications were seen. Steep Trendelenburg positioning during time-limited procedures appears to pose little or no risk from IOP increases in patients without pre-existing ocular disease. … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 98:Issue 3(2014)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 98:Issue 3(2014)
- Issue Display:
- Volume 98, Issue 3 (2014)
- Year:
- 2014
- Volume:
- 98
- Issue:
- 3
- Issue Sort Value:
- 2014-0098-0003-0000
- Page Start:
- 305
- Page End:
- 308
- Publication Date:
- 2013-09-24
- Subjects:
- Intraocular Pressure -- Glaucoma
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2013-303536 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19634.xml