Change in corneal microstructure with rigid gas permeable contact lens use following collagen cross-linking: an in vivo confocal microscopy study. Issue 4 (24th December 2013)
- Record Type:
- Journal Article
- Title:
- Change in corneal microstructure with rigid gas permeable contact lens use following collagen cross-linking: an in vivo confocal microscopy study. Issue 4 (24th December 2013)
- Main Title:
- Change in corneal microstructure with rigid gas permeable contact lens use following collagen cross-linking: an in vivo confocal microscopy study
- Authors:
- Sehra, Sri V
Titiyal, Jeewan S
Sharma, Namrata
Tandon, Radhika
Sinha, Rajesh - Abstract:
- Abstract : Aim: To study corneal microstructural changes with use of rigid gas permeable contact lenses (CLs) in keratoconus patients following collagen cross-linking (CXL). Methods: In a prospective, non-randomised, comparative case series, keratoconus patients with documented progression were offered CXL (365 nm, 3 mW/cm 2, 30 min with 0.1% riboflavin). Patients who refused CXL were fitted with CL and followed up for 6 months (keratoconus (KL)-CL; 25 eyes). Patients who underwent CXL were either fitted with CL 3 months after the procedure (CXL-CL; 26 eyes) or followed up with only spectacle correction (CXL-SL; 21 eyes). Outcome measures of over-refraction and corneal microstructure (confocal microscopy) were evaluated at time of CXL and 1, 2, 3, 4, 6 and 9 months after CXL. Results: There was a myopic shift in over-refraction by 0.37 D in CXL-CL (p=0.00), and 16/26 eyes required prescription of spectacles over CL to provide optimum vision; change in over-refraction was not seen in KC-CL. Patients using CL (CXL-CL and KC-CL) showed evidence of epithelial cell stress with increase in the superficial epithelial cell size and decrease in basal epithelial cell density. They also had a decrease in corneal sub-basal nerve plexus (CSNP) density and branching. Patients using spectacles after CXL showed regeneration of the sub-basal nerve plexus. Stromal keratocyte regeneration was unaffected with CL use. Conclusions: CL use after CXL is associated with a delay in the regenerationAbstract : Aim: To study corneal microstructural changes with use of rigid gas permeable contact lenses (CLs) in keratoconus patients following collagen cross-linking (CXL). Methods: In a prospective, non-randomised, comparative case series, keratoconus patients with documented progression were offered CXL (365 nm, 3 mW/cm 2, 30 min with 0.1% riboflavin). Patients who refused CXL were fitted with CL and followed up for 6 months (keratoconus (KL)-CL; 25 eyes). Patients who underwent CXL were either fitted with CL 3 months after the procedure (CXL-CL; 26 eyes) or followed up with only spectacle correction (CXL-SL; 21 eyes). Outcome measures of over-refraction and corneal microstructure (confocal microscopy) were evaluated at time of CXL and 1, 2, 3, 4, 6 and 9 months after CXL. Results: There was a myopic shift in over-refraction by 0.37 D in CXL-CL (p=0.00), and 16/26 eyes required prescription of spectacles over CL to provide optimum vision; change in over-refraction was not seen in KC-CL. Patients using CL (CXL-CL and KC-CL) showed evidence of epithelial cell stress with increase in the superficial epithelial cell size and decrease in basal epithelial cell density. They also had a decrease in corneal sub-basal nerve plexus (CSNP) density and branching. Patients using spectacles after CXL showed regeneration of the sub-basal nerve plexus. Stromal keratocyte regeneration was unaffected with CL use. Conclusions: CL use after CXL is associated with a delay in the regeneration of the CSNP and epithelial cell stress. … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 98:Issue 4(2014)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 98:Issue 4(2014)
- Issue Display:
- Volume 98, Issue 4 (2014)
- Year:
- 2014
- Volume:
- 98
- Issue:
- 4
- Issue Sort Value:
- 2014-0098-0004-0000
- Page Start:
- 442
- Page End:
- 447
- Publication Date:
- 2013-12-24
- Subjects:
- Cornea -- Contact lens
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2013-303934 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19629.xml