Application of multi-component fluid model in studies of the origin of skin burns during electrosurgical procedures. Issue 13 (3rd October 2021)
- Record Type:
- Journal Article
- Title:
- Application of multi-component fluid model in studies of the origin of skin burns during electrosurgical procedures. Issue 13 (3rd October 2021)
- Main Title:
- Application of multi-component fluid model in studies of the origin of skin burns during electrosurgical procedures
- Authors:
- Radmilović-Radjenović, Marija
Sabo, Martin
Radjenović, Branislav - Abstract:
- Abstract: This paper reports on safety challenges regarding spark created when the applied electric field exceeds the dielectric breakdown strength as a source of complication during electrosurgery. Despite the unquestionable benefits of electrosurgery, such as minimal chances of infection and fast recovery time, the interaction of the electrosurgical tool with the tissue may result in tissue damage and force feedback to the tool. Some risks of complications often depend on a surgeon's knowledge of instruments and safety aspects of technical equipment that can be eliminated by clarifying the causation and conditions of their development. Current trends in electrosurgery include computational algorithms and methods to control the effect of delivered energy to the patient. For this study, calculations were performed by using the COMSOL simulation package based on a multi-component plasma fluid model. The emphasis is put on conditions that lead to the breakdown of the dielectric medium. It was found that breakdown occurs most easily when both electrodes are cylindrical. For configurations with one or two spherical electrodes, breakdown voltages are higher up to 25% and 48%, respectively. With decreasing the cathode radius, the breakdown voltage may decrease even to 41%. On the other hand, the temperature increase lowers the breakdown voltage. Also, electrical asymmetries appear to be a response to the non-symmetry of the electric field between the electrodes causing differencesAbstract: This paper reports on safety challenges regarding spark created when the applied electric field exceeds the dielectric breakdown strength as a source of complication during electrosurgery. Despite the unquestionable benefits of electrosurgery, such as minimal chances of infection and fast recovery time, the interaction of the electrosurgical tool with the tissue may result in tissue damage and force feedback to the tool. Some risks of complications often depend on a surgeon's knowledge of instruments and safety aspects of technical equipment that can be eliminated by clarifying the causation and conditions of their development. Current trends in electrosurgery include computational algorithms and methods to control the effect of delivered energy to the patient. For this study, calculations were performed by using the COMSOL simulation package based on a multi-component plasma fluid model. The emphasis is put on conditions that lead to the breakdown of the dielectric medium. It was found that breakdown occurs most easily when both electrodes are cylindrical. For configurations with one or two spherical electrodes, breakdown voltages are higher up to 25% and 48%, respectively. With decreasing the cathode radius, the breakdown voltage may decrease even to 41%. On the other hand, the temperature increase lowers the breakdown voltage. Also, electrical asymmetries appear to be a response to the non-symmetry of the electric field between the electrodes causing differences in the breakdown voltage between 36% and 70%. The results presented here could be very useful for the design of surgical devices to prevent potential complications of electrosurgical procedures. … (more)
- Is Part Of:
- Computer methods in biomechanics and biomedical engineering. Volume 24:Issue 13(2021)
- Journal:
- Computer methods in biomechanics and biomedical engineering
- Issue:
- Volume 24:Issue 13(2021)
- Issue Display:
- Volume 24, Issue 13 (2021)
- Year:
- 2021
- Volume:
- 24
- Issue:
- 13
- Issue Sort Value:
- 2021-0024-0013-0000
- Page Start:
- 1409
- Page End:
- 1418
- Publication Date:
- 2021-10-03
- Subjects:
- Burns -- electrosurgery -- breakdown -- spark -- COMSOL -- multi-component
Biomechanics -- Data processing -- Periodicals
Biomedical engineering -- Periodicals
Biomechanics -- Periodicals
Biomedical Engineering -- methods -- Periodicals
Computing Methodologies -- Periodicals
612.7 - Journal URLs:
- http://www.tandfonline.com/toc/gcmb20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/10255842.2021.1890721 ↗
- Languages:
- English
- ISSNs:
- 1025-5842
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.100250
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19622.xml