Anterior nasal versus nasal mid-turbinate sampling for a SARS-CoV-2 antigen-detecting rapid test: does localisation or professional collection matter?. Issue 12 (2nd December 2021)
- Record Type:
- Journal Article
- Title:
- Anterior nasal versus nasal mid-turbinate sampling for a SARS-CoV-2 antigen-detecting rapid test: does localisation or professional collection matter?. Issue 12 (2nd December 2021)
- Main Title:
- Anterior nasal versus nasal mid-turbinate sampling for a SARS-CoV-2 antigen-detecting rapid test: does localisation or professional collection matter?
- Authors:
- Nikolai, Olga
Rohardt, Chiara
Tobian, Frank
Junge, Andrea
Corman, Victor M.
Jones, Terry C.
Gaeddert, Mary
Lainati, Federica
Sacks, Jilian A.
Seybold, Joachim
Mockenhaupt, Frank P.
Denkinger, Claudia M.
Lindner, Andreas K. - Abstract:
- Abstract: Introduction: Most SARS-CoV-2 antigen-detecting rapid diagnostic tests require nasopharyngeal sampling, which is frequently perceived as uncomfortable and requires healthcare professionals, thus limiting scale-up. Nasal sampling could enable self-sampling and increase acceptability. The term nasal sampling is often not used uniformly and sampling protocols differ. Methods: This manufacturer-independent, prospective diagnostic accuracy study, compared professional anterior nasal and nasal mid-turbinate sampling for a WHO-listed SARS-CoV-2 antigen-detecting rapid diagnostic test. The second group of participants collected a nasal mid-turbinate sample themselves and underwent a professional nasopharyngeal swab for comparison. The reference standard was real-time polymerase chain reaction (RT-PCR) using combined oro-/nasopharyngeal sampling. Individuals with high suspicion of SARS-CoV-2 infection were tested. Sensitivity, specificity, and percent agreement were calculated. Self-sampling was observed without intervention. Feasibility was evaluated by observer and participant questionnaires. Results: Among 132 symptomatic adults, both professional anterior nasal and nasal mid-turbinate sampling yielded a sensitivity of 86.1% (31/36 RT-PCR positives detected; 95%CI: 71.3–93.9) and a specificity of 100.0% (95%CI: 95.7–100). The positive percent agreement was 100% (95%CI: 89.0–100). Among 96 additional adults, self nasal mid-turbinate and professional nasopharyngealAbstract: Introduction: Most SARS-CoV-2 antigen-detecting rapid diagnostic tests require nasopharyngeal sampling, which is frequently perceived as uncomfortable and requires healthcare professionals, thus limiting scale-up. Nasal sampling could enable self-sampling and increase acceptability. The term nasal sampling is often not used uniformly and sampling protocols differ. Methods: This manufacturer-independent, prospective diagnostic accuracy study, compared professional anterior nasal and nasal mid-turbinate sampling for a WHO-listed SARS-CoV-2 antigen-detecting rapid diagnostic test. The second group of participants collected a nasal mid-turbinate sample themselves and underwent a professional nasopharyngeal swab for comparison. The reference standard was real-time polymerase chain reaction (RT-PCR) using combined oro-/nasopharyngeal sampling. Individuals with high suspicion of SARS-CoV-2 infection were tested. Sensitivity, specificity, and percent agreement were calculated. Self-sampling was observed without intervention. Feasibility was evaluated by observer and participant questionnaires. Results: Among 132 symptomatic adults, both professional anterior nasal and nasal mid-turbinate sampling yielded a sensitivity of 86.1% (31/36 RT-PCR positives detected; 95%CI: 71.3–93.9) and a specificity of 100.0% (95%CI: 95.7–100). The positive percent agreement was 100% (95%CI: 89.0–100). Among 96 additional adults, self nasal mid-turbinate and professional nasopharyngeal sampling yielded an identical sensitivity of 91.2% (31/34; 95%CI 77.0–97.0). Specificity was 98.4% (95%CI: 91.4–99.9) with nasal mid-turbinate and 100.0% (95%CI: 94.2–100) with nasopharyngeal sampling. The positive percent agreement was 96.8% (95%CI: 83.8–99.8). Most participants (85.3%) considered self-sampling as easy to perform. Conclusion: Professional anterior nasal and nasal mid-turbinate sampling are of equivalent accuracy for an antigen-detecting rapid diagnostic test in ambulatory symptomatic adults. Participants were able to reliably perform nasal mid-turbinate sampling themselves, following written and illustrated instructions. Nasal self-sampling will facilitate scaling of SARS-CoV-2 antigen testing. … (more)
- Is Part Of:
- Infectious diseases. Volume 53:Issue 12(2021)
- Journal:
- Infectious diseases
- Issue:
- Volume 53:Issue 12(2021)
- Issue Display:
- Volume 53, Issue 12 (2021)
- Year:
- 2021
- Volume:
- 53
- Issue:
- 12
- Issue Sort Value:
- 2021-0053-0012-0000
- Page Start:
- 947
- Page End:
- 952
- Publication Date:
- 2021-12-02
- Subjects:
- COVID-19 -- SARS-CoV-2 -- self-sampling -- nasal-sampling -- anterior nasal -- nasal mid-turbinate -- antigen-detecting rapid test
Communicable diseases -- Periodicals
Communicable Diseases -- Periodicals
Communicable diseases
Periodicals
616.9 - Journal URLs:
- http://www.tandfonline.com/loi/infd19#.VksX11Inzcs ↗
http://informahealthcare.com/loi/inf ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/23744235.2021.1969426 ↗
- Languages:
- English
- ISSNs:
- 2374-4235
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19637.xml