Five-year changes in anterior segment parameters in an older population in urban southern China: the Liwan Eye Study. Issue 4 (4th September 2019)
- Record Type:
- Journal Article
- Title:
- Five-year changes in anterior segment parameters in an older population in urban southern China: the Liwan Eye Study. Issue 4 (4th September 2019)
- Main Title:
- Five-year changes in anterior segment parameters in an older population in urban southern China: the Liwan Eye Study
- Authors:
- Jiang, Yu
Wang, Decai
Wang, Wei
Chen, Feng
Wang, Lanhua
Scheetz, Jane
Huang, Wenyong
Huang, Shengsong
He, Mingguang - Abstract:
- Abstract : Purpose: To investigate the 5-year changes in static and dynamic anterior segment optical coherence tomography (AS-OCT) parameters and their predictors. Methods: This was a prospective, population-based cohort study of people aged 50 years and older residing in the Liwan District, Guangzhou, China. Standardised AS-OCT scans were performed in November 2008 and November 2013 under dark and light conditions. Customised software was used to analyse horizontal AS-OCT images. Parameters in dark and measurements of light-to-dark changes were used for analyses. Results: A total of 186 (71.8%) subjects underwent AS-OCT twice, 5 years apart and were included for analyses. The mean age in 2008 was 64.7±7.0 years, and 60.2% were women. The anterior chamber width (ACW) decreased from 11.74±0.44 mm in 2008 to 11.60±0.37 mm in 2013 (p=0.001). There was a trend towards a decrease in dynamic capacity (light-to-dark changes) in the anterior segment, with decreased iris thickness at 750 µm (ΔIT750), ΔACW, Δ anterior chamber area (ACA) and Δ pupil diameter at 5 years (all p<0.05). After adjusting for age and sex, the following baseline parameters were associated with a greater decrease rate in trabecular iris space area at 500 µm (TISA500) at 5 years: TISA500, IT750 and ACA in dark (p<0.001 for all). Conclusions: Anterior chamber angle width decreased and the amount of light-to-dark changes declined during 5-year follow-up. Subjects with greater height, wider angle width and thickerAbstract : Purpose: To investigate the 5-year changes in static and dynamic anterior segment optical coherence tomography (AS-OCT) parameters and their predictors. Methods: This was a prospective, population-based cohort study of people aged 50 years and older residing in the Liwan District, Guangzhou, China. Standardised AS-OCT scans were performed in November 2008 and November 2013 under dark and light conditions. Customised software was used to analyse horizontal AS-OCT images. Parameters in dark and measurements of light-to-dark changes were used for analyses. Results: A total of 186 (71.8%) subjects underwent AS-OCT twice, 5 years apart and were included for analyses. The mean age in 2008 was 64.7±7.0 years, and 60.2% were women. The anterior chamber width (ACW) decreased from 11.74±0.44 mm in 2008 to 11.60±0.37 mm in 2013 (p=0.001). There was a trend towards a decrease in dynamic capacity (light-to-dark changes) in the anterior segment, with decreased iris thickness at 750 µm (ΔIT750), ΔACW, Δ anterior chamber area (ACA) and Δ pupil diameter at 5 years (all p<0.05). After adjusting for age and sex, the following baseline parameters were associated with a greater decrease rate in trabecular iris space area at 500 µm (TISA500) at 5 years: TISA500, IT750 and ACA in dark (p<0.001 for all). Conclusions: Anterior chamber angle width decreased and the amount of light-to-dark changes declined during 5-year follow-up. Subjects with greater height, wider angle width and thicker iris at baseline have greater angle narrowing at follow-up. … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 104:Issue 4(2020)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 104:Issue 4(2020)
- Issue Display:
- Volume 104, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 104
- Issue:
- 4
- Issue Sort Value:
- 2020-0104-0004-0000
- Page Start:
- 582
- Page End:
- 587
- Publication Date:
- 2019-09-04
- Subjects:
- population-based study -- anterior segment optic coherence tomography -- dynamics -- angle closure
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2019-313827 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19636.xml