Development and validation of a machine learning, smartphone-based tonometer. Issue 10 (23rd December 2019)
- Record Type:
- Journal Article
- Title:
- Development and validation of a machine learning, smartphone-based tonometer. Issue 10 (23rd December 2019)
- Main Title:
- Development and validation of a machine learning, smartphone-based tonometer
- Authors:
- Wu, Yue
Luttrell, Ian
Feng, Shu
Chen, Philip P
Spaide, Ted
Lee, Aaron Y
Wen, Joanne C - Abstract:
- Abstract : Background/Aims: To compare intraocular pressure (IOP) measurements using a prototype smartphone tonometer with other tonometers used in clinical practice. Methods: Patients from an academic glaucoma practice were recruited. The smartphone tonometer uses fixed force applanation and in conjunction with a machine-learning computer algorithm is able to calculate the IOP. IOP was also measured using Goldmann applanation tonometry (GAT) in all subjects. A subset of patients were also measured using ICare, pneumotonometry (upright and supine positions) and Tono-Pen (upright and supine positions) and the results were compared. Results: 92 eyes of 81 subjects were successfully measured. The mean difference (in mm Hg) for IOP measurements of the smartphone tonometer versus other devices was +0.24 mm Hg for GAT, −1.39 mm Hg for ICare, −3.71 mm Hg for pneumotonometry and −1.30 mm Hg for Tono-Pen. The 95% limits of agreement for the smartphone tonometer versus other devices was −4.35 to 4.83 mm Hg for GAT, −6.48 to 3.70 mm Hg for ICare, −7.66 to −0.15 mm Hg for pneumotonometry and −5.72 to 3.12 mm Hg for Tono-Pen. Overall, the smartphone tonometer results correlated best with GAT (R 2 =0.67, p<0.001). Of the 92 videos, 90 (97.8%) were within ±5 mm Hg of GAT and 58 (63.0%) were within ±2 mm Hg of GAT. Conclusions: Preliminary IOP measurements using a prototype smartphone-based tonometer was grossly equivalent to the reference standard.
- Is Part Of:
- British journal of ophthalmology. Volume 104:Issue 10(2020)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 104:Issue 10(2020)
- Issue Display:
- Volume 104, Issue 10 (2020)
- Year:
- 2020
- Volume:
- 104
- Issue:
- 10
- Issue Sort Value:
- 2020-0104-0010-0000
- Page Start:
- 1394
- Page End:
- 1398
- Publication Date:
- 2019-12-23
- Subjects:
- intraocular pressure
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2019-315446 ↗