Covalent organic framework-LZU1@PEI@Fe3O4-based magnetic dispersive micro-solid phase extraction of tetracyclines from environmental water prior to HPLC analysis. Issue 37 (3rd September 2021)
- Record Type:
- Journal Article
- Title:
- Covalent organic framework-LZU1@PEI@Fe3O4-based magnetic dispersive micro-solid phase extraction of tetracyclines from environmental water prior to HPLC analysis. Issue 37 (3rd September 2021)
- Main Title:
- Covalent organic framework-LZU1@PEI@Fe3O4-based magnetic dispersive micro-solid phase extraction of tetracyclines from environmental water prior to HPLC analysis
- Authors:
- Zhang, Ying
Ning, Yuhan
Liao, Wanliang
Wang, Weiping
Wang, Ai-Jun - Abstract:
- Abstract : Schematic of the m-μ-dSPE-HPLC strategy for the extraction and detection of TCs. Abstract : In this work, COF-LZU1@PEI@Fe3 O4 was synthesized by immobilization of COF-LZU1 onto the surface of polyethyleneimine-functionalized Fe3 O4 nanoparticles (PEI@Fe3 O4 ) and employed as an adsorbent for magnetic dispersive micro-solid phase extraction of tetracyclines (TCs). COF-LZU1@PEI@Fe3 O4 was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, X-ray diffraction and nitrogen adsorption–desorption isotherms analysis. The optimal extraction and desorption conditions were as follows: 15.00 mL sample solution (pH 7.0) extracted with 5.0 mg of adsorbent for 30 min at 30 °C, and then desorbed with 1.50 mL methanol/acetonitrile/0.02 mol L −1 oxalic acid solution (v/v, 1 : 2 : 7). Good linearities were obtained between the peak area and TC concentration ranging from 5–500 μg L −1 with correlation coefficients ( R 2 ) higher than 0.9992 and limits of detection lower than 0.51 μg L −1 . The relative standard deviations (RSDs) of intra-day and inter-day were less than 5.7% and 7.4%, respectively. The developed method was successfully applied to the determination of TCs in environmental water samples with recoveries in the range of 87.0–113.8% and RSDs less than 5.1%, suggesting great potential of COF-LZU1@PEI@Fe3 O4 for efficient extraction and analysis of trace TCs in water samples.
- Is Part Of:
- Analytical methods. Volume 13:Issue 37(2021)
- Journal:
- Analytical methods
- Issue:
- Volume 13:Issue 37(2021)
- Issue Display:
- Volume 13, Issue 37 (2021)
- Year:
- 2021
- Volume:
- 13
- Issue:
- 37
- Issue Sort Value:
- 2021-0013-0037-0000
- Page Start:
- 4320
- Page End:
- 4327
- Publication Date:
- 2021-09-03
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d1ay00873k ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19634.xml