Characterization of occlusal splint materials: CAD-CAM versus conventional resins. (December 2021)
- Record Type:
- Journal Article
- Title:
- Characterization of occlusal splint materials: CAD-CAM versus conventional resins. (December 2021)
- Main Title:
- Characterization of occlusal splint materials: CAD-CAM versus conventional resins
- Authors:
- Gibreel, Mona
Perea-Lowery, Leila
Vallittu, Pekka K.
Lassila, Lippo - Abstract:
- Abstract: Aim: The aim of this in vitro study was to assess the mechanical properties of five commercially available subtractive computer-aided design and computer-aided manufacturing (CAD-CAM) milled splint materials, as well as to compare them with conventional heat-polymerized and autopolymerizing resins used in the construction of conventional splints. Material and methods: Five CAD-CAM milled (ProArt CAD Splint, Therapon Transpa, Temp Premium Flexible Transpa, Cast, and Aqua), one autopolymerizing (Palapress), and one heat-polymerized (Paladon 65) resin materials were evaluated. Flexural strength, E-modulus, Vickers hardness, fracture toughness, fracture work, water sorption, and water solubility were measured. Samples were evaluated after dry and water storage for 30 days at 37 °C. Data were collected and statistically analyzed. Results: Under both storage circumstances, the flexural strength values of Paladon 65, Therapon Transpa, Temp Premium Flexible Transpa, and Aqua were statistically non-significant ( P =0.055). The polycarbonate-based CAD-CAM material Temp Premium Flexible Transpa had the highest statistically significant values of the fracture toughness and fracture work ( P <0.001). Moreover, it exhibited the lowest percentages of water sorption and water solubility among the investigated materials ( P <0.001). All of the CAD-CAM materials exhibited dry elastic moduli greater than Palapress and lower than Paladon 65. One of the CAD-CAM materials, Cast, had theAbstract: Aim: The aim of this in vitro study was to assess the mechanical properties of five commercially available subtractive computer-aided design and computer-aided manufacturing (CAD-CAM) milled splint materials, as well as to compare them with conventional heat-polymerized and autopolymerizing resins used in the construction of conventional splints. Material and methods: Five CAD-CAM milled (ProArt CAD Splint, Therapon Transpa, Temp Premium Flexible Transpa, Cast, and Aqua), one autopolymerizing (Palapress), and one heat-polymerized (Paladon 65) resin materials were evaluated. Flexural strength, E-modulus, Vickers hardness, fracture toughness, fracture work, water sorption, and water solubility were measured. Samples were evaluated after dry and water storage for 30 days at 37 °C. Data were collected and statistically analyzed. Results: Under both storage circumstances, the flexural strength values of Paladon 65, Therapon Transpa, Temp Premium Flexible Transpa, and Aqua were statistically non-significant ( P =0.055). The polycarbonate-based CAD-CAM material Temp Premium Flexible Transpa had the highest statistically significant values of the fracture toughness and fracture work ( P <0.001). Moreover, it exhibited the lowest percentages of water sorption and water solubility among the investigated materials ( P <0.001). All of the CAD-CAM materials exhibited dry elastic moduli greater than Palapress and lower than Paladon 65. One of the CAD-CAM materials, Cast, had the highest dry Vickers hardness value, which was non-significant when compared to Therapon Transpa ( P =0.762). Conclusion: CAD-CAM polycarbonate-based splint materials exhibit higher fracture toughness and fracture work as well as lower water sorption and solubility than polymethyl methacrylate-based ones. The mechanical characteristics of the assessed CAD-CAM milled splint materials were not typically superior to those of the conventional heat-polymerized resin. However, some of them outperformed the autopolymerizing acrylic resin in terms of flexural strength, surface microhardness, water sorption, and water solubility. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 124(2021)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 124(2021)
- Issue Display:
- Volume 124, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 124
- Issue:
- 2021
- Issue Sort Value:
- 2021-0124-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-12
- Subjects:
- Splints -- Polymethyl methacrylate -- Flexural strength -- Modulus -- Toughness -- Water sorption
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2021.104813 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19622.xml