- An experimental study of the seismic behaviour of precast concrete shear walls with bolted-plate connections
- Authors:
- Pan, Guang-Bin
Cai, Jian
He, An
Chen, Qing-Jun
Zuo, Zhi-Liang
He, Bing-Quan
Tang, Xu-Lin
Wu, Hong-Wei - Abstract:
- Highlights: An innovative precast reinforced concrete shear wall with bolt-plate connection was proposed. Horizontal cyclic loading tests on the precast walls were conducted. The seismic performance of the precast walls was examined. Design methods for the precast shear walls were proposed. Abstract: The seismic resistance of an innovative precast reinforced concrete shear wall with vertical plates along its bottom edge to be bolted to plates protruding from the foundation was tested in reduced-scale model in the laboratory. Five precast shear walls with different wall heights and axial loads, as well as one reference cast-in-place shear wall, were tested. Horizontal cyclic loading was applied to examine the seismic performance of the specimens. The failure modes of the shear walls are discussed, along with their hysteretic behaviour, stiffness degradation, energy dissipation capacity, slip at the bolted connections, and strains in the reinforcement and in the connecting plates. The test results show that the bolted-plate connections can effectively transfer vertical and shear forces, as well as bending moments, to the foundation beam without any slip along the connection. The precast specimens exhibited approximately the same seismic behaviour as the cast-in-place one. In general, the failure mode shifts from compression-bending to shear-compression at smaller heights of the walls, with an increase in the bearing capacity, but a reduction in wall deformability and theHighlights: An innovative precast reinforced concrete shear wall with bolt-plate connection was proposed. Horizontal cyclic loading tests on the precast walls were conducted. The seismic performance of the precast walls was examined. Design methods for the precast shear walls were proposed. Abstract: The seismic resistance of an innovative precast reinforced concrete shear wall with vertical plates along its bottom edge to be bolted to plates protruding from the foundation was tested in reduced-scale model in the laboratory. Five precast shear walls with different wall heights and axial loads, as well as one reference cast-in-place shear wall, were tested. Horizontal cyclic loading was applied to examine the seismic performance of the specimens. The failure modes of the shear walls are discussed, along with their hysteretic behaviour, stiffness degradation, energy dissipation capacity, slip at the bolted connections, and strains in the reinforcement and in the connecting plates. The test results show that the bolted-plate connections can effectively transfer vertical and shear forces, as well as bending moments, to the foundation beam without any slip along the connection. The precast specimens exhibited approximately the same seismic behaviour as the cast-in-place one. In general, the failure mode shifts from compression-bending to shear-compression at smaller heights of the walls, with an increase in the bearing capacity, but a reduction in wall deformability and the energy-dissipation capability. At smaller values of the axial loads, the bearing capacity decreases but the deformability increases. The existing Chinese design code for normal reinforced concrete shear walls gives safe design limits also for the precast walls with bolted-plate connections. … (more)
- Is Part Of:
- Engineering structures. Volume 248(2021)
- Journal:
- Engineering structures
- Issue:
- Volume 248(2021)
- Issue Display:
- Volume 248, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 248
- Issue:
- 2021
- Issue Sort Value:
- 2021-0248-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-12-01
- Subjects:
- Precast shear walls -- Reinforced concrete -- Bolted-plate connections -- Seismic performance -- Horizontal cyclic loading -- Hysteresis loops -- Stiffness degradation -- Ductility -- Shear deformation -- Design codes
Structural engineering -- Periodicals
Structural analysis (Engineering) -- Periodicals
Construction, Technique de la -- Périodiques
Génie parasismique -- Périodiques
Pression du vent -- Périodiques
Earthquake engineering
Structural engineering
Wind-pressure
Periodicals
624.105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01410296 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engstruct.2021.113203 ↗
- Languages:
- English
- ISSNs:
- 0141-0296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3770.032000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19638.xml