Comparison of sodium alginate-based and sodium hyaluronate-based submucosal injection materials based on rheological analysis. (December 2021)
- Record Type:
- Journal Article
- Title:
- Comparison of sodium alginate-based and sodium hyaluronate-based submucosal injection materials based on rheological analysis. (December 2021)
- Main Title:
- Comparison of sodium alginate-based and sodium hyaluronate-based submucosal injection materials based on rheological analysis
- Authors:
- Hirose, Ryohei
Watanabe, Naoto
Naito, Yuji
Hashimoto, Hikaru
Sugino, Satoshi
Yoshida, Takuma
Bandou, Risa
Daidoji, Tomo
Inoue, Ken
Dohi, Osamu
Yoshida, Naohisa
Nakaya, Takaaki
Itoh, Yoshito - Abstract:
- Abstract: As a viscous high-performance submucosal injection material (SIM) used in endoscopic submucosal dissection (ESD), sodium alginate-based SIM (SA-SIM) was recently introduced as high-performance SIM equivalent to sodium hyaluronate-based SIM (HA-SIM) in Japan. However, a comprehensive, detailed comparison of SA and HA is yet to be performed. In this study, we precisely measured the viscoelastic properties, submucosal elevation height (SEH), and injection pressure (IP). Furthermore, we compared the outcomes of ESD using an ex vivo ESD model. There was no significant difference in SEHs between HA-SIM and SA-SIM at all post-injection times, and the IP of the SA-SIM injection was significantly higher than that of the HA-SIM injection in all conditions (P < 0.0001). The viscosity at high shear rates of SA-SIM was higher than that of HA-SIM; this result was consistent with SEH/IP measurement results. No significant difference was observed in ESD procedure time and total volume of injected SIM between HA-SIM and SA-SIM (18.1 ± 6.7 and 17.8 ± 6.0 min, P = 0.8987; 13.3 ± 5.3 and 11.6 ± 5.9 ml, P = 0.4658, respectively). Although SA-SIM was slightly more difficult to inject than HA-SIM, there was no significant difference in performance between the materials. Thus, this basic study demonstrated that SA-SIM can be used for endoscopic treatment as well as HA-SIM, and supported previous clinical research data. Highlights: The viscosity of SA-SIM at high shear rates was higherAbstract: As a viscous high-performance submucosal injection material (SIM) used in endoscopic submucosal dissection (ESD), sodium alginate-based SIM (SA-SIM) was recently introduced as high-performance SIM equivalent to sodium hyaluronate-based SIM (HA-SIM) in Japan. However, a comprehensive, detailed comparison of SA and HA is yet to be performed. In this study, we precisely measured the viscoelastic properties, submucosal elevation height (SEH), and injection pressure (IP). Furthermore, we compared the outcomes of ESD using an ex vivo ESD model. There was no significant difference in SEHs between HA-SIM and SA-SIM at all post-injection times, and the IP of the SA-SIM injection was significantly higher than that of the HA-SIM injection in all conditions (P < 0.0001). The viscosity at high shear rates of SA-SIM was higher than that of HA-SIM; this result was consistent with SEH/IP measurement results. No significant difference was observed in ESD procedure time and total volume of injected SIM between HA-SIM and SA-SIM (18.1 ± 6.7 and 17.8 ± 6.0 min, P = 0.8987; 13.3 ± 5.3 and 11.6 ± 5.9 ml, P = 0.4658, respectively). Although SA-SIM was slightly more difficult to inject than HA-SIM, there was no significant difference in performance between the materials. Thus, this basic study demonstrated that SA-SIM can be used for endoscopic treatment as well as HA-SIM, and supported previous clinical research data. Highlights: The viscosity of SA-SIM at high shear rates was higher than that of HA-SIM. The IP of SA-SIM injection was significantly higher than that of HA-SIM injection. There was no significant difference in SEHs between HA-SIM and SA-SIM. No significant difference was observed in ESD outcomes between HA-SIM and SA-SIM. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 124(2021)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 124(2021)
- Issue Display:
- Volume 124, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 124
- Issue:
- 2021
- Issue Sort Value:
- 2021-0124-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-12
- Subjects:
- Endoscopic submucosal dissection -- Submucosal injection material -- Rheology -- Sodium hyaluronate -- Sodium alginate
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2021.104816 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19622.xml