Rapid antibiotic susceptibility testing using resazurin bulk modified screen-printed electrochemical sensing platforms. Issue 18 (9th August 2021)
- Record Type:
- Journal Article
- Title:
- Rapid antibiotic susceptibility testing using resazurin bulk modified screen-printed electrochemical sensing platforms. Issue 18 (9th August 2021)
- Main Title:
- Rapid antibiotic susceptibility testing using resazurin bulk modified screen-printed electrochemical sensing platforms
- Authors:
- Crane, Benjamin
Hughes, Jack P.
Rowley Neale, Samuel J.
Rashid, Mamun
Linton, Patricia E.
Banks, Craig E.
Shaw, Kirsty J. - Abstract:
- Abstract : Urinary tract infections (UTIs) are one of the most common types of bacterial infection. Abstract : Urinary tract infections (UTIs) are one of the most common types of bacterial infection. UTIs can be associated with multidrug resistant bacteria and current methods of determining an effective antibiotic for UTIs can take up to 48 hours, which increases the chances of a negative prognosis for the patient. In this paper we report for the first time, the fabrication of resazurin bulk modified screen-printed macroelectrodes (R-SPEs) demonstrating them to be effective platforms for the electrochemical detection of antibiotic susceptibility in complicated UTIs. Using differential pulse voltammetry (DPV), resazurin was able to be detected down to 15.6 μM. R-SPEs were utilised to conduct antibiotic susceptibility testing (AST) of E. coli (ATCC® 25922) to the antibiotic gentamicin sulphate using DPV to detect the relative concentrations of resazurin between antibiotic treated bacteria, and bacteria without antibiotic treatment. Using R-SPEs, antibiotic susceptibility was determined after a total elapsed time of 90 minutes including the inoculation of the artificial urine, preincubation and testing time. The use of electrochemistry as a phenotypic means of identifying an effective antibiotic to treat a complicated UTI offers a rapid and accurate alternative to culture based methods for AST with R-SPEs offering an inexpensive and simpler alternative to other AST methodsAbstract : Urinary tract infections (UTIs) are one of the most common types of bacterial infection. Abstract : Urinary tract infections (UTIs) are one of the most common types of bacterial infection. UTIs can be associated with multidrug resistant bacteria and current methods of determining an effective antibiotic for UTIs can take up to 48 hours, which increases the chances of a negative prognosis for the patient. In this paper we report for the first time, the fabrication of resazurin bulk modified screen-printed macroelectrodes (R-SPEs) demonstrating them to be effective platforms for the electrochemical detection of antibiotic susceptibility in complicated UTIs. Using differential pulse voltammetry (DPV), resazurin was able to be detected down to 15.6 μM. R-SPEs were utilised to conduct antibiotic susceptibility testing (AST) of E. coli (ATCC® 25922) to the antibiotic gentamicin sulphate using DPV to detect the relative concentrations of resazurin between antibiotic treated bacteria, and bacteria without antibiotic treatment. Using R-SPEs, antibiotic susceptibility was determined after a total elapsed time of 90 minutes including the inoculation of the artificial urine, preincubation and testing time. The use of electrochemistry as a phenotypic means of identifying an effective antibiotic to treat a complicated UTI offers a rapid and accurate alternative to culture based methods for AST with R-SPEs offering an inexpensive and simpler alternative to other AST methods utilising electrochemical based approaches. … (more)
- Is Part Of:
- Analyst. Volume 146:Issue 18(2021)
- Journal:
- Analyst
- Issue:
- Volume 146:Issue 18(2021)
- Issue Display:
- Volume 146, Issue 18 (2021)
- Year:
- 2021
- Volume:
- 146
- Issue:
- 18
- Issue Sort Value:
- 2021-0146-0018-0000
- Page Start:
- 5574
- Page End:
- 5583
- Publication Date:
- 2021-08-09
- Subjects:
- Chemistry, Analytic -- Periodicals
543 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/an?e=1#!issueid=an139020&type=current&issnprint=0003-2654 ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d1an00850a ↗
- Languages:
- English
- ISSNs:
- 0003-2654
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0893.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19628.xml