A comprehensive investigation of the microbial risk of secondary water supply systems in residential neighborhoods in a large city. (15th October 2021)
- Record Type:
- Journal Article
- Title:
- A comprehensive investigation of the microbial risk of secondary water supply systems in residential neighborhoods in a large city. (15th October 2021)
- Main Title:
- A comprehensive investigation of the microbial risk of secondary water supply systems in residential neighborhoods in a large city
- Authors:
- Hu, Dong
Hong, Huarong
Rong, Biao
Wei, Yating
Zeng, Jie
Zhu, Jun
Bai, Lijun
Guo, Feng
Yu, Xin - Abstract:
- Highlights: SWSSs were important reservoirs for opportunistic and enteric pathogens. SWSSs could promote the microbial regrowth and colonization of pathogens. Potential pathogenic Legionella had a higher detection frequency in local SWSSs. Water temperature and chlorine residuals drove the changes of microbiomes. Abstract: Secondary water supply systems (SWSSs) are characterized by long water stagnation and low levels of chlorine residuals, which may pose a high microbial risk to terminal users. In this study, the SWSSs of 12 residential neighborhoods in a metropolitan area of 5 million people in southeastern China were seasonally investigated to assess their microbial risks by determining more than 30 physicochemical and biological parameters. Although the microbiological quality of SWSS water met the requirements of the standards for drinking water quality of China, it did deteriorate in various aspects. The heterotrophic plate counts with R2A media were high (> 100 CFU/mL) in some SWSS tank and tap water samples. Propidium monoazide (PMA)-qPCR revealed a one magnitude higher abundance of viable bacteria in the tank and tap water samples (average 10 3.63±1.10 and 10 3.65±1.25 gene copies/mL, respectively) compared with the input water samples, and Enterococcus, Acanthamoeba, and Hartmannella vermiformis were only detected in the tanks. In particular, the high detection frequency of Legionella in 35% tank and 21% tap water samples suggested it is a supplementary microbialHighlights: SWSSs were important reservoirs for opportunistic and enteric pathogens. SWSSs could promote the microbial regrowth and colonization of pathogens. Potential pathogenic Legionella had a higher detection frequency in local SWSSs. Water temperature and chlorine residuals drove the changes of microbiomes. Abstract: Secondary water supply systems (SWSSs) are characterized by long water stagnation and low levels of chlorine residuals, which may pose a high microbial risk to terminal users. In this study, the SWSSs of 12 residential neighborhoods in a metropolitan area of 5 million people in southeastern China were seasonally investigated to assess their microbial risks by determining more than 30 physicochemical and biological parameters. Although the microbiological quality of SWSS water met the requirements of the standards for drinking water quality of China, it did deteriorate in various aspects. The heterotrophic plate counts with R2A media were high (> 100 CFU/mL) in some SWSS tank and tap water samples. Propidium monoazide (PMA)-qPCR revealed a one magnitude higher abundance of viable bacteria in the tank and tap water samples (average 10 3.63±1.10 and 10 3.65±1.25 gene copies/mL, respectively) compared with the input water samples, and Enterococcus, Acanthamoeba, and Hartmannella vermiformis were only detected in the tanks. In particular, the high detection frequency of Legionella in 35% tank and 21% tap water samples suggested it is a supplementary microbial safety indicator in SWSSs. The microbial regrowth potential was more obvious in summer, and Illumina sequencing also demonstrated distinct seasonal changes in the relative abundance of bacterial gene sequences at the genus level. Turbidity and residual chlorine were closely connected with total bacterial biomass, and the latter seemed responsible for microbial community structure alteration. The extremely low chlorine residuals associated with a high abundance of total bacteria (as high as 10 6.48 gene copies/mL) and Legionella (as high as 10 6.71 gene copies/100 mL) in the closed valve tanks highlighted the high microbial risk increased by mishandling the operation of SWSSs. This study found that SWSSs possessed a higher microbial risk than the drinking water network, which suggested that the frequency and scope of monitoring the microbial risk of SWSSs in megacities should be strengthened for the purpose of waterborne epidemic disease prevention and control. Graphical Abstract: Image, graphical abstract … (more)
- Is Part Of:
- Water research. Volume 205(2021)
- Journal:
- Water research
- Issue:
- Volume 205(2021)
- Issue Display:
- Volume 205, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 205
- Issue:
- 2021
- Issue Sort Value:
- 2021-0205-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-15
- Subjects:
- Secondary water supply systems -- Microbial risk -- Water Stagnation -- Residual chlorine -- PMA-qPCR -- Illumina sequencing
Water -- Pollution -- Research -- Periodicals
363.7394 - Journal URLs:
- http://catalog.hathitrust.org/api/volumes/oclc/1769499.html ↗
http://www.sciencedirect.com/science/journal/00431354 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.watres.2021.117690 ↗
- Languages:
- English
- ISSNs:
- 0043-1354
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9273.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19638.xml