Accuracy of a new instrument for noninvasive evaluation of pulse wave velocity: the Arterial sTiffness faitHful tOol aSsessment project. Issue 11 (13th November 2021)
- Record Type:
- Journal Article
- Title:
- Accuracy of a new instrument for noninvasive evaluation of pulse wave velocity: the Arterial sTiffness faitHful tOol aSsessment project. Issue 11 (13th November 2021)
- Main Title:
- Accuracy of a new instrument for noninvasive evaluation of pulse wave velocity: the Arterial sTiffness faitHful tOol aSsessment project
- Authors:
- Leone, Dario
Buraioli, Irene
Mingrone, Giulia
Lena, Davide
Sanginario, Alessandro
Vallelonga, Fabrizio
Tosello, Francesco
Avenatti, Eleonora
Cesareo, Marco
Astarita, Anna
Airale, Lorenzo
Sabia, Luca
Veglio, Franco
Demarchi, Danilo
Milan, Alberto - Abstract:
- Abstract : Supplemental Digital Content is available in the text Abstract : Background: Large artery stiffness, assessed by carotid--femoral pulse wave velocity (cfPWV), is a major risk factor for cardiovascular events, commonly used for risk stratification. Currently, the reference device for noninvasive cfPWV is SphygmoCor but its cost and technically challenging use limit its diffusion in clinical practice. Aim: To validate a new device for noninvasive assessment of cfPWV, ATHOS (Arterial sTiffness faitHful tOol aSsessment), designed in collaboration with the Politecnico di Torino, against the reference noninvasive method represented by SphygmoCor. Methods: Ninety healthy volunteers were recruited. In each volunteer, we assessed cfPWV, using SphygmoCor (PWVSphygmoCor ) and ATHOS (PWVATHOS ) devices in an alternate fashion, following the ARTERY Society guidelines. The accuracy was assessed by Bland--Altman plot, and reproducibility was assessed by interoperator correlation coefficient (ICC). Results: Mean PWVATHOS and mean PWVSphygmoCor were 7.88 ± 1.96 and 7.72 ± 1.95 m/s, respectively. Mean difference between devices was 0.15 ± 0.56 m/s, with a high correlation between measurements ( r = 0.959, P < 0.001). Considering only PWV values at least 8 m/s ( n = 30), mean difference was 0.1 ± 0.63 m/s. The ICC was 97.7% with ATHOS Conclusion: ATHOS showed an excellent level of agreement with SphygmoCor, even at high PWV values, with a good reproducibility. Its simplicity ofAbstract : Supplemental Digital Content is available in the text Abstract : Background: Large artery stiffness, assessed by carotid--femoral pulse wave velocity (cfPWV), is a major risk factor for cardiovascular events, commonly used for risk stratification. Currently, the reference device for noninvasive cfPWV is SphygmoCor but its cost and technically challenging use limit its diffusion in clinical practice. Aim: To validate a new device for noninvasive assessment of cfPWV, ATHOS (Arterial sTiffness faitHful tOol aSsessment), designed in collaboration with the Politecnico di Torino, against the reference noninvasive method represented by SphygmoCor. Methods: Ninety healthy volunteers were recruited. In each volunteer, we assessed cfPWV, using SphygmoCor (PWVSphygmoCor ) and ATHOS (PWVATHOS ) devices in an alternate fashion, following the ARTERY Society guidelines. The accuracy was assessed by Bland--Altman plot, and reproducibility was assessed by interoperator correlation coefficient (ICC). Results: Mean PWVATHOS and mean PWVSphygmoCor were 7.88 ± 1.96 and 7.72 ± 1.95 m/s, respectively. Mean difference between devices was 0.15 ± 0.56 m/s, with a high correlation between measurements ( r = 0.959, P < 0.001). Considering only PWV values at least 8 m/s ( n = 30), mean difference was 0.1 ± 0.63 m/s. The ICC was 97.7% with ATHOS Conclusion: ATHOS showed an excellent level of agreement with SphygmoCor, even at high PWV values, with a good reproducibility. Its simplicity of use could help increase clinical application of PWV assessment, improving patients' cardiovascular risk stratification. … (more)
- Is Part Of:
- Journal of hypertension. Volume 39:Issue 11(2021)
- Journal:
- Journal of hypertension
- Issue:
- Volume 39:Issue 11(2021)
- Issue Display:
- Volume 39, Issue 11 (2021)
- Year:
- 2021
- Volume:
- 39
- Issue:
- 11
- Issue Sort Value:
- 2021-0039-0011-0000
- Page Start:
- 2164
- Page End:
- 2172
- Publication Date:
- 2021-11-13
- Subjects:
- arterial stiffness -- carotid--femoral pulse wave velocity -- hypertension-mediated organ damage -- noninvasive evaluation -- pulse wave velocity -- risk factor
Hypertension -- Periodicals
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.lww.com/jhypertension/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004872-000000000-00000 ↗
http://www.jhypertension.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/HJH.0000000000002925 ↗
- Languages:
- English
- ISSNs:
- 1473-5598
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5004.510000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19609.xml