Performance of five pulse oximeters to detect hypoxaemia as an indicator of severe illness in children under five by frontline health workers in low resource settings – A prospective, multicentre, single-blinded, trial in Cambodia, Ethiopia, South Sudan, and Uganda. (August 2021)
- Record Type:
- Journal Article
- Title:
- Performance of five pulse oximeters to detect hypoxaemia as an indicator of severe illness in children under five by frontline health workers in low resource settings – A prospective, multicentre, single-blinded, trial in Cambodia, Ethiopia, South Sudan, and Uganda. (August 2021)
- Main Title:
- Performance of five pulse oximeters to detect hypoxaemia as an indicator of severe illness in children under five by frontline health workers in low resource settings – A prospective, multicentre, single-blinded, trial in Cambodia, Ethiopia, South Sudan, and Uganda
- Authors:
- Baker, Kevin
Petzold, Max
Mucunguzi, Akasiima
Wharton-Smith, Alexandra
Dantzer, Emily
Habte, Tedila
Matata, Lena
Nanyumba, Diana
Okwir, Morris
Posada, Monica
Sebsibe, Anteneh
Nicholson, Jill
Marasciulo, Madeleine
Izadnegahdar, Rasa
Alfvén, Tobias
Källander, Karin - Abstract:
- Abstract: Background: Low blood oxygen saturation (SpO2 ), or hypoxaemia, is an indicator of severe illness in children. Pulse oximetry is a globally accepted, non-invasive method to identify hypoxaemia, but rarely available outside higher-level facilities in resource-constrained countries. This study aims to evaluate the performance of different types of pulse oximeters amongst frontline health workers in Cambodia, Ethiopia, South Sudan, and Uganda. Methods: Five pulse oximeters (POx) which passed laboratory testing, out of an initial 32 potential pulse oximeters, were evaluated by frontline health workers for performance, defined as agreement between the SpO2 measurements of the test device and the reference standard. The study protocol is registered with the Australia New Zealand Clinical Trials Registry (Ref: ACTRrn12615000348550). Findings: Two finger-tip pulse oximeters (Contec and Devon), two handheld pulse oximeters (Lifebox and Utech), and one phone pulse oximeter (Masimo) passed the laboratory testing. They were evaluated for performance on 1, 313 children under five years old by 207 frontline health workers between February and May 2015. Phone and handheld pulse oximeters had greater overall agreement with the reference standard (56%; 95% CI 0.52 - 0.60 to 68%; 95% CI 0.65 - 0.71) than the finger-tip POx (31%; 95% CI 0.26 to 0.36 and 47%; 95% CI 0.42 to 0.52). Fingertip POx performance was substantially lower in the 0–2 month olds; having just 17% and 25%Abstract: Background: Low blood oxygen saturation (SpO2 ), or hypoxaemia, is an indicator of severe illness in children. Pulse oximetry is a globally accepted, non-invasive method to identify hypoxaemia, but rarely available outside higher-level facilities in resource-constrained countries. This study aims to evaluate the performance of different types of pulse oximeters amongst frontline health workers in Cambodia, Ethiopia, South Sudan, and Uganda. Methods: Five pulse oximeters (POx) which passed laboratory testing, out of an initial 32 potential pulse oximeters, were evaluated by frontline health workers for performance, defined as agreement between the SpO2 measurements of the test device and the reference standard. The study protocol is registered with the Australia New Zealand Clinical Trials Registry (Ref: ACTRrn12615000348550). Findings: Two finger-tip pulse oximeters (Contec and Devon), two handheld pulse oximeters (Lifebox and Utech), and one phone pulse oximeter (Masimo) passed the laboratory testing. They were evaluated for performance on 1, 313 children under five years old by 207 frontline health workers between February and May 2015. Phone and handheld pulse oximeters had greater overall agreement with the reference standard (56%; 95% CI 0.52 - 0.60 to 68%; 95% CI 0.65 - 0.71) than the finger-tip POx (31%; 95% CI 0.26 to 0.36 and 47%; 95% CI 0.42 to 0.52). Fingertip POx performance was substantially lower in the 0–2 month olds; having just 17% and 25% agreement. The finger-tip devices more often underreported SpO2 readings (mean difference -7.9%; 95%CI -8.6, -7.2 and -3.9%; 95%CI -4.4, -3.4), and therefore over diagnosed hypoxaemia in the children assessed. Interpretation: While the Masimo phone pulse oximeter performed best, all handheld POx with age-specific probes performed well in the hands of frontline health workers, further highlighting their suitability as a screening tool of severe illness. The poor performance of the fingertip POx suggests they should not be used in children under five by frontline health workers. It is essential that POx are performance tested on children in routine settings (in vivo), not only in laboratories or controlled settings (in vitro), before being introduced at scale. Funding: Bill & Melinda Gates Foundation [OPP1054367]. … (more)
- Is Part Of:
- EClinicalMedicine. Volume 38(2021)
- Journal:
- EClinicalMedicine
- Issue:
- Volume 38(2021)
- Issue Display:
- Volume 38, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 38
- Issue:
- 2021
- Issue Sort Value:
- 2021-0038-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08
- Subjects:
- Childhood pneumonia -- Severe illness -- Low-income country -- Diagnostic aids -- Pulse oximeter -- Health worker performance
Medicine -- Research -- Periodicals
Medical policy -- Periodicals
Clinical Medicine
Health Policy
Public Health
Medical policy
Medicine -- Research
Periodical
Electronic journals
Periodicals
613 - Journal URLs:
- https://www.sciencedirect.com/science/journal/25895370 ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.eclinm.2021.101040 ↗
- Languages:
- English
- ISSNs:
- 2589-5370
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19604.xml