Heart rate variability responses determined by photoplethysmography in people with spinal cord injury. (August 2021)
- Record Type:
- Journal Article
- Title:
- Heart rate variability responses determined by photoplethysmography in people with spinal cord injury. (August 2021)
- Main Title:
- Heart rate variability responses determined by photoplethysmography in people with spinal cord injury
- Authors:
- Henrique Rufino Batista, Luiz
Jorge Ribeiro Domingues, Wagner
de Athayde Costa e Silva, Anselmo
Augusta Thomé Lopes, Kathya
Leopoldina de Castro Amorim, Minerva
Rossato, Mateus - Abstract:
- Highlights: The HRV values measured by PPG are significantly correlated with the values evaluated by the Polar H7 TM method. PPG overestimates HRV values for those with SCI. Smartphone-based PPG can be a viable and inexpensive alternative for assessing HRV in SCI. Abstract: This study aims to evaluate whether the photoplethysmography technique (PPG) can be used as an instrument to assess heart rate variability (HRV) parameters in individuals with spinal cord injury (SCI). Twenty-one subjects (2 tetraplegic, 18 paraplegic and 1 diplegic) participated in the study (37.5 ± 12.3 years, 58.8 ± 15.7 kg and 160.0 ± 21.4 cm). HRV parameters were obtained simultaneously for 5 min with PPG (HRV-4 training TM mobile app) and Polar H7 TM . Although significant correlations between PPG and Polar H7 TM have been found for SDNN (r = 0.508, p = 0.019), RMSSD (r = 0.456, p = 0.038), PNN50 (r = 0.620, p = 0.003) and LF (r = 0.456, p = 0.038) parameters, Bland-Altman analyses of agreement showed that PPG overestimates all HRV parameters (SDNN, Bias = 47.61 ms; RMSSD, Bias = 17.91 ms; PNN50, Bias = 11.52%; LF, Bias = 0.22 Hz; and HF, Bias = 0.18 Hz). These results indicate that the HRV parameters have a correlation between the methods evaluated by PPG and PolarH7 TM . However, caution is recommended when using PPG for HRV analysis in people with spinal cord injury, as the results indicate an overestimation of HRV parameters.
- Is Part Of:
- Biomedical signal processing and control. Volume 69(2021)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 69(2021)
- Issue Display:
- Volume 69, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 69
- Issue:
- 2021
- Issue Sort Value:
- 2021-0069-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08
- Subjects:
- Heart rate variability -- Photoplethysmography and Spinal cord injury -- Assistive technologies -- Autonomic regulation -- Mobile health
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2021.102845 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19614.xml