Improving the efficacy and reliability of rTMS language mapping by increasing the stimulation frequency. Issue 16 (13th August 2021)
- Record Type:
- Journal Article
- Title:
- Improving the efficacy and reliability of rTMS language mapping by increasing the stimulation frequency. Issue 16 (13th August 2021)
- Main Title:
- Improving the efficacy and reliability of rTMS language mapping by increasing the stimulation frequency
- Authors:
- Nettekoven, Charlotte
Pieczewski, Julia
Neuschmelting, Volker
Jonas, Kristina
Goldbrunner, Roland
Grefkes, Christian
Weiss Lucas, Carolin - Abstract:
- Abstract: Repetitive TMS (rTMS) with a frequency of 5–10 Hz is widely used for language mapping. However, it may be accompanied by discomfort and is limited in the number and reliability of evoked language errors. We, here, systematically tested the influence of different stimulation frequencies (i.e., 10, 30, and 50 Hz) on tolerability, number, reliability, and cortical distribution of language errors aiming at improved language mapping. 15 right‐handed, healthy subjects (m = 8, median age: 29 yrs) were investigated in two sessions, separated by 2–5 days. In each session, 10, 30, and 50 Hz rTMS were applied over the left hemisphere in a randomized order during a picture naming task. Overall, 30 Hz rTMS evoked significantly more errors (20 ± 12%) compared to 50 Hz (12 ± 8%; p <.01), whereas error rates were comparable between 30/50 and 10 Hz (18 ± 11%). Across all conditions, a significantly higher error rate was found in Session 1 (19 ± 13%) compared to Session 2 (13 ± 7%, p <.05). The error rate was poorly reliable between sessions for 10 (intraclass correlation coefficient, ICC = .315) and 30 Hz (ICC = .427), whereas 50 Hz showed a moderate reliability (ICC = .597). Spatial reliability of language errors was low to moderate with a tendency toward increased reliability for higher frequencies, for example, within frontal regions. Compared to 10 Hz, both, 30 and 50 Hz were rated as less painful. Taken together, our data favor the use of rTMS‐protocols employing higherAbstract: Repetitive TMS (rTMS) with a frequency of 5–10 Hz is widely used for language mapping. However, it may be accompanied by discomfort and is limited in the number and reliability of evoked language errors. We, here, systematically tested the influence of different stimulation frequencies (i.e., 10, 30, and 50 Hz) on tolerability, number, reliability, and cortical distribution of language errors aiming at improved language mapping. 15 right‐handed, healthy subjects (m = 8, median age: 29 yrs) were investigated in two sessions, separated by 2–5 days. In each session, 10, 30, and 50 Hz rTMS were applied over the left hemisphere in a randomized order during a picture naming task. Overall, 30 Hz rTMS evoked significantly more errors (20 ± 12%) compared to 50 Hz (12 ± 8%; p <.01), whereas error rates were comparable between 30/50 and 10 Hz (18 ± 11%). Across all conditions, a significantly higher error rate was found in Session 1 (19 ± 13%) compared to Session 2 (13 ± 7%, p <.05). The error rate was poorly reliable between sessions for 10 (intraclass correlation coefficient, ICC = .315) and 30 Hz (ICC = .427), whereas 50 Hz showed a moderate reliability (ICC = .597). Spatial reliability of language errors was low to moderate with a tendency toward increased reliability for higher frequencies, for example, within frontal regions. Compared to 10 Hz, both, 30 and 50 Hz were rated as less painful. Taken together, our data favor the use of rTMS‐protocols employing higher frequencies for evoking language errors reliably and with reduced discomfort, depending on the region of interest. Abstract : The use of repetitive transcranial magnetic stimulation (rTMS) for language mapping is still hampered by a limited sensitivity and specificity, by an overall poor reliability and by stimulation‐associated discomfort. We, here, found that increasing the stimulation intensity up to 30 and 50 Hz can improve language mapping results as compared to the most commonly used protocol of 10 Hz rTMS. … (more)
- Is Part Of:
- Human brain mapping. Volume 42:Issue 16(2021)
- Journal:
- Human brain mapping
- Issue:
- Volume 42:Issue 16(2021)
- Issue Display:
- Volume 42, Issue 16 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 16
- Issue Sort Value:
- 2021-0042-0016-0000
- Page Start:
- 5309
- Page End:
- 5321
- Publication Date:
- 2021-08-13
- Subjects:
- brain stimulation -- error rate -- noninvasive -- pain -- picture naming -- speech mapping -- TMS -- tolerability -- virtual lesion
Brain mapping -- Periodicals
611.81 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1097-0193 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/hbm.25619 ↗
- Languages:
- English
- ISSNs:
- 1065-9471
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4336.031000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19613.xml