Biomechanical assessment of healthy and keratoconic corneas (with/without crosslinking) using dynamic ultrahigh-speed Scheimpflug technology and the relevance of the parameter (A1L−A2L). Issue 4 (5th June 2018)
- Record Type:
- Journal Article
- Title:
- Biomechanical assessment of healthy and keratoconic corneas (with/without crosslinking) using dynamic ultrahigh-speed Scheimpflug technology and the relevance of the parameter (A1L−A2L). Issue 4 (5th June 2018)
- Main Title:
- Biomechanical assessment of healthy and keratoconic corneas (with/without crosslinking) using dynamic ultrahigh-speed Scheimpflug technology and the relevance of the parameter (A1L−A2L)
- Authors:
- Fuchsluger, Thomas A
Brettl, Susanne
Geerling, Gerd
Kaisers, Wolfgang
Franko Zeitz, Philipp - Abstract:
- Abstract : Aims: To examine corneal biomechanics in healthy and keratoconic eyes, with or without crosslinking obtained by ultrahigh-speed Scheimpflug measurements (Corvis ST). Methods: One hundred and seventeen eyes were studied in three groups: group 1 (n=39) contained keratoconic eyes without crosslinking. Group 2 (CXL; n=28) comprised keratoconic eyes after crosslinking. These were compared with a control group (n=50 matched healthy eyes). In addition, 10 keratoconus patients, before and after CXL treatment, respectively, were examined. Results: The novel parameter A1L–A2L demonstrated highly significant differences between crosslinked corneas and untreated keratoconic or healthy corneas. Velocity during second applanation (A2V) and deformation amplitude (DA) were significantly increased in crosslinked keratoconic eyes both compared with untreated keratoconic eyes and with healthy controls. Radius at highest curvature also was significant among all groups. Inward applanation length (A1L) was significantly increased in controls, whereas outward applanation length (A2L) was significantly reduced in crosslinked keratoconic eyes compared with both other groups. The follow-up analysis revealed statistically significant changes in pachymetry and intraocular pressure and showed tendencies towards significance in applanation times 1 and 2 and in DA. Conclusions: Both A2V and A2L are viable parameters to discriminate healthy from keratoconic but also crosslinked fromAbstract : Aims: To examine corneal biomechanics in healthy and keratoconic eyes, with or without crosslinking obtained by ultrahigh-speed Scheimpflug measurements (Corvis ST). Methods: One hundred and seventeen eyes were studied in three groups: group 1 (n=39) contained keratoconic eyes without crosslinking. Group 2 (CXL; n=28) comprised keratoconic eyes after crosslinking. These were compared with a control group (n=50 matched healthy eyes). In addition, 10 keratoconus patients, before and after CXL treatment, respectively, were examined. Results: The novel parameter A1L–A2L demonstrated highly significant differences between crosslinked corneas and untreated keratoconic or healthy corneas. Velocity during second applanation (A2V) and deformation amplitude (DA) were significantly increased in crosslinked keratoconic eyes both compared with untreated keratoconic eyes and with healthy controls. Radius at highest curvature also was significant among all groups. Inward applanation length (A1L) was significantly increased in controls, whereas outward applanation length (A2L) was significantly reduced in crosslinked keratoconic eyes compared with both other groups. The follow-up analysis revealed statistically significant changes in pachymetry and intraocular pressure and showed tendencies towards significance in applanation times 1 and 2 and in DA. Conclusions: Both A2V and A2L are viable parameters to discriminate healthy from keratoconic but also crosslinked from non-crosslinked keratoconic corneas. The difference of A1L−A2L could reliably discriminate crosslinked from non-crosslinked and healthy corneas. Follow-up examination in a small cohort allows distinction between crosslinked and untreated keratoconus in follow-up examinations. The difference of A1L-A2L could reliably discriminate crosslinked from non-crosslinked and healthy corneas. Measurements of corneal deformation using dynamic ultrahigh-speed Scheimpflug technology are reproducible and provide useful information about keratoconus assessment and biomechanics. Therefore, the Corvis ST seems to provide useful technology to monitor therapeutic success of crosslinking treatment. … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 103:Issue 4(2019)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 103:Issue 4(2019)
- Issue Display:
- Volume 103, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 103
- Issue:
- 4
- Issue Sort Value:
- 2019-0103-0004-0000
- Page Start:
- 558
- Page End:
- 564
- Publication Date:
- 2018-06-05
- Subjects:
- corvis ST -- keratoconus -- crosslinking -- biomechanics -- diagnostic instrument -- cornea
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2017-311627 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19610.xml