Reliability of Cyclotorsion measurements using Scanning Laser Ophthalmoscopy imaging in healthy subjects: the CySLO study. Issue 4 (1st August 2017)
- Record Type:
- Journal Article
- Title:
- Reliability of Cyclotorsion measurements using Scanning Laser Ophthalmoscopy imaging in healthy subjects: the CySLO study. Issue 4 (1st August 2017)
- Main Title:
- Reliability of Cyclotorsion measurements using Scanning Laser Ophthalmoscopy imaging in healthy subjects: the CySLO study
- Authors:
- Lengwiler, Fabian
Rappoport, Daniel
Jaggi, Gregor P
Landau, Klara
Traber, Ghislaine L - Abstract:
- Abstract : Background/aims: To evaluate inter-rater and intra-rater reliability of objective cyclotorsion measurements obtained in healthy subjects using the Heidelberg Spectralis spectral domain—optical coherence tomography (SD-OCT) device. Methods: In this prospective methodological study, 32 healthy subjects (14 men, 18 women; aged 21–64 years) were enrolled, 31 right eyes were examined and their foveo-papillary angles (FPAs) were measured. The retinal nerve fibre layer (RNFL) programme by Heidelberg Spectralis (Heidelberg Engineering, Heidelberg, Germany) was used to measure cyclotorsion based on the in-built algorithm for the measurement of the FPA on the scanning laser ophthalmoscopy (SLO) image. Repeated scans of the fixating and non-fixating right eye without and with eye tracker each were obtained by three different examiners. Results: The mean FPA measured overall by all three examiners was 6.6°±2.8°. The inter-rater reliability of the measured FPAs using the linear mixed effects model is estimated as rhointer =0.8803. The intra-rater reliability is estimated as rhointra =0.9589. Conclusions: Repeatability of objective cyclotorsion measurements within and between observers using the Heidelberg Spectralis OCT is very high. SD-OCT/SLO imaging is a reliable imaging technique to measure and study cyclotorsion. Clinical trial number: NCT02631369, Results.
- Is Part Of:
- British journal of ophthalmology. Volume 102:Issue 4(2018)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 102:Issue 4(2018)
- Issue Display:
- Volume 102, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 102
- Issue:
- 4
- Issue Sort Value:
- 2018-0102-0004-0000
- Page Start:
- 535
- Page End:
- 538
- Publication Date:
- 2017-08-01
- Subjects:
- Imaging
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2017-310396 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19595.xml